3

Heat Controller, Inc. 

PS-81, 101, 121A

 

Installation, Operation & Maintenance

To prevent injury to the user or other people and property damage, the following  instructions must be
followed. Incorrect operation due to ignoring the instructions may cause harm or damage. 

   Your air  conditioner should be used in such a way 

    that it is protected from moisture. e.g. condensation, 

   splashed water, etc. Do not place or store your air 

   conditioner  where it can fall or be pulled into water 

   or any other liquid. Unplug immediately if water

   enters unit.

   Always transport use and store your air conditioner 

   in a vertical, upright position on a stable, level  

   surface. 

   Turn off the product when not in use.

   Always contact a qualified servicer to make 

   repairs. If the supply cord is damaged it must be 

   repaired by an authorized servicer.

   Keep a clearance of at least 1 ft. (30cm) around 

   the unit, away from walls, furniture and curtains.

   If the air conditioner is knocked over during use, 

   turn off  the unit and unplug from the main power 

   supply immediately.

   

    

   

SAFETY  PRECAUTIONS

!

Always do this

   Do not operate your air conditioner in a damp/

   humid room such as a bathroom or laundry room.

   Do not touch the unit with wet or damp hands or 

   to avoid electrical shock.

   Do not remove any cover panels. 

   Never use this appliance if it is not working properly, 

   or if it has been dropped or damaged.

   Never use the plug to start and stop the unit. Always  

   use the switch on the control panel.

   Do not cover or obstruct the inlet or outlet grilles.

   Do not use hazardous chemicals to clean or allow 

   them to come into contact with the unit. 

   Do not use the unit in the presence of inflammable 

   substances or vapors such as alcohol, insecticides, 

   gasoline, etc.

   Do not use this product for functions other than

   those described in this instruction manual.

Never do this

 Save Energy

Use the unit  in the recommended room size - see carton.
Locate the unit where furniture or other objects cannot obstruct the air flow.
Keep blinds/curtains closed during the sunniest part of the day.
Keep the filters clean.
Keep doors and windows closed to keep cool air in and warm air out.

The air conditioner must be operated within the  temperature range indicated below:

Operating conditions

Safety rules

Suggested tools for window kit installation

1. Screwdriver(medium size Phillips)            

2. Tape measure or ruler 

3. Knife or scissors

4. Saw(In the event that the window kit needs to be cut down in size because 

     the window is too narrow for direct installation)

MODE

ROOM TEMPERATURE

COOL

DRY

O

62-95 F (17-35

O

C)

O

55-95 F (13-35

O

C)

Be sure the electrical service is adequate for the model you have chosen. This information can be found 
on the name/rating plate, which is  located on the side of the cabinet and behind the grille.
To minimize shock and fire hazards, proper grounding is important. Your air conditioner must be used 
in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately 
grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the 
proper receptacle. 

WARNING

For your safety

Do not store or use gasoline or other flammable substances/vapors in the vicinity of this or any other 

appliance.

To avoid fire hazard or electric shock, do not use an extension cord or an adaptor plug. Do not remove 

any prong from the power cord.

WARNING

Electrical Information

IDENTIFICATION  OF  PARTS

Accessories

Check all the accessories are included in the package and please refer to the installation instructions for 

their usage.

PARTS :

PARTS NAME :

Exhaust hose and Apaptor

Window Slider Kit and bolt

 Foam seal

TEMP

AUTO 

COOL

DRY

HEA
T

FAN

HIGH

MED

LOW

MODE

FAN SPEED

SWING

TIMER ON

ECONOMY

ON/OFF

TIMER OFF

RESE

T LOCK

SET TEMPER

ATURE(   C)

        FOLLOW

      

    

   ME

        LED

    DISPLA

Y

ION

TURBO

 Remote Controller and Batteries

 Drain hose and drain hose adaptor

All the illustrations in this manual are for explanation  purposes only. Your air conditioner 

may be slightly different. The actual shape of parts, accessories, unit, etc. shall prevail.

NOTE:

Содержание Comfort-Aire PS-101A

Страница 1: ...h Ave Jackson MI 49203 517 787 2100 www heatcontroller com INSTALLATION OPERATION MAINTENANCE MANUAL Portable Room Air Conditioner PS 81A PS 101A PS 121A French version of this manual is available on...

Страница 2: ...g 15 AIR CONDITIONER FEATURES CARE AND MAINTENANCE TROUBLESHOOTING TIPS OPERATING INSTRUCTIONS INSTALLATION INSTRUCTIONS IDENTIFICATION OF PARTS SAFETY PRECAUTIONS Safety rules 3 Operating conditions...

Страница 3: ...r to avoid electrical shock Do not remove any cover panels Never use this appliance if it is not working properly or if it has been dropped or damaged Never use the plug to start and stop the unit Alw...

Страница 4: ...nces vapors in the vicinity of this or any other appliance To avoid fire hazard or electric shock do not use an extension cord or an adaptor plug Do not remove any prong from the power cord WARNING El...

Страница 5: ...rizontal Louver Blade swings automatically Casters Carrying Handles both sides 1 2 3 4 1 2 3 4 Fig 1 Fig 2 Rear 9 6 7 8 10 11 6 7 8 9 10 11 Upper Air Filter Behind the grille Air Outlet Power cord out...

Страница 6: ...sius To convert from one to the other press and hold the Up and Down buttons at the same time for 3 seconds 3 Used to initiate the AUTO ON start time and AUTO OFF stop time program in conjunction with...

Страница 7: ...tes It indicates that the Auto Start program is initiated Press or hold the UP or DOWN buttons to change the time by 0 5 hour increments up to 10 hours then at 1 hour increments up to 24 hours The con...

Страница 8: ...fully Use the SWING button on the remote controller to stop the louver at a desired angle If the louver is placed in a position which would affect the cooling process of the air conditioner it will au...

Страница 9: ...place any obstacles around the air inlet or outlet of the unit Allow 1ft 3ft 30cm to 100cm of space from the wall with for efficient air conditioning Fig 5 Your window slider kit has been designed to...

Страница 10: ...h of window shorten the adjustable window kit if the width of window is less than 26 5 67 5 cm Open the window sash and place the window slider kit on the window stool Fig 9 3 Cut the foam seal adhesi...

Страница 11: ...the adjustable window kit if the width of window is less than 26 5 67 5 cm Open the window sash and place the window slider kit on the window stool See Fig 13 3 Cut the foam seal adhesive type to the...

Страница 12: ...pages for window kit installation 2 Insert the hook of the Exhaust hose into the hole seat of the air outlet and slide down the Exhaust hose along the arrow direction See Fig 17 for installation IMPOR...

Страница 13: ...t floor Please refer to Fig 18 19 When the water level of the bottom tray reaches a predetermined level Carefully move the unit near a drain location remove the bottom drain plug and let the water dra...

Страница 14: ...ce Installation Insert the upper air filter from upward after cleaning attach the lower air filter on the air inlet grille then reinstall the grille by using the screw 2 Unit cabinet Use a lint free d...

Страница 15: ...doors in the room are not closed There are heat sources inside the room Exhaust air duct is not connected or blocked Temperature setting is too high Air filter is blocked by dust 2 Not cool enough Pl...

Страница 16: ...04 2009 3 2013...

Отзывы: