BHD-G Service Manual 

Portable Dehumidifier with R-410A

 

Heat Controller, Inc.

3

3.  Humidity Set Control

The humidity level can be set within a range of 35%RH (Relative Humidity) to 85%RH (Relative Humidity) in 5% 

increments.

For drier air, press the      

button and set to a lower percent value(%). When the value displays 35%,press 

the       

button again will activate the continuous dehumidifying operation. For damper air, press the     button 

and set a higher percent value(%).

TIMER Set Control

Use the (+) or (-) buttons to set the Auto start and Auto stop time from 0.0 to 24 hours.

4. Fan speed

Control the fan speed. By pressing either High or Normal fan speed. Set the fan control to High for  maximum mois

-

ture removal. When the humidity has been reduced and quieter operation is preferred, set the fan control to Normal.

5. TIMER

Press to initiate the Auto start and Auto stop feature, in conjuction with the      and     keys.

6.  Display

Shows the set % humidity level from 35% to 85% or auto start/stop time (0~24 hours) while setting, then shows 

the actual (+5% accuracy) room % humidity level in a range of 30%RH (Relative Humidity) to 90%RH(Relative 

humidity).

Error Codes:

AS-

 Humidity sensor error--Unplug the unit and plug it back in. If error repeats, call for service.

ES-

 Temperature sensor error-- Unplug the unit and plug it back in. If error repeats, call for service.

P1-

 Unit is defrosting-- Allow the unit time to automatically defrost. The error will clear after the unit self defrosts.

P2- 

Bucket is full-- Empty the bucket and replace in the right position.

CO-

 Continuous dehumidifying mode is selected.

1.5 OUTSIDE DIMENSIONS

Model

Width  

in. (mm)

Height  

in. (mm)

Depth  

in. (mm)

BHD-301-G

13.28” (340)

19.88” (505)

9.96” (253)

BHD-501-G

15.47” (393)

24.49” (622)

12.64” (321)

BHD-651-G

Содержание BHD-301-G

Страница 1: ...Heat Controller Inc 1900 Wellworth Ave Jackson MI 49203 517 787 2100 www heatcontroller com SERVICE MANUAL Portable Dehumidifer Series with R 410A BHD 301 G BHD 501 G BHD 651 G...

Страница 2: ...3 3 Operation with Water Tank 4 3 4 Operation with Continuous drainage 5 3 5 MAINTENANCE 5 4 Electronic function 6 4 1 Powering on the unit 6 4 2 Setting the relative humidity 6 4 3 Continuous Dehumi...

Страница 3: ...a jumper lead between the two 2 live test pins 2 The grounding conductor yellow green should be open 3 Measure the resistance value with an ohm meter between the jumped lead and each exposed metallic...

Страница 4: ...ferred set the fan control to Normal 5 TIMER Press to initiate the Auto start and Auto stop feature in conjuction with the and keys 6 Display Shows the set humidity level from 35 to 85 or auto start s...

Страница 5: ...rd to the proper power recepticable The unit s program will run a self check if it is normal the power indicator flashes at 0 5Hz Press Power button now the unit will start operating under DEHUMIDIFYI...

Страница 6: ...s thinners or other chemical agents to clean the unit as this may damage the unit Do not wash the unit directly under a tap or hose The electrical components inside may be damaged and the unit become...

Страница 7: ...ovide better air circulation When the humidistat senses that the room s actual humidity is 5 higher than the set humidity of 35 in continuous mode the compressor will restart and begin to dehumidify t...

Страница 8: ...r discharge valves reducing the ability of the compressor to pump refrigerant gas This condition can be checked as follows 1 Install a piercing valve on the suction and discharge or liquid line 2 Atta...

Страница 9: ...ogen through the system and unsolder the more distant connection first Filter drier high side process tube etc 5 Replace inoperative component and always install a new filter drier Add dry nitrogen th...

Страница 10: ...gerant charge is extremely critical Measure charge carefully as exact as possible to the nameplate charge 2 The correct method for charging the rotary compressor is to introduce liquid refrigerant int...

Страница 11: ...the pointer then gradually move back to infinity 4 Reverse the leads of the probe and momentarily touch the capacitor terminals The deflection of the pointer should be two times that of the first chec...

Страница 12: ...nd fan motor will shut down and the water full indicator will flash with LED displaying P2 Under this situation all buttons are deactivated After the water is removed the unit will restore operating a...

Страница 13: ...Heat Controller Inc Portable Dehumidifier with R 410A BHD G Service Manual 12 6 3 3 Humidity sensor check 6 3 4 Fail to start or fail to start motor...

Страница 14: ...heck the voltage of P1 P2 on main PCB Replace the main PCB if no voltage Capacitor Discharge capacitor before testing Test capacitor Replace if not within 10 of manufacturer s rating Replace if shorte...

Страница 15: ...er Clean if restricted Condenser and Evaporator Clean if restricted Fan motor Check the fan capacitor and replace if not within 10 of manufacturer s rating Room structure Ensure that the room the unit...

Страница 16: ...BHD G Service Manual Portable Dehumidifier with R 410A Heat Controller Inc 15 7 Wiring Diagram...

Страница 17: ...04 2009 05 2010...

Отзывы: