40
Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev. B • 12/17
9
Gas Information
A. Fuel Conversion
• Make sure the appliance is compatible with available gas
types.
• Conversions must be made by a qualified service
technician using Hearth & Home Technologies specified
and approved parts.
B. Gas Pressure
• Optimum appliance performance requires proper input
pressures.
• Pressure requirements are:
WARNING! Risk of Fire or Explosion!
High pressure
will damage valve. Low pressure could cause explosion.
• Verify inlet pressures. Verify minimum pressures when
other household gas appliances are operating.
• Install regulator upstream of valve if line pressure is
greater than 1/2 psig.
Fire Risk.
Explosion Hazard.
High pressure will damage valve.
• Disconnect gas supply piping BEFORE
pressure testing gas line at test pressures
above 1/2 psig.
• Close the manual shutoff valve BEFORE
pressure testing gas line at test pressures
equal to or less than 1/2 psig.
WARNING
REMOVE 2 SCREWS
Figure 9.1 Base Pan Removal
Gas Pressure
Natural Gas Propane
Butane
Minimum inlet pressure
1.13 kPa
2.75 kPa 2.75 kPa
Maximum inlet pressure
3.40 kPa
3.40 kPa 3.40 kPa
Manifold pressure
.87 kPa
2.40 kPa 2.40 kPa
C. Gas Service Access
Access Through the Valve Assembly
1. Locate and remove the two screws that secure the
base pan to the appliance. See Figure 9.1. Remove
base pan. Retain screws.
Access Through the Control Cavity
The lower access cover panel is removable if finishing
material has not been previously installed. See Section
8.A for removal instructions.
NOTE:
The gas control valve supplied with this product
is approved for a maximum inlet pressure of
3.40 kPa
.
For pressures over
3.40 kPa
, an in line pressure regula
-
tor must be installed upstream from the gas control valve.