9
Heat & Glo • SLR-X-AU-L Owner’s Manual • 2653-981 Rev. B • 5/20
Figure 3.2 General Operating Parts
B. General Operating Parts
C. Fuel Specifications
Figure 3.2 references the general operating parts of the
appliance and the section of this manual in which they are
discussed.
WARNING!
Risk of Fire or Explosion!
Appliance must
be set up for compatible gas type!
• This appliance is designed to operate on either natural
gas, propane or ULPG. Make sure the appliance is
compatible with gas type selected for installation site.
• Conversions must be made by a qualified service
technician using Hearth & Home Technologies specified
and approved parts.
Figure 3.3. Good Faith Wall Surface Temperatures Above Appliance
D. Good Faith Wall Surface/TV Guidelines
NOTICE:
Temperatures listed above are taken with a
temperature measuring probe as prescribed by the test
standard used for appliance certification. Temperatures
on walls or mantels taken with an infrared thermometer
may yield increased temperatures of up to 30
°
F (17
°
C)
degrees or more depending on the thermometer settings
and material characteristics being measured. Use
appropriate finishing materials that are able to withstand
these conditions. For additional finishing guidelines, see
Section 10 in the appliance Installation Manual.
FIXED GLASS ASSEMBLY
SECTION 4.B.
DECORATIVE FRONTS
SECTION 4.B.
HEAT MANAGEMENT OPTIONS
SECTION 3.H
CONTROL CAVITY
SECTION 3.I
CLEAR SPACE
SECTION 3.A.
OPTIONAL ACCESSORIES
SECTION 6.A
MEASUREMENTS FROM
TOP EDGE OF THE OPENING
6 in.
18 in.
24 in.
30 in.
36 in.
48 in.
TO CEILING
42 in.
12 in.
194 °F
APPLIANCE FRONT
FIREPLACE
OPENING
142°F
119°F
110°F
105°F
101°F
98°F
95°F
(90 °C)
(61 °C)
(48 °C)
(43 °C)
(41 °C)
(38 °C)
(37 °C)
(35 °C)
(152 mm)
(305 mm)
(457 mm)
(610 mm)
(762 mm)
(914 mm)
(1067 mm)
(1219 mm)