Heat & Glo • SL-550 / 750 / 950TR-E • 2118-900 Rev. AC • 3/15
56
B. Mantel and Wall Projections
WARNING! Risk of Fire!
Comply with all minimum clear-
ances as speci
fi
ed. Framing closer than the minimums list-
ed must be constructed entirely of noncombustible materi-
als (i.e., steel studs, concrete board, etc.) Failure to comply
could cause
fi
re.
3 FT. MAXIMUM
2-7/8 IN.
MINIMUM
1/2 IN.
MINIMUM
Figure 13.14 Mantel Leg (Acceptable on both sides of opening.)
Figure 13.12 Clearances to Mantels or other Combustibles
above Appliance
5 6
7
8 9
10
3
4
5
12
11
10
9
8
7
6
TOP OF HOOD OR FIREPLACE OPENING
4
12
13
11
32
CEILING
Note
: Clearance from opening
to perpendicular wall.
All measurements are in inches.
5-3/8 IN.
MINIMUM
3 IN.
MINIMUM
UNLIMITED
Figure 13.15 Wall Projection (Acceptable on one side of opening.)
Figure 13.13 Non-Combustible Zone
Models: SL-550TR-E, SL-750TR-E
SL-550TR-IPI-E,
SL-750TR-IPI-E
Note
: Clearance from opening
to perpendicular wall.
1/2 in.
SHEETROCK
3-1/2 in.
1/2 in.
NON-COMBUSTIBLE
BOARD SHIPPED
WITH APPLIANCE
Figure 13.16 Non-Combustible Zone
Models: SL-950TR-E, SL-950TR-IPI-E
NON-COMBUSTIBLE ZONE
1/2 in.
1/2 in. SHEETROCK
OR COMBUSTIBLE
MATERIAL
3-1/2 in.