Heat & Glo Pier-HVB-IPI Скачать руководство пользователя страница 40

Heat & Glo  •  PIER-HVB-IPI, ST-HVB-IPI •  2006-901 Rev. C •  12/07

40

Heat & Glo, a brand of Hearth & Home Technologies Inc.

20802 Kensington Boulevard, Lakeville, MN 55044

www.heatnglo.com

Contact Information

Please contact your Heat & Glo dealer with any questions or concerns.

For the location of your nearest Heat & Glo dealer,

please visit www.heatnglo.com.

- NOTES -

_______________________________________________________________________________

_______________________________________________________________________________

_______________________________________________________________________________

_______________________________________________________________________________

_______________________________________________________________________________

_______________________________________________________________________________

_______________________________________________________________________________

_______________________________________________________________________________

_______________________________________________________________________________

DO NOT DISCARD THIS MANUAL

CAUTION

Important operating and
maintenance instruc-
tions included.

Read, understand and
follow  these instructions
for safe installation and
operation.

Leave this manual with
party responsible for use
and operation.

This product may be covered by one or more of the following patents: (United States) 4593510, 4686807, 4766876, 4793322, 4811534, 5000162,
5016609, 5076254, 5113843, 5191877, 5218953, 5263471, 5328356, 5341794, 5347983, 5429495, 5452708, 5542407, 5601073, 5613487, 5647340,
5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195, 6053165, 6145502, 6170481, 6237588,
6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940,
6748942, 6769426, 6774802, 6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174,
D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending.

Printed in U.S.A. -  Copyright 2007

Содержание Pier-HVB-IPI

Страница 1: ...erials away DO NOT DISCARD THIS MANUAL CAUTION Important operating and maintenance instructions included This appliance may be installed as an OEM installation in manufactured home USA only or mobile home and must be installed in accordance with the manufacturer s instruc tions and the manufactured home construction and safety standard Title 24 CFR Part 3280 or Standard for Installa tion in Mobile...

Страница 2: ... fireplace front READ and UNDERSTAND all instructions carefully before starting the installation FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty Prior to the first firing of the fireplace READ the Using Your Fireplace section of the Owners Guide DO NOT USE this appliance if any part has been under water Immediately CALL a qualified ...

Страница 3: ...m Approvals 18 B Installing Vent Components 25 C Vent Termination 27 Step 4 Positioning Leveling and Securing the Fireplace 30 Step 5 The Gas Control System 30 Step 6 The Gas Supply Line 31 Step 7 Gas Pressure Requirements 31 Step 8 Wiring the Fireplace 32 Step 9 Finishing 35 Step 10 Installing Trim Logs Ember Material 36 Installing the Trim 36 Positioning the Logs 36 Shutter Settings 36 Glass Spe...

Страница 4: ...2006 901 Rev C 12 07 4 Part number list on following page Log Assembly Service Parts Diagram Service Parts Pier HVB IPI Beginning Manufacturing Date June 2003 Ending Manufacturing Date ______ Î 11 12 13 14 15 16 17 7 8 9 10 1 2 3 4 5 6 ...

Страница 5: ...nction Box 4021 013 Y Bracket Junction box 2005 173 N Orifice NG 33C 582 833 Y Orifice LP 50C 582 850 Y Ember Mesh Assembly 2006 008 N Mesh Assembly 2005 033A Y Glass Latch Assembly 386 122A Y Flue Restrictor 385 128 N Fiber Glass Rope 060 455 N Mineral Wool 050 721 N Lava Rock 2005 790 N Pilot Tube 446 301 Y Gasket Assembly Contains Ember Box Orifice and air passage gaskets Touch Up Paint TUP GBK...

Страница 6: ...HVB IPI 2006 901 Rev C 12 07 6 Service Parts Diagram Service Parts ST HVB IPI Beginning Manufacturing Date June 2003 Ending Manufacturing Date ______ Part number list on following page Log Assembly 7 8 12 11 10 9 13 1 2 3 4 5 6 ...

Страница 7: ...LP 50C 582 850 Y Ember Mesh Assembly 2005 008 Y Mesh Assembly 2005 033A Y Glass Latch Assembly 386 122A Y Flue Restrictor 385 128 N Fiber Glass Rope 060 455 N Mineral Wool 050 721 N Lava Rock 2005 790 N Pilot Tube 446 301 Y Gasket Assembly Contains Ember Box Orifice and air passage gaskets Touch Up Paint TUP GBK 12 N Conversion Kit NG NGK MS Y Conversion Kit LP LPK MS Y Pilot Orifice NG 446 505 Y ...

Страница 8: ... 11 Module 593 592 Y 12 Module Wire Assembly 593 590A Y Battery Pack 593 594A Y 3V Adaptor Plug 593 593A Y Stocked at Depot 1 10 IMPORTANT THIS IS DATED INFORMATION When requesting service or replacement parts for your appliance please provide model number and serial number All parts listed in this manual may be ordered from an authorized dealer Valve Assembly Parts List Service Parts Beginning Ma...

Страница 9: ...e with local codes or in the absence of local codes with the National Electric Code ANSI NFPA No 70 in the United States or to the CSAC22 1 Canadian Electric Code in Canada These models may be installed in a bedroom or bed sitting room in the U S A and Canada 1Approvals and Codes High Altitude Installations U L Listed gas appliances are tested and approved with out requiring changes for elevations...

Страница 10: ... read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OB STRUCTIONS Inspection The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installa tion unless upon inspection the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5 08 2 a...

Страница 11: ...e maximum safety and benefit Failure to follow these instructions will void the own er s warranty and may present a fire hazard The Heat Glo Warranty will be voided by and Heat Glo disclaims any responsibility for the following actions Installation of any damaged fireplace or vent system component Modification of the fireplace or direct vent system Installation other than as instructed by Heat Glo...

Страница 12: ... ACCESS GAS LINE ACCESS 34 3 4 882mm 4 1 16 102mm 4 1 2 114mm 4 3 4 121mm 2 5 16 58mm 37 7 16 950mm 32 5 16 820mm 21 533mm 42 1067mm 17 15 16 455mm 24 610mm 21 533mm 5 1 4 133mm 1 2 13mm 2 12 306mm Ø8 204mm 8 1 2 216mm REAR VENT COLLARS ELECTRICAL ACCESS GAS LINE ACCESS GAS CONTROLS LABELS SIDE GLASS DOOR TOP STANDOFFS TOP VENT COLLARS ...

Страница 13: ...mm 42 1067mm 32 5 16 820mm 21 533mm 36 3 16 919mm 2 5 16 58mm 4 3 4 121mm 4 1 16 102mm 4 1 2 114mm ELECTRICAL ACCESS GAS LINE ACCESS 12 305mm 4 1 2 114mm 2 9 16 64mm 24 610mm 8 1 2 216mm 34 3 4 882mm Ø8 204mm Ø8 204mm REAR VENT COLLARS ELECTRICAL ACCESS GAS LINE ACCESS GAS CONTROLS LABELS SIDE GLASS DOOR TOP STANDOFFS TOP VENT COLLARS ...

Страница 14: ...n Note Refer to Figure 4B for dimensions and appliance locations if installing a Pier HVB unit with a Catalina shelf and or marble package Note Refer to the Catalina installation instruction included with kit for assembly and installation Figure 4B 50 1 2 in 34 1 2 in 7 in 47 1 2 in 45 1 4 in 13 16 in Marble sizes inches Header 26 x 8 Side headers 45 1 2 x 8 Legs 33 1 2 x 7 45 1 4 in 1149mm FINISH...

Страница 15: ...ing is measured from the top of the unit excluding the standoffs see Figures 37 38 The distance from the unit to combustible construction is to be measured from the unit outer wrap surface to the com bustible construction NOT from the screw heads that se cure the unit together WARNING FRAMING DIMENSIONS ASSUME USE OF 1 2 INCH THICK WALL COVERING MATERIALS ON EXTERIOR OF FRAMING ONLYAND NO SHEETROC...

Страница 16: ... X 4 lumber or heavier Model A B C D E PIER HVB IPI 42 1 8 42 1 2 23 35 3 4 48 ST HVB IPI 47 5 8 42 1 2 23 35 3 4 48 Figure 5 Framing Dimensions NOTE DIMENSIONS SHOWN IN INCHES Shows center of 10 x 12 vent framing holes for top and rear venting The center of the hole is one inch 25 4mm above the center of the horizontal vent pipe ...

Страница 17: ... 1 4 INCHES AT EACH JOINT Figure 6 DVP Series Direct Vent Component Specifications 5 inch inner pipe 8 inch outer pipe DVP90ST 12 9 16 11 1 4 7 1 4 1 1 4 TYP 1 2 TYP 8 9 16 DVP36 DVP48 48 24 36 4 6 DVP4 DVP6 12 DVP12 2 MIN DVP12A 12 3 16 MAX DVP24 9 7 8 45 0O 10 1 4 DVP45 14 1 4 ...

Страница 18: ...n used Identifying Vent Components The vent systems installed on this gas fireplace may in clude one two or three 90 elbow assemblies The rela tionships of vertical rise to horizontal run in vent configura tions using 90 elbows MUST BE strictly adhered to The rise to run relationships are shown in the venting drawings and tables Refer to the diagrams on the next several pages NOTE Two 45 elbows ma...

Страница 19: ...into two pieces Do this by bending the part back and forth until it breaks see Figure 10 1 2 3 4 5 SETTINGS 1 2 3 4 5 4 Center the Flue Restrictor on vent and secure in place using two self tapping screws see Figure 11 STRAIGHT OUT HORIZONTAL VENTING H Max Run 24 610 mm Figure 12 V CAP H 3 Match the amount of vertical in the system with the chart to find the appropriate position to set the Flue Re...

Страница 20: ...X 610mm 2 MIN 610mm 4 MAX 1 22m 3 MIN 914mm 6 MAX 1 83m 4 MIN 1 22m 8 MAX 2 4m 5 MIN 1 5m 10 MAX 3 0m 6 MIN 1 83m 12 MAX 3 6m V H 50 MAX 15 2m NATURAL GAS VENTING WITH ONE 90 ELBOW V FT H FT 900 Elbow on top 2 5 MAX 64mm 1 MIN 305mm 3 MAX 914mm 2 MIN 610mm 6 MAX 1 83m 3 MIN 914mm 9 MAX 2 7m 4 MIN 1 22m 12 MAX 3 6m 5 MIN 1 5m 15 MAX 4 5m 6 MIN 1 83m 18 MAX 5 5m V H 50 MAX 15 2m PROPANE VENTING WITH...

Страница 21: ...2 MIN 610mm 4 MAX 1 22m 3 MIN 914mm 6 MAX 1 83m 4 MIN 1 22m 8 MAX 2 4m 5 MIN 1 5m 10 MAX 3 0m 6 MIN 1 83m 12 MAX 3 6m V H H1 50 MAX 15 2m NATURAL GAS VENTING WITH TWO 90 ELBOWS V V1 FT H FT 900 Elbow on top 2 5 MAX 64mm 1 MIN 305mm 3 MAX 914mm 2 MIN 610mm 6 MAX 1 83m 3 MIN 914mm 9 MAX 2 7m 4 MIN 1 22m 12 MAX 3 6m 5 MIN 1 5m 15 MAX 4 5m 6 MIN 1 83m 18 MAX 5 5m V V1 H 50 MAX 15 2m PROPANE VENTING WI...

Страница 22: ...m 2 MIN 610mm 4 MAX 1 22m 3 MIN 914mm 6 MAX 1 83m 4 MIN 1 22m 8 MAX 2 4m 5 MIN 1 5m 10 MAX 3 0m 6 MIN 1 83m 12 MAX 3 6m V H H1 50 MAX 15 2m H H1 12 MAX 3 6m H H1 18 MAX 5 5m NATURAL GAS VENTING WITH TWO 90 ELBOWS V FT H H1 FT 1 MIN 305mm 3 MAX 914mm 2 MIN 610mm 6 MAX 1 83m 3 MIN 914mm 9 MAX 2 7m 4 MIN 1 22m 12 MAX 3 6m 5 MIN 1 5m 15 MAX 4 5m 6 MIN 1 83m 18 MAX 5 5m V H H1 50 MAX 15 2m PROPANE VENT...

Страница 23: ...X 1 22m 3 MIN 914mm 6 MAX 1 83m 4 MIN 1 22m 8 MAX 2 4m 5 MIN 1 5m 10 MAX 3 0m 6 MIN 1 83m 12 MAX 3 6m V V1 H H1 H2 50 MAX 15 2m H H1 H2 12 MAX 3 6m H H1 H2 18 MAX 5 5m NATURAL GAS VENTING WITH THREE 90 ELBOWS V V1 FT H H1 FT 1 MIN 305mm 3 MAX 914mm 2 MIN 610mm 6 MAX 1 83m 3 MIN 914mm 9 MAX 2 7m 4 MIN 1 22m 12 MAX 3 6m 5 MIN 1 5m 15 MAX 4 5m 6 MIN 1 83m 18 MAX 5 5m V V1 H H1 50 MAX 15 2m PROPANE VE...

Страница 24: ...4mm 2 MIN 610mm 6 MAX 1 83m 3 MIN 914mm 9 MAX 2 7m 4 MIN 1 22m 12 MAX 3 6m 5 MIN 1 5m 15 MAX 4 5m 6 MIN 1 83m 18 MAX 5 5m V V1 H H1 50 MAX 15 2m PROPANE VENTING WITH THREE 90 ELBOWS V V1 FT H H1 FT 900 Elbow on top 2 MAX 610mm 1 MIN 305mm 2 MAX 610mm 2 MIN 610mm 4 MAX 1 22m 3 MIN 914mm 6 MAX 1 83m 4 MIN 1 22m 8 MAX 2 4m 5 MIN 1 5m 10 MAX 3 0m 6 MIN 1 83m 12 MAX 3 6m V V1 H H1 50 MAX 15 2m H H1 12 ...

Страница 25: ...it horizontally the elbow cover plate must first be removed from the unit see Figure 20 The elbow can be removed from the unit by aligning the seams of the elbow to the arrows on the surrounding heat shield see Figure 21 Position the elbow in the vertical position Snap in place with the starting collar Replace the elbow cover plate aligning it with the elbow and secure in place with the 8 screws P...

Страница 26: ...e preceding component s vertical axis If an el bow does not end up in a locked position with the pre ceding component attach with a minimum of two 2 sheet metal screws NOTE There must be NO INSULATION or other combustibles inside the framed firestop opening 10 12 INTERIOR WALL SHIELD For Vertical Runs One ceiling firestop is REQUIRED at the hole in each ceiling through which the vent passes To ins...

Страница 27: ...attach and secure the termination to the last section of horizontal vent refer to the Cinch Pipe and Termination Cap installation instructions Push on and snap lock as described at the beginning of the Installing Vent Components section The termination kit should pass through the wall firestops from the exterior of the building Adjust the termination cap to its final exterior position on the build...

Страница 28: ...ly on one side and with an overhang are permitted with the dimensions specified for vinyl or non vinyl siding and soffits 1 There must be 3 feet minimum between termination caps 2 All mechanical air intakes within 10 feet of a termination cap must be a minimum of 3 feet below the termination cap 3 All gravity air intakes within 3 feet of a termination cap must be a minimum of 1 foot below the term...

Страница 29: ...Y IN THE INTER EST OF SAFETY SEE THE FOLLOWING DIAGRAM FOR MINIMUM HEIGHTS PROVIDED THE TERMI NATION CAPISAT LEAST 20 INCHES FROMAVER TICAL WALLAND 2 FEET BELOW AHORIZONTAL OVERHANG NOTE This also pertains to vertical vent systems in stalled on the outside of the building Roof Pitch H min ft flat to 6 12 1 0 over 6 12 to 7 12 1 25 over 7 12 to 8 12 1 5 over 8 12 to 9 12 2 0 over 9 12 to 10 12 2 5 ...

Страница 30: ...base pan for securing the unit to the floor The diagram below shows how to properly position level and secure the fireplace Figure 31 Proper Positioning Leveling and Securing of a Fireplace Step 5 The Gas Control System WARNING THIS UNIT IS NOT FOR USE WITH SOLID FUEL Figure 32 Gas Control System IPI PILOT WARNING CONTINUOUS 110 120 VAC SERVICE MUST BE WIRED DIRECTLY TO THE FIREPLACE JUNCTION BOX ...

Страница 31: ...not exceed 2 in diameter and it does not penetrate the actual firebox Open the fireplace lower grille insert the gas supply line through the gas line hole and connect it to the shut off valve When attaching the pipe support the control so that the lines are not bent or torn After the gas line installation is complete all connec tions must be tightened and checked for leaks with a commercially avai...

Страница 32: ...ntain correct polarity when wiring the junc tion box Figure 34 Intermittent Pilot Ignition IPI Wiring Diagram Operation using Battery Power This fireplace has an optional battery operation The sys tem is fully functional with the use of two D size batteries without ordinary 110 120 VAC power Wiring to the battery pack should be left disconnected in order to conserve battery life In the case of a l...

Страница 33: ...f fireplace you have see Figure 36 Figure 35 Fan Wiring Diagram Optional Accessories Optional fan and remote control kits require that 110 120 VAC be wired to the factory installed junction box before the fireplace is permanently installed NOTE If any of the original wire as supplied with the appliance must be replaced it must be replaced with the type 105o C rated wire FAN JUNCTION BOX SPEED CONT...

Страница 34: ...all switch as shown At the appliance connect the black hot white neutral and green ground wires to the junction box as shown Add a 1 4 inch insulated female connector to the red switch leg wire route it through the knockout in the face of the junction box and connect to the top fan switch connector 1 4 inch male as shown Figure 37 Junction Box Wired to Wall Switch Wall Switch Installation for Fan ...

Страница 35: ...bustible material such as wood can be placed on the top edge and sides of the fireplace Hearth Extensions A hearth extension may be desirable for aesthetic reasons However ANSI or CAN CGA testing standards do not require hearth extensions for gas fireplace appliances Figure 40 Sealant Material ST HVB IPI TOP EDGE SIDE EDGE PIER HVB IPI and L RCOR HVB IPI TOP EDGE SIDE EDGE 0 GAP 0 GAP Figure 39 NO...

Страница 36: ...s with this manual If sooting occurs the logs might need to be repositioned slightly to avoid excessive flame impingement Step 10 Installing Trim Logs Ember Material Glass Specifications Model Type PIER HVB IPI TEMPERED ST HVB IPI TEMPERED Heat Glo fireplaces manufactured with tempered glass may be installed in hazardous locations such as bathtub enclosures as defined by the CPSC The tempered glas...

Страница 37: ...er of ember material Save the remaining ember materials for use during fire place servicing The bag of embers provided is sufficient for 3 to 5 applications Replace the glass door and a front trim door on the unit Figure 42 Placement of the Ember Material Optional Ember Light Kit Emberkit MS Ember Light Bulb Replacement In the lower gas valve compartment you will find three ac cess panels for the ...

Страница 38: ...obstructions Before lighting the fireplace double check the unit for possible obstructions that could be blocking the vent ter minations or the front grilles Double check for faulty components Any component that is found to be faulty MUST BE re placed with an approved component Tampering with the fireplace components is DANGEROUS and voids all war ranties A small amount of air will be in the gas s...

Страница 39: ...Cleaning Flame Sensor Rod IPI Systems Frequency Periodically By Qualified service technician Task Make a visual check of the straight flame sensor rod Use emery cloth to carefully remove any existing white film or deposits Checking Flame Patterns Flame Height Frequency Periodically By Qualified service technician Home owner Task Make a visual check of your fireplace s flame patterns Make sure the ...

Страница 40: ...____________________________________________________ _______________________________________________________________________________ DO NOT DISCARD THIS MANUAL CAUTION Important operating and maintenance instruc tions included Read understand and follow these instructions for safe installation and operation Leave this manual with party responsible for use and operation This product may be covered ...

Отзывы: