Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 R14 • 11/14
39
Recommended operating procedures
Ignite the fire in the appliance with the variable speed con
-
trol switch in an "ON" position. The fan will automatically turn
on when the temperature sensor switch closes at approxi
-
mately 110 degrees Fahrenheit. Heated air should be deliv
-
ered at the outlet grille. The fan will continue to operate after
the appliance is turned OFF until the sensor switch opens.
Various conditions (such as appliance model, type of
appliance installation, outside air temperature vs. inside air
temperature) can contribute to the length of the time the
blower remains on after the appliance is turned OFF.
The
blower can be turned off manually with the speed control
switch.
BLUE
VARIABLE
SPEED SWITCH
TEMPERATURE
SENSOR SWITCH
JUNCTION BOX
Figure 8.28 Blower Wiring Diagram
WARNING! Risk of Shock!
Replace damaged wire with type 105º C rated wire. Wire must have high temperature insulation.