23
HIGH WIND TERMINATION
CAP #SLK-991DA
TOP ADAPTOR
THREE SHEET
METAL SCREWS
FLASHING
9.
Attach the flex to the retro connector. Use three sheet
metal screws to attach the flex liner to the connector
(Fig
ure 5.29
). Mount the retro connector to the masonry
wall using masonry bolts. Redrill larger holes on
connector as needed. Be careful to ensure that the
connector is centered in the opening and the mounting
holes line up with the masonry wall.
6 in. (152 mm) DIAMETER
OPENING IN MASONRY WALL
RETRO
CONNECTOR
THREE MASONRY BOLTS
(NOT INCLUDED)
FOUR MASONRY BOLTS
(NOT INCLUDED)
RETRO
CONNECTOR
WALL
THIMBLE COVER
10. Slide wall thimble cover over retro connector and
secure with masonry bolts (Figure 5.30). If you have a
framed wall in front of the masonry, use wood screws
to mount wall thimble cover to framed wall, over retro
connector and 10 in. (254 mm) square framed opening
(Figure 5.25). If needed, add a section of direct vent
pipe to the retro connector in order to extend through
the opening in the wall thimble cover.
Figure 5.28
Figure 5.29
Figure 5.30
11.
The connection between the appliance and the retro
connector may be completed with sections of direct