Figure 13.16 Combustible Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
TOP VIEW
3-1/4 in. Min.
2-3/4
in. Min.
1/2 in.
Min.
Unlimited
1 in.
Max.
FIREPLACE
OPENING
Note:
Clearance from opening to perpendicular wall.
C. Facing Material
• Metal front faces may be covered with non-combustible
materials only.
• Facing and/or fi nishing materials must not interfere with
air fl ow through louvers, operation of louvers or doors,
or access for service.
• Facing and/or fi nishing materials must never overhang
into the glass opening.
• Observe all clearances when applying combustible
materials.
• Seal joints between the fi nished wall and appliance top
and sides using a 300 °F minimum sealant. Refer to
Figure 13.17.
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specifi ed in
this manual. Overlapping materials could ignite and will
interfere with proper operation of doors and louvers.
0 in.
0 in.
0 in.
Finish wall material may be
combustible - Top and Sides
High Temperature Sealant (300° F/149° C min.)
Top and Side Seal Joint
Figure 13.17 Noncombustible Facing Diagram
Figure 13.19 Overlap Fit Door
Figure 13.18 Folio Door and Aero
DOOR
FIT
FINISH MATERIAL
MAXIMUM
THICKNESS
SEE FIGURE
Aero
Inside
Any
13.18
Folio
Inside
Any
13.18
Arcadia
Overlap
1 inch
13.19
Inside
Any
13.20
Halston
Overlap
1 inch
13.19
Inside
1 inch - 2 inch
13.21
Chateau
Overlap
1 inch
13.19
Inside
Any
13.20
Valencia
Overlap
1 inch
13.19
Inside
Any
13.20
Galleria
Overlap
1 inch
13.19
Inside
1 inch - 2 inch
13.21
D. Finishing Material
Only doors certifi ed for use with this appliance model may
be used. Contact your dealer for a list of doors that may
be used. Once you have determined what kind of door
and fi nishing material is going to be used on the fi replace,
you may use the table below which shows the door mod-
els and the fi nishing material thickness allowed. For an
inside fi t there is an available template to assist with siz-
ing the fi nishing material.
Stop fi nishing material fl ush with opening.
FINISHING MATERIAL
4 IN. MAXIMUM THICKNESS
DOOR
FINISHING MATERIAL
4 IN. MAXIMUM THICKNESS
1 in. MAX
FINISHING MATERIAL
(TOP EDGE)
DOOR
FRONT FACE OF FIREPLACE
Finishing materials 1 inch maximum thick.
Stop fi nishing material fl ush with opening.
ST-36TRB-IPI
DOOR
FIT
FINISH MATERIAL
MAXIMUM
THICKNESS
SEE FIGURE
Aero
Inside
Any
13.22
Chateau
Inside
Any
13.22
Arcadia
Inside
Any
13.22
PIER-36TRB-IPI