Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13
B. Mantel and Wall Projections
WARNING! Risk of Fire!
Comply with all minimum clear-
ances to combustibles as speci
fi
ed. Framing closer than the
minimums listed must be constructed entirely of noncom-
bustible materials (i.e., steel studs, concrete board, etc.)
Note:
For non-combustible
fi
replace
fi
nish material (marble,
stone, etc) speci
fi
cations refer to Figure 10.6 and Figure 10.7.
Combustible Mantels
Figure 10.10 Combustible Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
Combustible Mantel Legs Or Wall Projections
Extending Past The Face Of The Fireplace
UNLIMITED
6 IN.
MIN.
2 IN.
MIN.
FIREPLACE
OPENING
4 IN.
MAX.
= ACCEPTABLE
NON-COMBUSTIBLE
MANTEL LEG
ZONE
MEASUREMENTS FROM
TOP EDGE OF THE OPENING
7
8
9
10
11
12
13
31
TO CEILING
9
10
11
12
8
7
6
25
18
Note: For non-combustible
fi
replace
fi
nish material (marble,
stone, etc) speci
fi
cations refer to Section 13.
Note:
All
measurements
in inches.
Non-Combustible Mantels
MEASUREMENTS FROM TOP EDGE OF THE
FIRESCREEN DOOR ASSEMBLY
8
9
10
16
7
6
5
4
1
2
3
4
5
6
12
31
MAX.
MIN.
TO CEILING
1/2
Note:
All
measurements
in inches.
Figure 10.8 Minimum Vertical and Maximum Horizontal
Dimensions of Combustibles
Figure 10.9 Minimum Vertical and Maximum Horizontal
Dimensions of Non-Combustibles