Service Parts

Service Parts Diagram

GRAND-XTS

IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement 
parts for your appliance please provide model number and serial number. All parts listed 
in this manual may be ordered from an authorized dealer.

Stocked 

at Depot

ITEM

DESCRIPTION

COMMENTS

PART NUMBER

Log Set  Assembly  

LOGS-GXT

Y

1

Log 1 

SRV339-701

2

Log 2 

SRV339-702

3

Log 3  

SRV327-703

4

Log 4 

SRV339-704

5

Log 5 

SRV438-724

6

Log 6

SRV327-705

7

Log 7

SRV571-707

8

Fireplace Termination Assembly

319-213A

9

Burner

339-176A

Y

10

Grate Assembly

339-360A

11

Base Pan

339-124

12

Control Panel

319-129

13

Flame Control Knob

571-533

Y

14

Piezo Ignitor

291-513

Y

15

Glass Door Assembly  

GLA-339

Y

16

Pilot Control Knob

571-534

Y

17

Rheostat Knob

100-512

Y

18

On/Off Rheostat 

319-510A

Y

19

Junction Box  

040-250A

Y

20

Blower

GFK-160A

Flex Pipe Handle

438-351

Glass Latch Assembly

386-122A

Y

Mineral Wool 

050-721

Orifi ce NG (#32C)

582-832

Y

Orifi ce LP (#51C)

582-851

Y

Pilot Tube

SRV485-301

Y

Thermocouple

2103-511

Y

Thermopile

2103-512

Y

Touch Up Paint  

203-9

Conversion Kit NG 

NGKS-GXT

Y

Conversion Kit LP 

LPKS-GXT

Y

Pilot Orifi ce NG 

2103-116

Y

Pilot Orifi ce LP 

2103-117

Y

Regulator NG

230-1570

Y

Regulator LP

230-1520

Y

Additional service part numbers appear on following page.

Содержание Grand-XTS

Страница 1: ...indicated on the rating plate Leave this manual with party responsible for use and operation DO NOT DISCARD Important operating and maintenance instructions included Read understand and follow these...

Страница 2: ...appliance can be found on the rating plate usually located in the control area of the appliance Homeowner Reference Information Model Number Heat Glo a of Hearth Home Technologies Inc 20802 Kensington...

Страница 3: ...t Pipe and Appliance A Venting Components 11 B Connecting Vent Pipe 11 C Placing Securing and Leveling the Appliance 12 D Installing Adaptor and Termination Cap 13 8 Gas Information A Fuel Conversions...

Страница 4: ...s of Gas Burn ing Heating Appliances for Manufactured Homes and Recreational Vehicles and Gas Fired Appliances for Use at High Altitudes Models U S or Canada Maximum Input BTU h Minimum Input BTU h Or...

Страница 5: ...MUST comply with local regional state and national codes and regulations Consult insurance carrier local building fire officials or authorities having jurisdiction about restrictions installation insp...

Страница 6: ...s The firebrick refractory glass doors screen rails screen mesh and log grates can be removed from a factory built firebox in order to gain minimum gas insert opening requirements Any smoke shelves sh...

Страница 7: ...ance to all clearance specifications in manual Fire Risk Odor Risk Clearance to combustible material under the insert is 1 4 inch 0 6 cm Use leveling legs to raise insert minimum 1 4 inch above combus...

Страница 8: ...12 to 8 12 1 5 Over 8 12 to 9 12 2 0 Over 9 12 to 10 12 2 5 Over 10 12 to 11 12 3 25 Over 11 12 to 12 12 4 0 Over 12 12 to 14 12 5 0 Over 14 12 to 16 12 6 0 Over 16 12 to 18 12 7 0 Over 18 12 to 20 1...

Страница 9: ...rminations are measured to top of chimney Fire Hazard Explosion Risk Asphyxiation Risk Do NOT connect this gas appliance to a chimney flue serving a separate solid fuel or gas burning appliance May im...

Страница 10: ...olid fuels unless all original parts have been replaced and the fireplace re approved by the authority having jurisdiction F Remote Control The receiver for the remotes must be installed BETWEEN the b...

Страница 11: ...LAR INLET AIR STARTING COLLAR STARTING COLLAR BRACKET INLET AIR STARTING COLLAR LOCKING TAB INLET AIR VENT PIPE Figure 7 1 B Connecting Vent Pipe Reference instructions in the termination kit Install...

Страница 12: ...and the face of the existing fireplace surround to which the insert is being installed This insulation is not required but can assist in the prevention of infiltration of cold air and odors from the c...

Страница 13: ...flashing to firebox roof with self tapping screws included in kit Figure 7 4 To help eliminate cold air drafts it may be necessary to place non combustible insulation around the flues as they go thou...

Страница 14: ...2 psig Close the manual shutoff valve BEFORE pressure testing gas line at test pressures equal to or less than 1 2 psig Verify inlet pressures High pressure may cause overfire condition Low pressure...

Страница 15: ...ze check with the local gas utility If installing this appliance at an elevation above 4500 feet in Canada check with local authorities CHECK FOR GAS LEAKS Explosion Risk Fire Risk Asphyxiation Risk C...

Страница 16: ...It is recommended that a 110 VAC junction box be connected for use with fan or remote control See Figure 9 2 for junction box wiring Prevent accidental appliance operation when not attended Unplug or...

Страница 17: ...emote Plug the cord into a convenient outlet An electrician may install an outlet box inside the fireplace Place the outlet in the lower back corner of the fireplace Must use cord supplied CAUTION Lab...

Страница 18: ...IANCE MUST BE REPLACED IT MUST BE REPLACED WITH TYPE 1050 C RATED WIRE JUNCTION BOX VARIABLE SPEED CONTROL TEMPERATURE SENSOR SWITCH WHT GRN BLK BLK 110 120 VAC BLOWER BLOWER RECEPTACLE BLK BLK BLK BL...

Страница 19: ...maximum horizontal dimensions of appliance mantels or other combustible projections above the top front edge of the appliance not the surround 10 10 Finishing Figure 10 1 Clearances to Mantels or othe...

Страница 20: ...Explosion Risk Follow ember placement instructions in manual Do NOT place embers directly over burner ports Replace ember material annually Improperly placed embers interferes with proper burner oper...

Страница 21: ...ld not need to be positioned If the logs have been packaged separately refer to the following instructions 1 1 2 2 5 5 4 4 3 3 6 6 PILOT PILOT BASEPAN BASEPAN BURNER BURNER LOG 1 SRV349 701 Place log...

Страница 22: ...2 SRV349 702 Position log 2 by locating its slot over the tab on the front left of the burner The slot of the left side of log 2 fits over the bar grate Push the left side back so it rests against th...

Страница 23: ...the Y end of log 6 into the cutout on log 4 and its opposite end into the groove on log 2 LOG 5 SRV327 705 Rest log 5 in the cutouts on both log 1 and log 3 as shown The front edge of log 1 should be...

Страница 24: ...t Pull the right end of the log forward until it touches the tab in the base pan LOG 2 SRV339 702 Position log 2 by locating its slot over the tab on the front left of the burner The slot in the left...

Страница 25: ...rate LOG 4 SRV339 704 Nest log 4 in the smooth cut out areas on the left side of log 1 and place the left end on the base pan Pull the left end forward until it touches the tab on the left side of the...

Страница 26: ...left of the knothole in log 1 and on log 3 The front edge of log 1 should be at the top of the hole when looking through the hole in log 6 LOG 7 SRV571 707 Rest log 7 in the smooth area just to the r...

Страница 27: ...s depending on the model An ex ample of the glass latch is shown in Figure 11 5 Supreme XTS To release glass assembly pull the two bottom spring loaded latches forward and allow them to retract away f...

Страница 28: ...mation manual provided with this appliance For assistance or additional information consult a qualified installer service agency or the gas supplier Do NOT use this appliance if any part has been unde...

Страница 29: ...ustion and ventilation air If not installed operated and main tained in accordance with the man ufacturer s instructions this product could expose you to substances in fuel or fuel combustion which ar...

Страница 30: ...e products used in the paint and logs During this break in period it is recommended that some windows in the house be opened for air circulation This will help avoid setting off smoke detectors and he...

Страница 31: ...iance Combustible materials may ignite ISSUE SOLUTIONS Condensation on the glass This is a result of gas combustion and temperature variations As the appliance warms this condensation will disappear B...

Страница 32: ...lame impingement Ensure that the thermocouple connection at the gas valve is fully inserted and tight hand tighten plus 1 4 turn Disconnect the thermocouple from the valve place one millivolt meter le...

Страница 33: ...n tank Check the LP propane tank Refill the fuel tank b Inner vent pipe leaking exhaust gases back into the system Check venting system for damage Replace repair improperly assembled pipe sections c G...

Страница 34: ...assembly with care NOTE Clean glass after initial 3 4 hours operation Longer operation without cleaning glass may cause a permanent white film on glass CAUTION When cleaning glass door Avoid striking...

Страница 35: ...d and repaint as necessary 2 Replace appliance if firebox has been perforated Burner Ignition and Operation 1 Verify burner is properly secured and aligned with pilot or igniter 2 Clean off burner top...

Страница 36: ...eters A 33 1 32 839 29 1 32 737 B 24 1 4 616 20 5 32 512 C 12 1 8 308 10 3 32 256 D 36 7 8 937 32 5 16 821 E 32 813 27 25 32 706 F 14 3 4 375 12 7 16 316 G 27 686 22 23 32 577 H 22 3 4 578 20 1 4 514...

Страница 37: ...t Flex Liner Accessory Kits see Figure 15 3 Flash Damp Zero clearance damper flashing kit for use with LINK DV 30B or LINK DV4 30B liner kits LINK ZC ADP Zero clearance chimney adapter SVRLINK ADP Ada...

Страница 38: ...1 Rev G 9 08 38 Service Parts Diagram C Service Parts SUPREME XTS Beginning Manufacturing Date Aug 2007 Ending Manufacturing Date ______ Part number list on following page Log Set Assembly 1 2 3 4 5 6...

Страница 39: ...Burner 349 176A Y 9 Grate Assemby 327 360A 10 Base Refractory 349 124 11 Control Panel 319 129 12 Piezo Ignitor 291 513 Y 13 Flame Control Knob 571 533 Y 14 Glass Door Assembly GLA 349 Y 15 Pilot Con...

Страница 40: ...01 Rev G 9 08 40 Service Parts Diagram GRAND XTS Beginning Manufacturing Date Aug 2007 Ending Manufacturing Date ______ Service Parts Part number list on following page Log Set Assembly 1 2 3 7 6 4 5...

Страница 41: ...319 213A 9 Burner 339 176A Y 10 Grate Assembly 339 360A 11 Base Pan 339 124 12 Control Panel 319 129 13 Flame Control Knob 571 533 Y 14 Piezo Ignitor 291 513 Y 15 Glass Door Assembly GLA 339 Y 16 Pil...

Страница 42: ...ealer Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 1 Pilot Assembly NG 2103 010 Y Pilot Assembly LP 2103 011 Y 2 Pilot Bracket 319 164 3 Shutter Bracket Assembly 2026 130 Y 4 Valve Plate Gas...

Страница 43: ...ble under this warranty is limited to the purchase price of the product In no event shall HHT be liable for any incidental or consequential damages caused by defects in the product Adjustments regular...

Страница 44: ...ed and approved by HHT in writing This warranty does not apply to non HHT venting components hearth components or other accessories used in conjunction with the installation of this product This warra...

Страница 45: ...686807 4766876 4793322 4811534 5000162 5016609 5076254 5113843 5191877 5218953 5263471 5328356 5341794 5347983 5429495 5452708 5542407 5601073 5613487 5647340 5688568 5762062 5775408 5890485 5931661 5...

Отзывы: