![Heat & Glo GRAND-I35-SP Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/heat-and-glo/grand-i35-sp/grand-i35-sp_owners-manual_2115059032.webp)
Heat & Glo • Grand-I35-C, Grand-I35-SP, Supreme-I30-C, Supreme-I30-SP • 2206-901 Rev. P • 6/14
32
11
11
Finishing
A. Mantel and Wall Projections
WARNING! Risk of Fire!
Comply with all minimum clear-
ances to combustibles as speci
fi
ed. Framing or
fi
nishing
material closer than the minimums listed must be construct-
ed entirely of noncombustible materials (i.e., steel studs,
concrete board, etc).
Clearance to combustible material under the insert is 1/4
inch (6 mm). Clearance from top of
fi
replace opening for
combustibles extending 12 inches max. is 12 inches.
• Use leveling legs to raise insert minimum 1/4 inch (6 mm)
above combustible material or outer wrap of factory built
fi
rebox.
Combustible facings must not extend behind the insert
surround. For non-combustible material speci
fi
cations
refer to section 1.E.
Figure 11.1 Clearances to Mantels or other Combustibles
above
Appliance
12 IN. MIN.
12 IN. MAX.
EXISTING NON-COMBUSTIBLE FACING
10 IN. MIN.
2 IN.
MAX.