19
Heat & Glo • Escape-I35-C, Escape-I30-C • 2201-901 Rev. H • 5/12
Figure 5.2 Fireplace Opening
In addition to these dimensions, also reference
Clearances and Mantel Projections (Section 5.B).
E
FRONT VIEW
D
C
F
A
TOP VIEW
B
G**
H
MINIMUM FIREPLACE SIZE
Location
ESCAPE-I35-C
ESCAPE-I35LP-C
ESCAPE-I30-C
ESCAPE-I30LP-C
Inches
Millimeters
Inches
Millimeters
A
Rear Width
25-1/2
648
21-1/2
546
B
Front Width
35
889
30-1/4
768
C
Glass Opening Width
31-1/2
800
26-3/4
679
D
Glass Opening Height
20
508
18
457
E
Height-Front
24-7/8
632
22-7/8
581
F
Height-Rear
22-1/4
565
20-5/8
524
G**
Unit Depth
18-1/4
464
16-7/8
429
H
Venting Depth
13-3/8
340
12-1/8
308
* Note: If exhaust collar on insert and fi replace damper do not line up, add 4 inches (102 mm) to minimum
fi replace height for bends in vent pipe.
**Unit depth is measured to the back of the surround to give the depth needed for installation.