Heat & Glo • EM-42 • 28324 Rev U • 02/07
6
Location of the
¿
replace and chimney will affect performance.
As shown in Figure 2.1 the chimney should:
• Be installed through the warm airspace enclosed by the
building envelope. This helps to produce more draft,
especially during lighting and die-down of the
¿
re.
• Penetrate the highest part of the roof. This minimizes the
effects of wind turbulence.
• Be located away from trees, adjacent structures, uneven
roof lines and other obstructions.
Offsets can restrict draft so their use should be minimized.
Consider the
¿
replace location relative to
À
oor and ceiling
and attic joists.
Recommended
Location
Marginal
Location
Location
Not
Recommended
Recommended
Location
Multi-level Roofs
Windward
Leeward
Outside Air Intake
Location
Not
Recommended
Figure 2.1
Recommended Chimney Locations