Heat & Glo Lifestyle Collection • Dakota 42-CE • 4036-915 Rev I • 11/07
7
FP
= FIREPLACE OPENING
X
= AIR SUPPLY INLET
= AREA WHERE FIREPLACE IS NOT PERMITTED
O
N
P
R
Q
FP
(See Note 2)
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
Q
MIN
R
MAX
Dakota
3.0 M
2 x Q
ACTUAL
1 additional termination cap
Q + 0.91 M 1 x Q
ACTUAL
2 additional termination caps Q + 1.83 M 2/3 x Q
ACTUAL
3 additional termination caps Q + 2.74 M 1/2 x Q
ACTUAL
R
MAX
= (2 / # caps plus fireplace ) x Q
ACTUAL
D
E
L
FP
A
H
M
X
J or K
I
A
G
F
FP
FP
FP
FP
FP
B
B
B
A =
0 cm . . . . . . . . . clearances above grade,
(See note 1) veranda, porch, deck or
balcony.
B
= 30.5 cm . . . . . . . clearances to window or door
that may be opened, or to
permanently closed window.
91.4 cm . . . . . . . vinyl windows or siding.
D** = 119.3 cm . . . . . . . vertical clearance to unventi-
lated soffit or to ventilated soffit
located above the terminal.
152.4 cm . . . . . . . vinyl clad soffits.
F
= 22.8 cm . . . . . . . clearance to outside corner.
G* = 15.2 cm . . . . . . . clearance to inside corner.
121.9 cm . . . . . . . vinyl windows or siding.
H
= 91.5 cm . . . . . . . not to be installed above a gas
meter/regulator assembly within
91.5 cm horizontally from the
center line of the regulator.
I
= 91.4 cm . . . . . . . clearance to service regulator
vent outlet and electric service.
J
=
22.8 cm . . . . . clearance to non-mechanical air
supply inlet to building or the
combustion air inlet to any other
appliance.
K
=
91.4 cm . . . . . clearance to a mechanical air
supply inlet.
L*** =
2.1 M . . . . . . clearance above paved sidewalk
(See note 1)
or a paved driveway located on
public
property.
M**** =
119.3 cm . . . . . clearance under veranda, porch,
deck, balcony or overhang.
Not allowed: . . . . . . vinyl
N
=
15.2 cm . . . . . non-vinyl siding.
P = 213.3
cm
* 122 cm minimum for vinyl windows or vinyl siding.
** Not allowed for vinyl clad soffits.
*** a fireplace shall not open directly above a sidewalk or paved
driveway which is located between two single family dwellings
and services both dwellings.
**** only permitted if veranda, porch, deck or balcony is fully open
on a minimum of 2 sides beneath the floor, or if the screened
porch guidelines are followed.
Note 1: Local codes or regulations may require different clearances.
Note 2: Termination in an alcove space (spaces open only on one side
and with an overhang) are permitted with the dimensions
specified for vinyl or non-vinyl siding and soffits. 1) There must
be a 0.91 M minimum between terminations or between the
fireplace and termination. 2) All mechanical air intakes within 3.0
M of a termination must be a minimum of 0.91 M below the
fireplace hood. 3) All gravity air intakes within 0.91 M of the
fireplace hood must be a minimum of 2.54 cm below the termina-
tion.
A. Fireplace Minimum Clearances
Figure 4.1 Minimum Clearances
4
4
Fireplace Locations