Framing and Clearances
Note:
•
Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY.
•
Illustrations/diagrams are not drawn to scale.
•
Actual installation may vary due to individual design
preference.
Fire Risk
Provide adequate clearance:
• Around air openings
• To combustibles
• For service access
Locate appliance away from traffi c areas.
A. Selecting Appliance Location
When selecting a location for your appliance it is important to
consider the required clearances to walls (see fi gure 3.1).
Figure 3.1 Appliance Locations
Note: For actual appliance dimensions refer to Sec-
tion 16.
In addition to these framing dimensions, also reference the following sections:
• Clearances and Mantel Projections
(Sections 3.C and 3.D)
• Vent Clearances and Framing
(Section 6).
1/2 IN.
A
C
E
E
B
1/2 IN.
B
D
B
A
WARNING
Model
A
B
C
D
E
Cyclone
Inches
31-1/8
28-5/8
44
16-3/8
12
Millimeters
791
728
1118
416
305