Step 7.    Installing Logs and Ember Material

Positioning the Logs

The logs have been packaged separately. Refer to the
installation instructions that accompany this manual.

 Save

the log instructions with this manual.

If sooting occurs, the logs might need to be repositioned
slightly to avoid excessive flame impingement.

Placing the Ember Material

Two separate bags of ember material are shipped with this
gas appliance. The bag labeled Glowing Ember (050-721)
is standard glowing ember material. To place the ember
material:

Remove the glass door from the unit (see Figure 12).

Figure 12.  Glass Assembly

Place a dime size piece of 

GLOWING EMBER

 mate-

rial near port holes in burner top, sides and front (see
Figure 13).

Space dime size ember pieces about a 1/2 inch apart.
Never press embers into burner ports. Do not cover burner
ports. Place dime size pieces around front and sides of
burner pan.

Save the remaining ember materials for use during fire-
place servicing. The embers provided are sufficient for 2
to 4 applications.

Place 

MYSTIC EMBERS

 over burner surface and around

base of the burner, do not cover any burner port holes.
Can be used on floor of firebox for a realistic ash-bed.

Replace the glass door on the fireplace.

Re-install and latch the decorative front.

Figure 13.  Placement of the Ember Material

Combustible materials 

MUST

NEVER

 overlap onto the front

face.

1. Find the coiled low voltage wires

and ON/OFF switch attached to
outer right side of the insert (see
Figure 14).

2. Disconnect the ON/OFF switch

from the low voltage wire leads,
and insert the ON/OFF switch
through the hole at the upper
right corner of the surround - it
will be retained in the hole.

Step 8.  Installing Trim
Surrounds

Figure 14.

SURROUND

WITH TRIM

FIREBOX

ON/OFF

SWITCH

LOCATING SLOTS

LOCATING TABS

PULL AND RELEASE

CLIPS TO OPEN

EMBER MATERIAL

(TOP SURFACE,

AND FRONT)

BURNER PAN

___________________________________________

___________________________________________

Shutter Settings

Burner

NG

LP

CFX-GRAND-B, FB-GRAND

3/8”

Set

CFX-IN-B, FB-IN

1/2”

Set

Содержание CFX-Grand-B

Страница 1: ...se contact your Heat N Glo dealer with any questions or concerns For the number of your nearest Heat N Glo dealer please call 1 888 427 3973 Printed in U S A Copyright 2002 Heat N Glo a division of He...

Страница 2: ...DERSTAND all instructions carefully before starting the installation FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty Prior to the firs...

Страница 3: ...1 Installing the Vent System 14 Step 2 Positioning Leveling and Securing the Insert 18 Step 3 The Gas Control Systems 18 Step 4 The Gas Supply Line 18 Step 5 Gas Pressure Requirements 19 Step 6 Wiring...

Страница 4: ...t on following page La liste des num ros de pi ce se trouve la page suivante 9 10 11 12 4 Log Set Assembly 5 6 7 8 13 19 20 17 16 21 22 18 15 u 14 NG LP Exploded Parts Diagram GN PL Vue clat e des pi...

Страница 5: ...sembly NG Module de veilleuse GN 485 510A 18 Pilot Assembly LP Module de veilleuse PL 485 511A 19 Glass Tab Right tiquette de Verre Droit 783 133 20 Glass Tab Left tiquette de Verre Gauche 783 134 21...

Страница 6: ...ir l Assembl e de Soupape de Balle 302 302A 17 Valve NG Valve GN 060 522 17 Valve LP Valve PL 060 523 18 Pilot Assembly NG Module de veilleuse GN 485 510A 18 Pilot Assembly LP Module de veilleuse PL 4...

Страница 7: ...uve la page suivante 4 Log Set Assembly 2 1 3 5 6 7 8 9 10 11 12 FB IN SHOWN 20 19 21 22 16 17 18 14 15 NG LP Exploded Parts Diagram GN PL Vue clat e des pi ces Service Parts FB IN CFX IN B u CFX IN B...

Страница 8: ...lve PL 060 523 18 Pilot Assembly NG Module de veilleuse GN 485 510A 18 Pilot Assembly LP Module de veilleuse PL 485 511A 19 Glass Tab Right tiquette de Verre Droit 783 133 20 Glass Tab Left tiquette d...

Страница 9: ...Fl chir l Assembl e de Soupape de Balle 302 320A 17 Valve NG Valve GN 060 522 17 Valve LP Valve PL 060 523 18 Pilot Assembly NG Module de veilleuse GN 485 510A 18 Pilot Assembly LP Module de veilleuse...

Страница 10: ...es or in the absence of local codes with the National Electric Code ANSI NFPA No 70 in the United States or to the CSA C22 1 Canadian Electric Code in Canada These models may be installed in a bedroom...

Страница 11: ...built fireplace in order to gain minimum gas insert opening requirements WARNING Under no circumstances is cutting of sheet metal surfaces allowed for installation If the factory built fireplace has...

Страница 12: ...Height 25 3 4 654 22 1 2 571 5 NOTE If exhaust collar on insert and fireplace damper do not line up add 4 inches 102mm to minimum fireplace height for bends in vent pipe Figure 1 Diagram of insert GA...

Страница 13: ...1 D 30 9 16 776 26 1 16 661 E 23 7 8 606 20 5 8 524 F 18 7 16 468 15 3 16 385 G 25 3 8 644 22 1 8 562 H 24 1 2 622 21 1 4 540 Dimensions in brackets are millimeters Figure 2 Diagram and dimension of a...

Страница 14: ...ars of the unit to the end Vent System Approvals of the last section of vent pipe See dimension V in Figure 4 A vertical vent termination system installed on this model will include one 1 length of 3...

Страница 15: ...CODES SPECIFY MINIMUM CHIMNEY AND OR VENT HEIGHT ABOVE THE ROOF TOP THESE MINIMUM HEIGHTS ARE NECESSARY IN THE INTEREST OF SAFETY SEE THE FOLLOWING DIAGRAM FOR MINIMUM HEIGHTS PROVIDED THE TERMINATION...

Страница 16: ...LLAR ON COLLAR SLIDE PLATE THE INLET AIR PIPE MUST ONLY BE CONNECTED TO THE INLET AIR COLLAR OF THE UNIT AND EITHER ATTACHED TO THE INLETAIRCOLLAROFTHETERMINATIONCAP OR TERMINATED IN THE CHIMNEY TERMI...

Страница 17: ...gasket to insure positive exhaust seal TERMINATION CAP ADAPTOR STAINLESS STEEL ADAPTER FOR EXHAUST MUST BE INSTALLED EXHAUST VENT PIPE SUPPLIED WITH TERMINATION KIT INLET AIR VENT COLLAR LINK DV30 SH...

Страница 18: ...pped air NOTE Consult local building codes to properly size the gas supply line leading to the 1 2 inch 13 mm hook up at the unit This gas fireplace is designed to accept a 1 2 inch 13 mm gas supply l...

Страница 19: ...led by a li censed electrician CAUTION DISCONNECT REMOTE CONTROLS IF AB SENT FOR EXTENDED TIME PERIODS THIS WILL PRE VENT ACCIDENTAL APPLIANCE OPERATION For Standing Pilot Ignition Wiring Appliance Re...

Страница 20: ...Detach flexible liner from back of unit Remove the four screws on the coverplate see Figure 11 Bend up the tabs on the base pan see Figure 10 Place the blower in between the bend up tabs Install and...

Страница 21: ...terials for use during fire place servicing The embers provided are sufficient for 2 to 4 applications Place MYSTIC EMBERS over burner surface and around base of the burner do not cover any burner por...

Страница 22: ...and let it cool completely Remove and clean the glass Replace the glass and run the fireplace for an additional 8 hours This will help to cure the chemicals used in the paint and logs Step 10 Lighting...

Страница 23: ...ompartment fireplace logs and burner areas surrounding the logs Checking Flame Patterns Flame Height Frequency Periodically By Qualified service technician Home owner Task Make a visual check of your...

Отзывы: