Heat & Glo BW36 Скачать руководство пользователя страница 2

4-00

2

30491D

BW36 SERIES WOODBURNING FIREPLACE

Table of Contents 

A.  Listings and Code Approvals..........................................................................................................................3
B.  
Description of the Fireplace System...............................................................................................................3
C.  
Fireplace System Components ......................................................................................................................4
D.  
Pre-Installation Preparation ............................................................................................................................8

1.  Fireplace Locations and Space Requirements.........................................................................................8
2.  
Framing The Fireplace .............................................................................................................................9
3.  
Hearth Extensions ..................................................................................................................................10
4.  
Sidewalls/Surrounds...............................................................................................................................11
5.  
Mantel.....................................................................................................................................................11

E.  Chimney Requirements ................................................................................................................................11

1.  Using Offsets and Returns .....................................................................................................................12
2.  
Chimney Height Requirements ..............................................................................................................13

F.  Step-By-Step Installation of the Fireplace System .......................................................................................14
G.  
Constructing a Chase...................................................................................................................................19

1.  Materials For The Chase........................................................................................................................19
2.  
Installing a Terminal Cap on a Chase-Enclosed Chimney .....................................................................20

H.  Operating Instructions ..................................................................................................................................21

Safety Precautions 

1. Please read these installation instructions com-

pletely before beginning installation procedures.
Failure to follow them could cause a fireplace
malfunction resulting in serious injury and/or prop-
erty damage.

2. Always check your local Building codes prior to

installation.  The installation must comply with all
local, regional, state and national codes and regu-
lations.  

3. An adequate supply of replacement combustion

air from outside the house must be available to
the fire for the fireplace to operate properly.  To
achieve this, an optional outside air kit is highly
recommended.  

In the event the home is unusually tight, the
optional combustion air kit may not provide all the
air required to support combustion. Heat-N-Glo is
not responsible for any smoking or related prob-
lems that may result from the lack of adequate
combustion air.  It is the responsibility of the
builder/contractor to ensure that adequate com-
bustion air has been provided for the fireplace.

4. The BW36 Series woodburning fireplace must be

installed with the Hearth Technologies Inc. (HTI)
SL300 Series chimney system.  

The chimney system must always terminate out-
side the Building.  Be sure to follow all chimney
specifications given in these installation instruc-
tions.

5. NEVER leave children unattended when there is

a fire burning in the fireplace.

6. This fireplace is built for solid fuel only.  DO NOT

use chimney cleaners or flame colorants in your
fireplace.

7. NEVER use gasoline, gasoline type lantern fuel,

kerosene, charcoal lighter fluid, or similar liquids
in this fireplace.  Keep any flammable liquids a
safe distance from the fireplace.

8. The flue damper must be open at all times when

the fireplace is in use.

9. While servicing this fireplace, always shut off any

electricity or gas to the fireplace.  This will prevent
possible electrical shock or burns.  Also, make
sure the unit is completely cooled before servic-
ing.

10. To ensure a safe fireplace system and to prevent

the buildup of soot and creosote, inspect and
clean the fireplace and chimney prior to use and
periodically during the burning season.

PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE.

No one builds a better fire

Содержание BW36

Страница 1: ...on of Hearth Technologies Inc 20802 Kensington Blvd Lakeville MN 55044 BW36 BW36C WOODBURNING FIREPLACE INSTALLATION OPERATING INSTRUCTIONS FOR RESIDENTIAL USE Model BW36 shown 558 900 D 4 00 No one b...

Страница 2: ...may not provide all the air required to support combustion Heat N Glo is not responsible for any smoking or related prob lems that may result from the lack of adequate combustion air It is the respons...

Страница 3: ...EMS IN THIS SYSTEM UNLESS ALLOWED BY THESE INSTALLATION INSTRUCTIONS WILL VOID THE UNDERWRITERS LABORATORIES LISTING AND MAY VOID THE PRODUCT WARRANTY IT MAY ALSO CREATE A HAZARDOUS INSTALLATION READ...

Страница 4: ...24 long SL336 Chimney Section 36 long SL348 Chimney Section 48 long SL3 Chimney Stabilizer SL315 Chimney Offset Return 15 SL330 Chimney Offset Return 30 FS338 Firestop Straight FS339 Firestop 15 FS34...

Страница 5: ...1 71 4 33 4 36 335 8 21 6 385 8 327 8 BW36 BW36C 52 16 4 00 5 30491D GR16 AS8 HEARTH EXTENSIONS GLASS DOORS OUTSIDE AIR KIT STRAIGHT ATTIC INSULATION SHIELD INTEGRAL GRATES BW36 SERIES WOODBURNING FIR...

Страница 6: ...5 8 HTI CAT A B FS338 0 141 2 FS339 15 183 8 FS340 30 23 CHIMNEY SECTIONS CHIMNEY STABILIZER OFFSETS RETURNS SL3 FIRESTOP SPACERS ROOF FLASHING 101 2 Flat to 6 12 Pitch RF370 6 12 to 12 12 Pitch RF371...

Страница 7: ...ECTIONS TR342 ROUND TERMINAL CAP TR344 ROUND TERMINAL CAP WITH STORM COLLAR CT35 CHASE TOP ST375 SQUARE TERMINAL CAP 72 36 2 107 8 BW36 SERIES WOODBURNING FIREPLACE No one builds a better fire 8 Flue...

Страница 8: ...AIR MAY BE DRAWN FROM ATTIC SPACES BASEMENTS OR ABOVE THE ROOF WHERE OTHER HEATING APPLIANCES OR FANS AND CHIMNEYS EXHAUST OR UTILIZE AIR THESE PRECAUTIONS WILL REDUCE THE POSSIBILITY FOR SMOKING OR F...

Страница 9: ...TION LOCALIZED OVERHEATING COULD OCCUR AND A FIRE COULD RESULT Combustible Material Material made of or surfaced with wood compressed paper plant fibers plastics or any material capable of igniting a...

Страница 10: ...4 00 10 30491D Figure 5 Factory Built Hearth Extension Figure 6 Hearth Extension EXAMPLES OF INSULATION USG MICORE CV230 1 2 0 43 REQUIRED THICKNESS K VALUE x 5 THICKNESS OF ALTERNATE MAT INCHES x 5 5...

Страница 11: ...ween Offset Return 6 ft Maximum straight unsupported chimney height above firebox 25 ft 4 SIDEWALLS SURROUNDS 5 MANTEL BW36 SERIES WOODBURNING FIREPLACE CAT A B BW36 36 38 5 8 BW36C 36 38 5 8 93 4 143...

Страница 12: ...The B dimensions that coincide with the A dim ensions represent the required vertical clearance that is needed to complete the offset and return d Read across the chart and find the number of chimney...

Страница 13: ...adverse wind conditions etc may create a need for a taller chimney should smok ing occur 2 CHIMNEY HEIGHT REQUIREMENTS Above the roof line Figure 9 Chimney Height Height of Chimney Components Chimney...

Страница 14: ...assembly Framing that is per pendicular to the fireplace front may contact the side of the firebox assembly at the nailing flanges Slide the metal strips two inches under the front edge of the firepl...

Страница 15: ...e you slip it on the collar Once it is on line it up and secure it with screws to the unit collar through the slots in the elbow Figure 13 Installing the Firestop Spacer STEP 7 Installing an AS8 insul...

Страница 16: ...ctions they must be locked into position with the screws provided using the predrilled holes To prevent gravity from pulling the chimney sections apart the returns and the chimney stabilizers have str...

Страница 17: ...replace sides and the enclosure as well as the fireplace back and the enclosure See Figure 4 for framing details STEP 16 Provisions for an Optional Gas Log Set Knockouts are provided on both sides of...

Страница 18: ...art a structure fire You may only use non combustible material over the black face of the fireplace Refer to Figure 7 for combustible material information Do not cover or restrict any of the louvered...

Страница 19: ...S MUST BE STRICTLY FOLLOWED INCLUDING THE PROVISION OF AIR SPACE CLEARANCE BETWEEN CHIMNEY SYSTEM AND ENCLO SURE TO PROTECT AGAINST AGAINST THE EFFECTS OF CORROSION ON THOSE PARTS EXPOSED TO THE WEATH...

Страница 20: ...RFACES FAILURE TO OPERATE THIS FIREPLACE WITH THE DAMPER IN THE OPEN POSI TION MAY RESULT IN ASPHYXIATION OR A STRUCTURE FIRE CAUTION FIREPLACE OPERATION DOES RE QUIRE AIR DO NOT TAKE AIR FROM OTHER F...

Страница 21: ...volatile fuels that burn at excessive tem peratures may cause the fireplace to operate in an unsafe manner Flammable liquid fuel are explosive and must never be used to start or freshen a fire Heat N...

Страница 22: ...bstructions damage or poor wet fuels can cause smoke spillage CHIMNEY INSPECTION Visually inspect the chim ney internally for obstructions and construction dam age Flue pipe joints and seams must be c...

Страница 23: ...e place and to allow air to pass between the burning logs It is important to keep the fire off the hearth and to allow the ashes to collect beneath the fire thereby forming a layer of additional heat...

Страница 24: ...six 6 months after installation HEAT N GLO shall at its option replace or repair the Glass Doors and any electrical components if operation is faulty This does not include Glass panels broken during...