Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AN • 2/16
52
13
Finishing
A. Mantel and Wall Projections
WARNING! Risk of Fire!
Comply with all minimum clear-
ances as specified. Framing closer than the minimums list-
ed must be constructed entirely of noncombustible materials
(i.e., steel studs, concrete board, etc.)
Figure 13.1 Minimum Vertical and Maximum Horizontal
Dimensions - Combustible or Painted Surfaces
5
10
11
12
2-1/2
13
14
15
16
17
18
19
32
TO CEILING
9
10
11
12
8
7
6
5
4
3
25
18
Measurement from fireplace
opening to bottom of appliance:
= 33-1/2 IN. (6000CLX)
= 35-1/2 IN. (8000CLX)
A
B
INTERIOR WALL
TOP VIEW
MANTEL LEG OR WALL PROJECTIONS
FIREPLACE OPENING
Note:
All
measurements
in inches.
If
A
minimum is ____, then
B
maximum is_____.
A
Inches
2-7/16 3-7/16 4-7/16 5-7/16 6-7/16 7-7/16
Millimeters
62
87
113
138
164
189
B
Inches
1
2
3
4
5
∞
Millimeters
25
51
76
102
127
∞
Note:
Measurement is taken from top of the opening,
NOT the top of the fireplace.
B. Facing Material
• Metal front faces may be covered with non-combustible
materials only.
• Facing and/or finishing materials must not interfere
with air flow through louvers, operation of louvers or
decorative fronts, or access for service.
• Facing and/or finishing materials must never overhang
into the glass opening.
• Observe all clearances when applying combustible
materials.
• Seal joints between the finished wall and appliance top
and sides using a 300ºF minimum sealant. Refer to
Figure 13.4.
WARNING! Risk of Fire! DO NOT
apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specified in
this manual. Overlapping materials could ignite and will
interfere with proper operation of decorative fronts and
louvers.
Mantels - Combustible or Painted Surfaces
Mantel Legs or Wall Projections
Figure 13.3 Clearances to Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
Figure 13.2 Minimum Vertical and Maximum Horizontal
Dimensions - Non-Combustible
Mantels - Non-Combustible
12
13
14
15
16
17
18
19
32
TO CEILING
9
10
11
12
8
7
6
5
4
25
18
Measurement from fireplace
opening to bottom of appliance:
= 33-1/2 IN. (6000CLX)
= 35-1/2 IN. (8000CLX)
Note:
All
measurements
in inches.
Note:
Measurement is taken from top of the opening,
NOT the top of the fireplace.
Combustible or Painted Surfaces
Non-Combustible
If
A
minimum is ____, then
B
maximum is_____.
A
Inches
0 thru 5-7/16
6-7/16
7-7/16
Millimeters
0-138
164
189
B
Inches
4
5
∞
Millimeters
102
127
∞