Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AN • 2/16
22
D. Mantel and Wall Projections
WARNING! Risk of Fire!
Comply with all minimum clear-
ances as specified. Framing or finishing material closer than
the minimums listed must be constructed entirely of non-
combustible materials (i.e., steel studs, concrete board, etc).
Mantels - Combustible or Painted Surfaces
Mantel Legs or Wall Projections
5
10
11
12
2-1/2
13
14
15
16
17
18
19
32
TO CEILING
9
10
11
12
8
7
6
5
4
3
25
18
Measurement from fireplace
opening to bottom of appliance:
= 33-1/2 IN. (6000CLX)
= 35-1/2 IN. (8000CLX)
A
B
INTERIOR WALL
TOP VIEW
MANTEL LEG OR WALL PROJECTIONS
FIREPLACE OPENING
Note:
All measurements in inches.
If
A
minimum is ____, then
B
maximum is_____.
A
Inches
2-7/16 3-7/16 4-7/16 5-7/16 6-7/16 7-7/16
Millimeters
62
87
113
138
164
189
B
Inches
1
2
3
4
5
∞
Millimeters
25
51
76
102
127
∞
Note:
Measurement is taken from top of the
opening, NOT the top of the fireplace.
Figure 5.5 Clearances to Mantel Legs or Wall Projections
(Acceptable on both sides of opening.)
Figure 5.3 Minimum Vertical and Maximum Horizontal
Dimensions - Combustible or Painted Surfaces
Figure 5.4 Minimum Vertical and Maximum Horizontal
Dimensions- Non-Combustible
Mantels - Non-Combustible
12
13
14
15
16
17
18
19
32
TO CEILING
9
10
11
12
8
7
6
5
4
25
18
Measurement from fireplace
opening to bottom of appliance:
= 33-1/2 IN. (6000CLX)
= 35-1/2 IN. (8000CLX)
Note:
All
measurements
in inches.
Note:
Measurement is taken from top of the opening,
NOT the top of the fireplace.
If
A
minimum is ____, then
B
maximum is_____.
A
Inches
0 thru 5-7/16
6-7/16
7-7/16
Millimeters
0-138
164
189
B
Inches
4
5
∞
Millimeters
102
127
∞
Non-Combustible
Combustible or Painted Surfaces