Heat & Glo 6000C-IFT Скачать руководство пользователя страница 23

23

Heat & Glo  •  6000C-IFT, 8000C-IFT Owner’s Manual  •  2502-981 Rev.  J

  

•  12/20  

B.  Frequently Asked Questions - IntelliFire Touch Controls (Optional IFT-RC400) 

Symptom

Possible Cause

Corrective Action

The appliance does not respond to 

commands from the remote control 

display does not light up when 

screen is touched.

Batteries are depleted.

Verify batteries are new. 

Batteries are incorrectly 

oriented.

Verify batteries are installed in correct orientation as shown on 

batteries receptacle. 

The display on remote lights up 

when screen is touched but it does 

not respond to commands.

Touchscreen has lost 

calibration.

Touchscreen needs to be re-calibrated.  Call dealer to have 

screen re-calibrated.

Child Lock is ON.

Check child lock icon located at the top of the remote display. If 

ON, it will show as a ‘locked’ symbol. To unlock, remove battery 

compartment door, locate child lock switch and move to ‘unlock’ 

position.  Verify  child  lock  icon  on  screen  is  now  displayed  in 

‘unlock’ position.

The remote displays the following 

message on-screen:  

No dealer info available

Dealer information not 

programmed into remote.

Remote will still provide all available functions, and appliance is 

fully available for use.  Call dealer to have them program.

The remote displays the following 

message on-screen: 

Call  “Dealer Name & Number” to 

schedule maintenance.

300 hours of use.  Appliance is 

still fully functional.

The appliance has been burning for 300 hours and is due 

for a regular maintenance. Call dealer to have them perform 

maintenance.

The room temperature displayed 

on the remote is either slow or 

quick to respond while operating in 

thermostat mode.

Remote is placed at a very 

short distance or too far away 

from the appliance.

Try to keep the remote close to the appliance but not directly in 

front of it.  The remote acts as the thermostat.

Remote is placed in the path of 

an air draft or vent.

Move the remote away from the direct path of air flow. The 

remote acts as the thermostat.

Flame Modulation

The control system is designed to automatically adjust the 

flame intensity based on the difference between the desired 

room temperature, and actual temperature.  In thermostat 

mode, the hearth appliance will start in HI flame, but as the 

actual temperature approaches the desired set temperature 

on the remote, the flame intensity will automatically decrease.  

Automatic flame modulation will result in more control of the 

temperature, and will cause the appliance to cycle OFF/ON 

less.

The appliance turns OFF the flame 

after extended periods of operation 9 hour safety shutdown timer

This is normal behavior. The appliance has a safety timer that 

will automatically turn OFF the flame after nine hours of 

 

uninterrupted operation.

The remote displays the following 

message on-screen: Fan will turn 

on within 3 minutes

Functioning as intended.

The appliance has a three minute delay timer before the fan is 

turned ON. This allows the air surrounding the appliance to be 

heated before being pushed into the room.

The remote displays the following 

message on-screen: 

“Replace remote batteries."

Low batteries in remote.

Install new batteries in the remote.

The remote is displaying an 

incorrect brand. 

Remote was programmed 

incorrectly.

Call dealer to have them program the remote with correct 

branding. Remote is still fully functional and the appliance is 

unaffected.  

After turning flame ON using 

remote, the flame does not turn 

ON immediately and instead a two 

minute timer is displayed.

Power vent is installed on the 

appliance.

This is expected behavior and the two minute timer is called a 

pre-purge timer. The flame will turn ON at the expiration of the 

timer.

The remote displays the following 

message on-screen: 

“Remote Control Communication 

Error.”

No power to appliance.

Verify home circuit breaker is on and master reset is on (if 

equipped).

Power outage.

Install new batteries in battery backup.

The remote displays the following 

message on -screen:  Sorry your 

appliance did not start.  Try again 

by pressing Flame On.

No power to appliance.  No gas 

to appliance.    Accumulation 

of air in gas line from extended 

period of appliance inactivity.  

Gas control system failure.

Verify that appliance has power and gas.  Verify that the 

appliance accepts flame ON commands with an audible beep, 

and successfully turns flame on within 90 seconds.  If this failure 

persists, contact dealer for service.

Содержание 6000C-IFT

Страница 1: ...r See appliance installation manual for additional Commonwealth of Massachusetts requirements DO NOT store or use gasoline or other flam mable vapors and liquids in the vicinity of this or any other a...

Страница 2: ...z Gaz N NA ATURAL TURAL GAS GAS MADE MADE IN IN USA USA Minimum Minimum Permissible Permissible Gas Gas Supply Supply for for Purposes Purposes of of Input Input Adjustment Adjustment Approved Approve...

Страница 3: ...s 16 B Maintenance Tasks Homeowner 16 C Maintenance Tasks Qualified Service Technician 18 5 Frequently Asked Questions and Troubleshooting A Frequently Asked Questions Appliance 22 B Frequently Asked...

Страница 4: ...ized HHT dealer or distributor whichever occurs earlier However the Warranty coverage shall commence no later than 24 months following the date of Product shipment from HHT regardless of the installat...

Страница 5: ...or handling devices such as exhaust fans or forced air furnaces or other such causes 6 use of fuels other than those specified in the operation instructions 7 installation or use of components not su...

Страница 6: ...ries Inc UL TYPE Direct Vent Heater STANDARD CSA ANSI Z21 88 19 CSA 2 33 19 B Tempered Glass Specifications Hearth Home Technologies appliances manufactured with tempered glass may be installed in haz...

Страница 7: ...the fireplace Consider not using the fireplace when children will be present Contact your dealer for more information or visit www hpba org Product Info Fireplace Stove Heater Glass Fronts Safety To...

Страница 8: ...allation site Conversions must be made by a qualified service technician using Hearth Home Technologies specified and approved parts Figure 3 3 Good Faith Wall Surface Temperatures Above Appliance D G...

Страница 9: ...el to model actual TV temperatures should be validated at the me of each installa on TVs should not be used in situa ons where the actual TV temperature exceeds the manufacturers maximum allowable ope...

Страница 10: ...been removed from inside and or underneath the firebox Review proper placement of logs ember material and or other decorative materials Check the wiring Check the air shutter adjustment Ensure that th...

Страница 11: ...11 Heat Glo 6000C IFT 8000C IFT Owner s Manual 2502 981 Rev J 12 20 F Lighting Instructions IPI...

Страница 12: ...control If this occurs restart the appliance NOTICE Open windows for air circulation during fire place break in Some people may be sensitive to smoke and odors Smoke detectors may activate H Heat Mana...

Страница 13: ...ory installed battery pack is located in the control cavity of the appliance See Figure 3 5 Battery longevity and performance will be affected by long term exposure to the service temperatures of this...

Страница 14: ...to pair the IFT ECM with the IFT ACM if installed and or IFT RC400 and IFT RC150 remote controls See the IFT RC400 or IFT RC150 installation manual for detailed instructions on pairing the IFT ECM wit...

Страница 15: ...s Kit draws heat from your fireplace to an adjacent room in your home up to 20 feet away Optional Heat Out Gas Kit The Heat Out Gas heat management option is available for use with the 6000C IFT and 8...

Страница 16: ...material etc It is imperative that control compartments burners and circulating air passageways of the appliance be kept clean Any safety screen guard or barrier removed for servicing the appli ance...

Страница 17: ...damage and repair as necessary Check that fireplace openings are not blocked Vacuum and dust surfaces Remote Control Frequency Seasonally By Homeowner Tools needed Replacement batteries and remote co...

Страница 18: ...ded Remove all foreign objects Verify unobstructed air circulation Burner Ignition and Operation Frequency Annually By Qualified Service Technician Tools needed Protective gloves vacuum cleaner whisk...

Страница 19: ...me Remove glass assembly from the appliance See Figure 4 1 Note It may be necessary to remove logs in order to clean and inspect the glass refractory Reinstall logs using instructions included in appl...

Страница 20: ...ry grate and valve assemblies This task should be performed by a qualified service technician The refractory grate and base refractory do not need to be removed to service the burner assembly Figure 4...

Страница 21: ...by a qualified ser vice technician The base refractory valve plate and grate do not need to be removed to access the burner assembly The logs and fiber burner top need to be removed to access the burn...

Страница 22: ...s left by oils from the manufacturing process A non abrasive cleaner such as gas fireplace glass cleaner may be necessary See your dealer Metallic noise Noise is caused by metal expanding and contract...

Страница 23: ...etween the desired room temperature and actual temperature In thermostat mode the hearth appliance will start in HI flame but as the actual temperature approaches the desired set temperature on the re...

Страница 24: ...r switch is in ON or REM position Verify AC power available to junction box Verify AC DC adaptor is plugged into junction box and ECM Verify AC DC adaptor output voltage is between 5 7 6 3 Vdc If batt...

Страница 25: ...valve solenoid resistance nominal is 60 ohms If open or shorted replace valve Verify valve inlet pressure is correct for gas type Pilot and main do not light ECM goes into 5 Red 1 Green Lockout Power...

Страница 26: ...our fireplace For safety Install a switch lock or a wall remote control with child protection lockout feature Keep remote controls out of reach of children See your dealer if you have questions Instal...

Страница 27: ...164 701 2 Log 2 SRV2164 702 3 Log 3 SRV2164 703 4 Log 4 SRV2164 704 5 Log 5 SRV2164 705 6 Log 6 SRV2164 706 7 Insulation Board 2166 136 8 Burner Top SRV2166 100 Y 9 Burner NG 2164 007 Y Burner Propane...

Страница 28: ...GS 8C Y 1 Log 1 SRV2168 701 2 Log 2 SRV2168 702 3 Log 3 SRV2168 703 4 Log 4 SRV2168 704 5 Log 5 SRV2168 705 6 Log 6 SRV2168 706 7 Insulation Board 2170 136 8 Burner Top SRV2170 100 Y 9 Burner NG 2168...

Страница 29: ...Bracket 2118 104 18 5 Flex Ball Valve Assembly SRV302 320 Y 18 6 Valve NG SRV2166 302 Y Valve Propane 2166 303 Y 18 7 Male Connector Pkg of 5 303 315 5 Y 18 8 Bulkhead W Tube SRV7000 156 Y 18 9 Jumper...

Страница 30: ...or Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER Exhaust Shield 385 105 Flue Restrictor Qty 2 req 385 328 Gasket Assembly 2166 081 Contains Vent Burner Neck Valve Plate LED and Adjustable Air...

Страница 31: ...________________________________________________________ ________________________________________________________________________________ ______________________________________________________________...

Отзывы: