Heat & Glo 6000C-IFT Скачать руководство пользователя страница 22

22

Heat & Glo  •  6000C-IFT, 8000C-IFT Owner’s Manual  •  2502-981 Rev.  J

  

•  12/20  

Frequently Asked Questions and Troubleshooting 

A.  Frequently Asked Questions - Appliance

ISSUE

SOLUTIONS

 Condensation on the glass

This is a result of gas combustion and temperature variations. As the fireplace warms, this 

condensation will disappear.

 Blue flames

This is a result of normal operation and the flames will begin to yellow as the fireplace is al

-

lowed to burn for 20 to 40 minutes.

 Odor from fireplace

When first operated, this fireplace may release an odor for the first several hours. This is caused 

by the curing of the paint and the burning off of any oils remaining from manufacturing. Odor 

may also be released from finishing materials and adhesives used around the fireplace.  These 

circumstances may require additional curing related to the installation environment.

 Film on the glass

This is a normal result of the curing process of the paint and logs. Glass should be cleaned 

within 3 to 4 hours of initial burning to remove deposits left by oils from the manufacturing 

process. A non-abrasive cleaner such as gas fireplace glass cleaner may be necessary. See 

your dealer.

 Metallic noise

Noise is caused by metal expanding and contracting as it heats up and cools down, similar to 

the sound produced by a furnace or heating duct. This noise does not affect the operation or 

longevity of the fireplace.

Is it normal to see the pilot flame burn  

continually?

In an intermittent pilot ignition system (IPI), the pilot flame should turn off when appliance is 

turned off. Some optional control systems available with IPI models may allow pilot flame to 

remain lit.

Power Outages

(battery backup)

This appliance can be operated on battery power in the event of a power outage.  To access 

the battery pack, the decorative front, mesh and glass assembly must be removed.  Refer to 

Section 3 for more details.

Wall above appliance feels hot to   

 the touch.

No action necessary.  This appliance ships with a non-combustible material attached. Speci-

fications of the attached non-combustible material are listed in the Installer’s Manual for this 

appliance.

Contact your dealer

 for additional information regarding operation and troubleshooting.  Visit www.heatnglo.com to 

locate a dealer.

Содержание 6000C-IFT

Страница 1: ...r See appliance installation manual for additional Commonwealth of Massachusetts requirements DO NOT store or use gasoline or other flam mable vapors and liquids in the vicinity of this or any other a...

Страница 2: ...z Gaz N NA ATURAL TURAL GAS GAS MADE MADE IN IN USA USA Minimum Minimum Permissible Permissible Gas Gas Supply Supply for for Purposes Purposes of of Input Input Adjustment Adjustment Approved Approve...

Страница 3: ...s 16 B Maintenance Tasks Homeowner 16 C Maintenance Tasks Qualified Service Technician 18 5 Frequently Asked Questions and Troubleshooting A Frequently Asked Questions Appliance 22 B Frequently Asked...

Страница 4: ...ized HHT dealer or distributor whichever occurs earlier However the Warranty coverage shall commence no later than 24 months following the date of Product shipment from HHT regardless of the installat...

Страница 5: ...or handling devices such as exhaust fans or forced air furnaces or other such causes 6 use of fuels other than those specified in the operation instructions 7 installation or use of components not su...

Страница 6: ...ries Inc UL TYPE Direct Vent Heater STANDARD CSA ANSI Z21 88 19 CSA 2 33 19 B Tempered Glass Specifications Hearth Home Technologies appliances manufactured with tempered glass may be installed in haz...

Страница 7: ...the fireplace Consider not using the fireplace when children will be present Contact your dealer for more information or visit www hpba org Product Info Fireplace Stove Heater Glass Fronts Safety To...

Страница 8: ...allation site Conversions must be made by a qualified service technician using Hearth Home Technologies specified and approved parts Figure 3 3 Good Faith Wall Surface Temperatures Above Appliance D G...

Страница 9: ...el to model actual TV temperatures should be validated at the me of each installa on TVs should not be used in situa ons where the actual TV temperature exceeds the manufacturers maximum allowable ope...

Страница 10: ...been removed from inside and or underneath the firebox Review proper placement of logs ember material and or other decorative materials Check the wiring Check the air shutter adjustment Ensure that th...

Страница 11: ...11 Heat Glo 6000C IFT 8000C IFT Owner s Manual 2502 981 Rev J 12 20 F Lighting Instructions IPI...

Страница 12: ...control If this occurs restart the appliance NOTICE Open windows for air circulation during fire place break in Some people may be sensitive to smoke and odors Smoke detectors may activate H Heat Mana...

Страница 13: ...ory installed battery pack is located in the control cavity of the appliance See Figure 3 5 Battery longevity and performance will be affected by long term exposure to the service temperatures of this...

Страница 14: ...to pair the IFT ECM with the IFT ACM if installed and or IFT RC400 and IFT RC150 remote controls See the IFT RC400 or IFT RC150 installation manual for detailed instructions on pairing the IFT ECM wit...

Страница 15: ...s Kit draws heat from your fireplace to an adjacent room in your home up to 20 feet away Optional Heat Out Gas Kit The Heat Out Gas heat management option is available for use with the 6000C IFT and 8...

Страница 16: ...material etc It is imperative that control compartments burners and circulating air passageways of the appliance be kept clean Any safety screen guard or barrier removed for servicing the appli ance...

Страница 17: ...damage and repair as necessary Check that fireplace openings are not blocked Vacuum and dust surfaces Remote Control Frequency Seasonally By Homeowner Tools needed Replacement batteries and remote co...

Страница 18: ...ded Remove all foreign objects Verify unobstructed air circulation Burner Ignition and Operation Frequency Annually By Qualified Service Technician Tools needed Protective gloves vacuum cleaner whisk...

Страница 19: ...me Remove glass assembly from the appliance See Figure 4 1 Note It may be necessary to remove logs in order to clean and inspect the glass refractory Reinstall logs using instructions included in appl...

Страница 20: ...ry grate and valve assemblies This task should be performed by a qualified service technician The refractory grate and base refractory do not need to be removed to service the burner assembly Figure 4...

Страница 21: ...by a qualified ser vice technician The base refractory valve plate and grate do not need to be removed to access the burner assembly The logs and fiber burner top need to be removed to access the burn...

Страница 22: ...s left by oils from the manufacturing process A non abrasive cleaner such as gas fireplace glass cleaner may be necessary See your dealer Metallic noise Noise is caused by metal expanding and contract...

Страница 23: ...etween the desired room temperature and actual temperature In thermostat mode the hearth appliance will start in HI flame but as the actual temperature approaches the desired set temperature on the re...

Страница 24: ...r switch is in ON or REM position Verify AC power available to junction box Verify AC DC adaptor is plugged into junction box and ECM Verify AC DC adaptor output voltage is between 5 7 6 3 Vdc If batt...

Страница 25: ...valve solenoid resistance nominal is 60 ohms If open or shorted replace valve Verify valve inlet pressure is correct for gas type Pilot and main do not light ECM goes into 5 Red 1 Green Lockout Power...

Страница 26: ...our fireplace For safety Install a switch lock or a wall remote control with child protection lockout feature Keep remote controls out of reach of children See your dealer if you have questions Instal...

Страница 27: ...164 701 2 Log 2 SRV2164 702 3 Log 3 SRV2164 703 4 Log 4 SRV2164 704 5 Log 5 SRV2164 705 6 Log 6 SRV2164 706 7 Insulation Board 2166 136 8 Burner Top SRV2166 100 Y 9 Burner NG 2164 007 Y Burner Propane...

Страница 28: ...GS 8C Y 1 Log 1 SRV2168 701 2 Log 2 SRV2168 702 3 Log 3 SRV2168 703 4 Log 4 SRV2168 704 5 Log 5 SRV2168 705 6 Log 6 SRV2168 706 7 Insulation Board 2170 136 8 Burner Top SRV2170 100 Y 9 Burner NG 2168...

Страница 29: ...Bracket 2118 104 18 5 Flex Ball Valve Assembly SRV302 320 Y 18 6 Valve NG SRV2166 302 Y Valve Propane 2166 303 Y 18 7 Male Connector Pkg of 5 303 315 5 Y 18 8 Bulkhead W Tube SRV7000 156 Y 18 9 Jumper...

Страница 30: ...or Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER Exhaust Shield 385 105 Flue Restrictor Qty 2 req 385 328 Gasket Assembly 2166 081 Contains Vent Burner Neck Valve Plate LED and Adjustable Air...

Страница 31: ...________________________________________________________ ________________________________________________________________________________ ______________________________________________________________...