HearthStone hase lima 8150 Скачать руководство пользователя страница 21

Hearthstone 

Quality Home Heating Products, Inc 

®                                                                                                                                                                      Lima Model 8150            

21 

a high rate of burn; or push it in for a low rate of 
burn. The air control does not close completely. 

 

Note:

  When opening the front door to reload 

or re-arrange logs, it is advisable to open the 
door  just  a  crack,  pause  for  a  moment  then 
open  the  door  completely.  This  procedure 
allows  the  firebox  to  clear  of  smoke  before 
the  door  is  open  fully.  In  addition,  reloading 
on  a  bed  of  hot,  red  coals  reduces  smoking 
time  and  brings  fresh  fuel  up  to  a  high 
temperature rapidly. 

B

URN 

R

ATE 

 

HIGH  BURN:

  Fully  load  the  firebox  with  wood  on  a 

bed  of  hot  coals  or  on  an  actively  flaming  fire  and 
fully  open  the  primary  air  control  by  pulling  it  all  the 
way  out,  away  from  the  firebox.  A  high  burn  rate 
once  or  twice  a  day  to  heat  the  stovepipe  and 
chimney 

fully, 

will 

help 

minimize 

creosote 

accumulation.   

MEDIUM  HIGH  BURN:

  With  the  primary  air  control 

in the open position, push the control handle slightly 
towards the firebox, or about ¼ to ½ the way in. 

MEDIUM  LOW  BURN:

  With  the  primary  air  control 

in  the  open  position,  push  the  handle  inward  about 
¾  of  the  way  in.  A  medium-low  burn  rate  is  the 
typical  setting  and  is  preferable  if  the  stove  is 
unattended.  

LOW BURN: 

Push the primary air control inward all 

the  way to the firebox. This closes the air shutter to 
its minimum opening. A low burn rate over extended 
periods  is  not  advisable  as  it  can  promote  the 
accumulation  of  creosote.  Inspect  the  venting 
system  frequently 

if 

using 

low 

burn 

rates 

consistently.  

O

VER

-F

IRE 

C

AUTION 

 

Over-firing  means  the  stove  is  operating  at 
temperatures 

above 

the 

recommended 

temperatures  outlined  in  the 

BURN  RATE

  section. 

Carefully  avoid  over-firing,  as  it  will  damage  the 
stove.  Symptoms  of  chronic  over-firing  can  include 
warped  components,  short  burn  times,  a  roaring 
sound in the stove or stovepipe, and discoloration of 
the stovepipe. 

Excessive  draft,  inappropriate  fuel,  and  operator 
error  can  cause  over-firing.  Correct  an  over-fire 
situation as follows: 

 

EXCESSIVE  DRAFT:

  Contact  your  local  dealer 

to  have  a  draft  reading  taken.  Any  draft  in 
excess  of  0.1  WC  requires  a  damper  in  the 

stovepipe.  Some  installations  may  require  more 
than one damper. 

 

INAPPROPRIATE FUEL:

 Do not burn coal; kiln 

dried  lumber,  wax  logs  or  anything  other  than 
natural cordwood. 

 

OPERATOR  ERROR:

  Ensure  all  the  gaskets 

are  in  good  condition.  Replace  worn  out  or 
compressed gaskets. Do not burn the stove with 
the  front  door,  ash  pan,  or  the  ash  grate  in  the 
open position. 

If  you  suspect  that  your  stove  is  over-firing,  contact 
your dealer immediately.

 

Damage caused by over-

firing is not covered by your warranty

Results of 

over-firing can include warped or burned out internal 
parts,  cracked  vermiculite  panels,  discolored  or 
warped external parts, and damaged finish. 

R

EMOVAL 

A

ND 

D

ISPOSAL 

O

A

SHES 

 

Remove  ashes  only  when  the  stove  is  cold.  Use 
protective fireplace gloves if the ash pan is warm.  

The ash pan is located behind the control door. The 
ash  pan  collects  burned  ash  from  a  fire  and  allows 
you to remove the ash conveniently from your wood 
stove.  Clear  the  firebox  of  ashes  often,  and  do  not 
let  them  build  up  more  than  3  inches  high.  It  is 
important  to  prevent  ashes  from  building  up  around 
the  front  door  opening.  To  remove  ashes,  pull  the 
grate  lever  out  to  open  the  grate.  Sift  the  ashes 
across  the  grate  into  the  ash  pan.  Then  return  the 
ash grate to its closed  position  by pushing the lever 
back  in  towards  the  stove.  The  ash  pan  is  easy  to 
remove  and  has  a  handle  and  lid  for  convenient 
disposal of ashes. The lid  must be stored under the 
ash  pan  when  burning  the  stove.  The  ash  pan  will 
not seal properly without the lid under it. 

Dump  ashes  from  the  ash  pan  directly  into  a 

metal

 

container  with  a  tight  fitting  lid.  Do  not  place  any 
other items or trash into the metal container. Do not 
pour  water  into  the  container.  Replace  the 
container’s  lid  and  allow  the  ashes  to  cool.  Never 
place  the  ash  disposal  container  on  a  combustible 
surface  or  vinyl  flooring,  as  the  container  could  be 

hot! 

Pending disposal, place the closed ash container on 
a  noncombustible  floor  or  on  the  ground,  well  away 
from  all  combustible  materials,  liquid  fuels,  or 
vehicles.  Retain  ashes  in  the  closed  container  until 
all coals thoroughly cool. 

 

NEVER

  place  ashes  in  wooden  or  plastic  containers, 

in  trashcans  with  other  trash,  or  in  paper  or  plastic 
bags, no matter how long the fire has been out. Coals 
within a bed of ashes can remain hot for several days 
once removed from the firebox. 

Содержание hase lima 8150

Страница 1: ...HIS ENTIRE OWNER S MANUAL BEFORE YOU INSTALL AND USE YOUR NEW LIMA WOOD STOVE To reduce the risk of fire follow the installation instructions Failure to follow these instructions can result in propert...

Страница 2: ...Hearthstone Quality Home Heating Products Inc Lima Model 8150 2 Intentionally Blank...

Страница 3: ...OUTSIDE AIR SUPPLY 12 VENTING COMPONENTS AND CONFIGURATION REQUIREMENTS 12 INSTALLING A VENTING SYSTEM 13 CONNECTING THE STOVE TO A CHIMNEY 13 INSTALLING IN A MOBILE HOME 17 OPERATING YOUR LIMA WOOD S...

Страница 4: ...a away from traffic flow doors and hallways If possible try to install the stove near an existing chimney and chimney connector It is extremely important to install this stove with the proper clearanc...

Страница 5: ...y this stove in any way Never burn kiln dried painted or treated wood in this stove Never burn garbage or trash colored or glossy paper solvents plywood artificial logs cardboard or driftwood in this...

Страница 6: ...INSTANTANEOUS STEAM AND SERIOUS BODILY HARM Once the chimney fire expires leave the primary air control closed and let the fire in the stove die out completely Inspect the stove stovepipe and chimney...

Страница 7: ...ase You must carefully consider the clearances to all of these combustibles before actually connecting your stove If the floor is made of combustible material then a non combustible floor protector is...

Страница 8: ...own in previous figures are from the body of the stove The Lima wood stove has a unique feature that allows it to rotate This rotation allows positioning the body of the stove into 13 different positi...

Страница 9: ...ne Quality Home Heating Products Inc Lima Model 8150 9 Figure 4 Remove Mounting Screw Figure 5 Insert First Rotation Locking Stopper Figure 6 Insert Second Rotation Lock Stopper Figure 7 Tighten Mount...

Страница 10: ...n Position G H E A C D Stove Free to Rotate B F J Stove Locked in Position I K Figure 8 Clearance to combustibles Parallel Corner Clearances A B C D E F G H I J K Single or double wall Inches 38 17 26...

Страница 11: ...a ventilated thimble minimum 24 gauge in thickness having two 1in air channels separated from combustibles by a minimum of 6in of glass fiber insulation Opening shall be covered and thimble supported...

Страница 12: ...talbestos DS Security GSW and Ameritec also have acceptable close clearance connector pipe When used in a mobile home a spark arrester is required See page 16 The chimney connector cannot pass through...

Страница 13: ...n create a higher than normal draft In such cases a damper can help regulate the draft The Lima requires a draft between 0 06 and 0 1 WC For drafts above 0 1 WC install a stovepipe damper Check the dr...

Страница 14: ...versized flue contributes to the accumulation of creosote Use the following checklist to ensure that your masonry chimney meets these minimum requirements Masonry Chimney wall construction Mortared br...

Страница 15: ...Hearthstone Quality Home Heating Products Inc Lima Model 8150 15 Figure 10 Typical Venting Configurations...

Страница 16: ...Hearthstone Quality Home Heating Products Inc Lima Model 8150 16 Figure 11 Chimney Height Roof Clearance Requirements 3 0 MINIMUM 10 0 2 0 MINIMUM 3 0 MINIMUM 2 0 MINIMUM...

Страница 17: ...all one of the following Dura Vent Mobile Home Chimney Connector Kits 6DP MH 6 Diameter S N 9096N 7DP MH 7 Diameter S N 9196N 8DP MH 8 Diameter S N 9296N Each kit includes Stainless spark arrester cap...

Страница 18: ...pen the control door and locate the ash pan s handle To remove the ash pan grip the handle rotate it clockwise turn and then pull it out The lid for the ash pan is stored under the ash pan Use the lid...

Страница 19: ...d with higher a BTU content is generally considered ideal for a wood stove WOOD HEAT VALUE Common Name Lb cord MBTU cord High Osage Orange Hedge 4 728 32 9 Hickory Shagbark 4 327 27 7 Hop Hornbeam Iro...

Страница 20: ...alleviate these odors by opening a few windows or otherwise creating additional ventilation around your stove If any odor persists contact your dealer or an authorized service technician If you adhere...

Страница 21: ...lations may require more than one damper INAPPROPRIATE FUEL Do not burn coal kiln dried lumber wax logs or anything other than natural cordwood OPERATOR ERROR Ensure all the gaskets are in good condit...

Страница 22: ...ey at the top where it is coolest as well as from the bottom near the stove 6 Remove accumulated creosote with a cleaning brush specifically designed for the type of chimney in use Use a certified chi...

Страница 23: ...gasket was not fully inserted into the channel or where stretched thinner or adjacent to an area where the gasket was compressed thicker 6 First adjust the gasket as necessary by reseating it uniform...

Страница 24: ...glass immediately if broken or chipped Contact your local dealer for replacement glass The glass kit includes instructions and everything needed for the repair If you replace the glass yourself wear...

Страница 25: ...y placing each one into the right most position and then slide it to the left All side panels are identical 7 Replace the side panel lock plate 8 Push side panels together tightly and center them so t...

Страница 26: ...as follows An AIRTIGHT HOUSE The air supply infiltration to the interior of the house may be inadequate if your home is super insulated or especially well sealed This phenomenon of air starvation wit...

Страница 27: ...ing poor quality or green wood UNCONTROLLED OR SHORT BURN Unsealed or Open Door Open ash grate Close the door tightly or replace the gaskets Slide ash grate to closed position Excessive Draft Check th...

Страница 28: ...Y AIR PIPE 605 132 V ASH PAN FA ADE 360 080 V3 ASH TRAY 2 2110 701 ASH GRATE ROTATING 360 077 V ASH TRAY COVER 2110 700 ASH GRATE BASE 635 052 V3 ASH GRATE PLATE CAST 4700 200555 GRATE ROD 780 017 V U...

Страница 29: ...Hearthstone Quality Home Heating Products Inc Lima Model 8150 29 Safety Label...

Страница 30: ...Hearthstone Quality Home Heating Products Inc Lima Model 8150 30 Notes...

Страница 31: ...The Original Purchaser should complete their warranty registration on our website at http www hearthstonestoves com customer resources warranty registration NOTE FILLING OUT THE WARRANTY REGISTRATION...

Отзывы: