HearthStone hase lima 8150 Скачать руководство пользователя страница 12

Hearthstone 

Quality Home Heating Products, Inc 

®                                                                                                                                                                      Lima Model 8150            

12 

O

UTSIDE 

A

IR 

S

UPPLY

 

(Kit #91- 53700) 

You  can  connect  an  outside  air  source  directly  to 
this  stove  using  an  optional  outside  air  kit.  The 
advantage  of  providing  outside  air  directly  to  the 
stove is that the air used by the stove for combustion 
is taken from outside the residence rather than from 
within the room where the stove is located.   

The outside air kit for this stove allows for the direct 
connection of the stove's air intake to a minimum 3" 
(76  mm)  diameter  duct  (supplied  by  others)  which 
leads to the outside of the house. When considering 
placement of the duct from the outside of the house 
to  the  hearth,  keep  in  mind  the  need  to  avoid 
structural members of the house. The outside air kit 
will attach to the back of the stove. 

The  International  Residential  Code  (IRC)  does  not 
allow  the  outside  air  duct  to  terminate  higher  than 
the  appliance.  Some  building  officials  also  do  not 
like to see any vertical rise in the duct’s termination. 
Hearthstone  recommends  the  termination  be  at  the 
same level, or lower than the air intake on the stove. 

Locate  the  termination  of  the  duct  on  the  outside 
wall  of  the  home  in  such  a  manner  to  avoid  the 
possibility  of  obstruction  by  snow,  leaves  or  other 
material. Screen the termination using ¼” x ¼” mesh 
rodent  screen  and  cover  it  with  a  rain/wind  proof 
hood (flex pipe, outside termination, mesh, and hood 
supplied  by  others)*  Contact  your  dealer  for 
availability).  

*An adaptor for 4” duct is available from Hearthstone 
if needed. Kit # 90-53308. 

V

ENTING 

C

OMPONENTS AND 

C

ONFIGURATION REQUIREMENTS

 

 

WARNING:  DO  NOT  CONNECT  THIS  UNIT  TO  A 
CHIMNEY FLUE USED BY ANOTHER APPLIANCE 

 

Single wall connector that is 24 MSG or 25 MSG 
blued steel stovepipe. 

 

Double wall connector (close clearance pipe) 
which is used with a listed, factory-

built “Type HT" 

chimney or with a masonry chimney to reduce 
clearances, is available from several 
manufacturers, your dealer can help you choose. 
Some air insulated connector pipe models 
available are Simpson Dura Vent DVL and 
Metalbestos DS. Security, GSW and Ameritec 
also have acceptable close clearance connector 
pipe. 

 

When used in a mobile home, a spark arrester is 
required. (See page 16) 

 

The  chimney  connector  cannot  pass  through  a 
floor or ceiling, nor any attic or roof space, closet 
or  similar  concealed  space.  Where  venting 
requires  passage  through  a  wall  or  partition  of 
combustible  construction,  the  installation  must 
conform to NFPA Code 211 or CAN/CSA - B365. 

 

It is very important to follow minimum clearances 
for  chimney  connectors  to  combustibles  such  as 
walls  and  ceilings  when  installing  the  stove. 
Typical  chimney  connector  clearances  are 
outlined  below.  The  single  wall  clearances  are 
generic; the double wall clearances shown are for 
Simpson DuraVent DVL.  

 

CHECK  THE  SPECIFICATIONS  FROM  THE 
MANUFACTURER OF YOUR CONNECTOR.

 

C

OMPONENTS OF A 

V

ENTING 

S

YSTEM

 

The  complete  venting  system  consists  of  several 
components:    chimney  connector,  wall  thimble,  wall 
pass-through,  chimney,  and  liner.  It  is 

absolutely 

necessary

  that  you  install  all  of  these  components 

and  maintain  the  clearances  to  combustibles 
discussed earlier to ensure a safe stove installation. 

To protect against the possibility of a house fire, you 

must  properly  install  and  constantly  maintain  the 
venting  system

.  Upon  inspection,  immediately 

replace rusted, cracked, or broken components.   

 

The 

chimney connector

 is the stovepipe from the 

woodstove  to  the  chimney.  The  chimney 
connector stovepipe is 6" (152 mm) diameter, 24 
MSG or 25 MSG blued steel connector pipe. 

Do 

not use aluminum or galvanized steel pipe

 - they 

cannot withstand the extreme temperatures of a 
wood fire. 

 

The 

thimble

  is  a  manufactured  (or  site-

constructed)  device  installed  in  combustible 
walls  through  which  the  chimney  connector 
passes  to  the  chimney.  It  keeps  the  walls  from 
igniting.  You  must  use  a  wall  thimble  when 
installing  a  chimney  connector  through  a 
combustible wall to the chimney.   

 

wall  pass-through

  (or  chimney  support 

package) also keeps the walls from igniting. You 
must use one when connecting through a wall or 
ceiling to a prefabricated chimney.   

 

Only  install  this  stove  to  a 

lined  masonry 

chimney

  or  an  approved  high  temperature 

prefabricated  residential

  type  building  heating 

appliance chimney. 

Do not

 connect this stove to 

Содержание hase lima 8150

Страница 1: ...HIS ENTIRE OWNER S MANUAL BEFORE YOU INSTALL AND USE YOUR NEW LIMA WOOD STOVE To reduce the risk of fire follow the installation instructions Failure to follow these instructions can result in propert...

Страница 2: ...Hearthstone Quality Home Heating Products Inc Lima Model 8150 2 Intentionally Blank...

Страница 3: ...OUTSIDE AIR SUPPLY 12 VENTING COMPONENTS AND CONFIGURATION REQUIREMENTS 12 INSTALLING A VENTING SYSTEM 13 CONNECTING THE STOVE TO A CHIMNEY 13 INSTALLING IN A MOBILE HOME 17 OPERATING YOUR LIMA WOOD S...

Страница 4: ...a away from traffic flow doors and hallways If possible try to install the stove near an existing chimney and chimney connector It is extremely important to install this stove with the proper clearanc...

Страница 5: ...y this stove in any way Never burn kiln dried painted or treated wood in this stove Never burn garbage or trash colored or glossy paper solvents plywood artificial logs cardboard or driftwood in this...

Страница 6: ...INSTANTANEOUS STEAM AND SERIOUS BODILY HARM Once the chimney fire expires leave the primary air control closed and let the fire in the stove die out completely Inspect the stove stovepipe and chimney...

Страница 7: ...ase You must carefully consider the clearances to all of these combustibles before actually connecting your stove If the floor is made of combustible material then a non combustible floor protector is...

Страница 8: ...own in previous figures are from the body of the stove The Lima wood stove has a unique feature that allows it to rotate This rotation allows positioning the body of the stove into 13 different positi...

Страница 9: ...ne Quality Home Heating Products Inc Lima Model 8150 9 Figure 4 Remove Mounting Screw Figure 5 Insert First Rotation Locking Stopper Figure 6 Insert Second Rotation Lock Stopper Figure 7 Tighten Mount...

Страница 10: ...n Position G H E A C D Stove Free to Rotate B F J Stove Locked in Position I K Figure 8 Clearance to combustibles Parallel Corner Clearances A B C D E F G H I J K Single or double wall Inches 38 17 26...

Страница 11: ...a ventilated thimble minimum 24 gauge in thickness having two 1in air channels separated from combustibles by a minimum of 6in of glass fiber insulation Opening shall be covered and thimble supported...

Страница 12: ...talbestos DS Security GSW and Ameritec also have acceptable close clearance connector pipe When used in a mobile home a spark arrester is required See page 16 The chimney connector cannot pass through...

Страница 13: ...n create a higher than normal draft In such cases a damper can help regulate the draft The Lima requires a draft between 0 06 and 0 1 WC For drafts above 0 1 WC install a stovepipe damper Check the dr...

Страница 14: ...versized flue contributes to the accumulation of creosote Use the following checklist to ensure that your masonry chimney meets these minimum requirements Masonry Chimney wall construction Mortared br...

Страница 15: ...Hearthstone Quality Home Heating Products Inc Lima Model 8150 15 Figure 10 Typical Venting Configurations...

Страница 16: ...Hearthstone Quality Home Heating Products Inc Lima Model 8150 16 Figure 11 Chimney Height Roof Clearance Requirements 3 0 MINIMUM 10 0 2 0 MINIMUM 3 0 MINIMUM 2 0 MINIMUM...

Страница 17: ...all one of the following Dura Vent Mobile Home Chimney Connector Kits 6DP MH 6 Diameter S N 9096N 7DP MH 7 Diameter S N 9196N 8DP MH 8 Diameter S N 9296N Each kit includes Stainless spark arrester cap...

Страница 18: ...pen the control door and locate the ash pan s handle To remove the ash pan grip the handle rotate it clockwise turn and then pull it out The lid for the ash pan is stored under the ash pan Use the lid...

Страница 19: ...d with higher a BTU content is generally considered ideal for a wood stove WOOD HEAT VALUE Common Name Lb cord MBTU cord High Osage Orange Hedge 4 728 32 9 Hickory Shagbark 4 327 27 7 Hop Hornbeam Iro...

Страница 20: ...alleviate these odors by opening a few windows or otherwise creating additional ventilation around your stove If any odor persists contact your dealer or an authorized service technician If you adhere...

Страница 21: ...lations may require more than one damper INAPPROPRIATE FUEL Do not burn coal kiln dried lumber wax logs or anything other than natural cordwood OPERATOR ERROR Ensure all the gaskets are in good condit...

Страница 22: ...ey at the top where it is coolest as well as from the bottom near the stove 6 Remove accumulated creosote with a cleaning brush specifically designed for the type of chimney in use Use a certified chi...

Страница 23: ...gasket was not fully inserted into the channel or where stretched thinner or adjacent to an area where the gasket was compressed thicker 6 First adjust the gasket as necessary by reseating it uniform...

Страница 24: ...glass immediately if broken or chipped Contact your local dealer for replacement glass The glass kit includes instructions and everything needed for the repair If you replace the glass yourself wear...

Страница 25: ...y placing each one into the right most position and then slide it to the left All side panels are identical 7 Replace the side panel lock plate 8 Push side panels together tightly and center them so t...

Страница 26: ...as follows An AIRTIGHT HOUSE The air supply infiltration to the interior of the house may be inadequate if your home is super insulated or especially well sealed This phenomenon of air starvation wit...

Страница 27: ...ing poor quality or green wood UNCONTROLLED OR SHORT BURN Unsealed or Open Door Open ash grate Close the door tightly or replace the gaskets Slide ash grate to closed position Excessive Draft Check th...

Страница 28: ...Y AIR PIPE 605 132 V ASH PAN FA ADE 360 080 V3 ASH TRAY 2 2110 701 ASH GRATE ROTATING 360 077 V ASH TRAY COVER 2110 700 ASH GRATE BASE 635 052 V3 ASH GRATE PLATE CAST 4700 200555 GRATE ROD 780 017 V U...

Страница 29: ...Hearthstone Quality Home Heating Products Inc Lima Model 8150 29 Safety Label...

Страница 30: ...Hearthstone Quality Home Heating Products Inc Lima Model 8150 30 Notes...

Страница 31: ...The Original Purchaser should complete their warranty registration on our website at http www hearthstonestoves com customer resources warranty registration NOTE FILLING OUT THE WARRANTY REGISTRATION...

Отзывы: