Hearthstone Quality Home Heating Products, Inc
® Castleton Model 8030 AU
8
C
OMBUSTIBLE
S
URFACE
R
EQUIRED
C
LEARANCES
Note: Dimensions shown in the following figures are from the top casting unless otherwise indicated.
Clearances to combustible walls may be reduced as shown below with 1140 mm wide by 1800 mm high
Skamotec panels applied directly to the side and rear walls.
It is very important to follow minimum clearances for chimney connectors to combustibles such as walls and
ceilings when installing the stove near combustible surfaces.
O
UTSIDE
A
IR
S
UPPLY
(Optional Kit #90-53300)
You can connect an outside air source directly to
this stove using an optional outside air kit. The
advantage of providing outside air directly to the
stove is that the air used by the stove for combustion
is taken from outside the residence rather than from
within the room where the stove is located.
The outside air kit for this stove allows for the direct
connection of the stove's air intake to a minimum 3"
(76 mm) diameter duct (supplied by others)* which
leads to the outside of the house. When considering
placement of the duct from the outside of the house
to the hearth, keep in mind the need to avoid
structural members of the house. The outside air kit
attaches to the underside of the stove. Refer to the
instructions provided with the kit for installation.
*An adaptor for 4” duct is available if needed. KIT
#90-53308
Figure 3 – Clearance to Combustibles