HearthStone Quality Home Heating Products, Inc ®
8
WFP-75 Model 8411
2
GENERAL INFORMATION
APPLIANCE PERFORMANCE
(1)
Fuel type
Dry cordwood
Recommended heating area
[*]
750 to 2,200 ft
2
(46 to 186 m
2
)
Firebox volume
2.5 ft
3
(0.071 m
3
)
Maximum burn time
[*]
9 h
Maximum heat output
(2)
(dry cordwood)
80,000 BTU/h
Overall heat output rate (min. to max.)
(2)(3)
14,200 BTU/h to 48,200 BTU/h (4.16 kW to 14.13 kW)
Average overall efficiency
(3)
- Dry cordwood
68% (HHV
(4)
)
73% (LHV
(5)
)
Optimum efficiency
(2)(6)
74%
Average particulate emissions rate
(7)
1.14 g/h (
EPA / CSA B415.1-10
)
(8)
Average CO
(9)
53 g/h
[*]
Recommended heating area and maximum burn time may vary subject to location in home, chimney draft, heat loss factors,
climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its
capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.
(1)
Values are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and
maximum heat output.
(2)
The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft
3
and 20 lb/ft
3
. Other
performances are based on a fuel load prescribed by the standard. The specified loading density varies between 7 lb/ft
3
and
12 lb/ft
3
. The moisture content is between 19% and 25%.
(3)
As measured per CSA B415.1-10 stack loss method.
(4)
Higher Heating Value of the fuel.
(5)
Lower Heating Value of the fuel.
(6)
Optimum overall efficiency at a specific burn rate (LHV).
(7)
This appliance is officially tested and certified by an independent agency.
(8)
Tested and certified in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and ASTM E3053-17.
(9)
Carbon monoxide.
GENERAL FEATURES
Maximum log length
(13)
20 in (508 mm) east-west
(10)
Flue outlet diameter
6
in (150
mm)
Chimney diameter
6
in (150
mm)
Type of chimney
CAN/ULC S629, UL 103 HT (2100 °F)
Baffle material
C-Cast
Approved for alcove installation
Not approved
Approved for mobile home installation
(11)
Not approved
Weight
(Including refractory panels, faceplate, and packaging)
575lb (261kg)
Type of door
Single, glass with cast iron frame
Type of glass
Ceramic glass
Blower
Included (up to 176 CFM)
Particulate emission standard
EPA / CSA B415.1-10
(12)
USA standard (safety)
UL 127
Canadian standard (safety)
ULC-S610
(10)
East-west: through the door you see the longitudinal sides of the logs; north-south: through the door you see the tips of the
logs.
(11)
Mobile home (Canada) or manufactured home (USA): The US department of Housing and Urban Development describes
“manufactured homes” better known as “mobile homes” as followed; buildings built on fixed wheels and those transported on
temporary wheels/axles and set on a permanent foundation. In Canada, a mobile home is a dwelling for which the
manufacture and assembly of each component is completed or substantially completed prior to being moved to a site for
installation on a foundation and connection to service facilities and which conforms to the CAN/CSA-Z240 MH standard.
(12)
Tested and certified in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and ASTM E3053-17.
(13)
The recommended log length is 16 inches, placed in the north-south orientation. For more details see section 3 - Fuel.
Содержание 8411
Страница 9: ...HearthStone Quality Home Heating Products Inc 9 WFP 75 Model 8411 2 3 DIMENSIONS General Dimensions ...
Страница 10: ...HearthStone Quality Home Heating Products Inc 10 WFP 75 Model 8411 Internal Dimensions Faceplate Projection ...
Страница 70: ...HearthStone Quality Home Heating Products Inc 70 WFP 75 Model 8411 SAFETY RATING LABEL ...
Страница 72: ...HearthStone Quality Home Heating Products Inc 72 WFP 75 Model 8411 ...