HearthStone Quality Home Heating Products, Inc ®
66
WFP-75 Model 8411
APPENDIX 9: SECONDARY AIR TUBES AND BAFFLE INSTALLATION
The secondary air tubes and the baffle must be in good working order to ensure clean combustions.
Remove any of the 4 secondary air tubes or the baffle to repalce damaged parts. See Appendix 11
for part numbers.
1. Starting with the rear tube, lean and insert the right end of the secondary air tube into the rear
right channel hole. Then lift and insert the left end of the tube into the rear left channel.
2. Align the notch in the left end of the tube with the key of the left air channel hole. Using pliers
hold the tube and lock it in place by turning the tube as shown. Make sure the notch reaches
the end of the key way.
3. Repeat for center back tube.
4. Put the baffle in place.
5. Repeat steps 1 and 2 for the two front tubes.
6. To remove the tubes use the above steps in
reverse order
Note that secondary air tubes (A) can be replaced
without removing the baffle board (B).