background image

Hearthstone 

Quality Home Heating Products, Inc. 

®                                                                                                                                                                     Heritage Model 8021 

Page 5 of 30 

Safety Information 

Read  and  understand  this  Owner's  Manual 
thoroughly  before  installing  and  using  this 
stove. 

C

ODES

 

When  you  install  your  Heritage  wood  stove,  it  is 
imperative  that  you  adhere  to all  local  codes,  which 
can  be  obtained  from  either  of  the  following  two 
National sources: 

American National Standards Institute, Inc. 

(ANSI) 

1430 Broadway 
New York, NY 10018 
www.ansi.org 

National Fire Protection Association, Inc. (NFPA) 

Battery March Park 
Quincy, MA 02269 
www.nfpa.org 

If you are installing your Heritage in a mobile home, 
follow  the  guidelines  described  in  the  Manufactured 
Home  Construction  and  Safety  Standard,  Title  24 
CFR, Part 3280 (United States). 

Make sure to install your stove: 

 

According 

to 

the 

manufacturer's 

recommendations. 

 

In accordance with all applicable codes. 

 

With the proper sized chimney. 

When using your stove: 

 

Warn  children  and  others  unfamiliar  with 
woodstoves  of  the  danger  of  touching  hot, 
radiating  surfaces  of  your  stove.    For  your 
additional safety, obtain hearth and stove guards 
through your local dealer. 

 

Follow  recommended  break-in  procedure  as 
outlined in this manual. 

 

Burn natural wood only.  Higher efficiencies and 
lower  emissions  result  when  burning  air-dried, 
seasoned  wood,  as  compared  to  green  or 
freshly cut wood. 

 

Use  caution  when  loading  firewood  into  a  hot 
stove. 

 

Keep the side and front doors closed at all times 
except when loading wood.

 

 

Keep the ash pan tray fully inserted and the ash 
door closed tightly.

 

 

Inspect  the  stovepipe,  chimney  connector  and 
chimney, as recommended. 

Follow these safety precautions: 

 

Never

  modify  this  stove  in  any  way,  especially 

the primary air control system. 

 

Never

  burn  kiln  dried  wood,  painted  or  treated 

wood,  solvents,  trash,  plywood,  colored  or 
glossy  paper,  artificial  logs,  cardboard,  coal, 
garbage  or  driftwood.   

Especially,  do  not  burn 

coal in this stove. 

 

Never

  use  gasoline  type  fuel,  kerosene, 

charcoal lighter fluid, or other liquid fuels or solid 
fire starters to start or invigorate the fire.  These 
fuels  can  possibly  generate  carbon  monoxide, 
which  can  deplete  the  supply  of  oxygen.    Keep 
all such materials away from the stove. 

 

Never

 use the stove if the ash pan door is open, 

damaged, not in place, or not sealing. 

 

Never

  use  a  wood  grate  or  other  device  to 

elevate the fire. 

 

Do  Not 

allow  wood  to  rest  against  or  otherwise 

come in contact with the glass when the door is 
closed. 

 

Do  Not

  slam  the  door  or  use  the  door  to  force 

wood in to the stove. 

 

Never

 over-fire your stove.  (See page 22) 

 

Never 

put articles of clothing or candles on a hot 

stove. 

 

Do Not

 connect the stove to a flue that is serves 

another appliance.  

Other safety guidelines 

 

As a general rule, keep all movable combustible 
items  such  as  furniture,  drapes,  clothing,  and 
other items, at least 36" (0.92 m) from the stove. 

 

Install  a  good  smoke  detector,  preferably  in  an 
area away from your wood stove. 

 

Keep a fire extinguisher handy.  We recommend 
the type rated "A B C." 

 

Dispose of ashes properly. (See page 22) 

 

Keep  children  and  pets  away  from  the  stove; 
they could be burned by touching a hot stove. 

 

Clean  your  chimney  system  as  needed.  (See 
page 23) 

Содержание 802

Страница 1: ...L AND USE YOUR NEW HERITAGE WOOD STOVE To reduce the risk of fire follow the installation instructions Failure to follow these instructions may result in property damage bodily injury or even death SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE CONTACT LOCAL AUTHORITIES HAVING JURISDICTION BUILDING DEPARTMENT or FIRE OFFICIALS ABOUT PERMITS REQUIRED RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR A...

Страница 2: ...Hearthstone Quality Home Heating Products Inc Heritage Model 8021 Page 2 of 30 Intentionally Blank ...

Страница 3: ...UPPLY 9 CLEARANCES TO COMBUSTIBLES 10 VENTING COMPONENTS AND CONFIGURATION 12 COMPONENTS OF A VENTING SYSTEM 12 INSTALLING A VENTING SYSTEM 12 CONNECTING YOUR WOOD STOVE 13 INSTALLING IN A MOBILE HOME 17 OPERATION 18 CONTROLS AND FEATURES 18 CHOOSING FIREWOOD 19 WOOD HEAT VALUE 19 BUILDING A FIRE 20 NORMAL OPERATION 21 REMOVAL AND DISPOSAL OF ASHES 22 MAINTENANCE 23 MONITORING STOVE TEMPERATURES 2...

Страница 4: ...re to follow these instructions can result in property damage bodily injury and even death Locate your stove in a safe convenient open area away from traffic flow doors and hallways and near a chimney and chimney connector Review the proper clearance measurements from combustible surfaces You can safely reduce required clearances in most cases by using the optional rear heat shield and also with a...

Страница 5: ... pan tray fully inserted and the ash door closed tightly Inspect the stovepipe chimney connector and chimney as recommended Follow these safety precautions Never modify this stove in any way especially the primary air control system Never burn kiln dried wood painted or treated wood solvents trash plywood colored or glossy paper artificial logs cardboard coal garbage or driftwood Especially do not...

Страница 6: ...tion area and maintain the low emission high efficiency combustion you desire This new technology will not corrode rust dissolve or lose its strength however it is vulnerable to puncture or cracking due to rough handling PLEASE EXERCISE CARE WHEN LOADING WOOD OR CLEANING YOUR STOVE NOT TO DAMAGE THE THERMO CERAMIC BAFFLE Located directly above the burner tubes in the firebox this white or grey she...

Страница 7: ...s Height 28 5 8 73 cm Width 29 3 8 75 cm Depth 21 3 4 55 cm Front Door Size 18 wide x 11 high 46 x 28 cm Side Door Size 9 5 wide x 10 high 24 x 25 4 cm Stovepipe Size 6 152 mm diameter Metal Chimney 6 152 mm inside diameter Masonry Chimney 6 15 2cm inside diameter round flue 8 x 8 20 x 20cm square flue Flue Exit Top or Rear Actual Weight 475 216 kg pounds Crate Dimensions H 38 97cm W 32 81 cm L 32...

Страница 8: ...d Check the listing of your pipe for actual clearances The diagrams in this manual represent typical installations but are specific to the Simpson Dura Vent DVL brand Clearances cannot be reduced without the use of close clearance connector pipe and or by protecting the surfaces per NFPA 211 standards Locate the stove centrally in your living area to allow the heat to travel naturally to distant r...

Страница 9: ...ately the 2 o clock position Figure 5 Wooden Handle Detail OUTSIDE AIR SUPPLY Kit 90 53210 An outside air source may be connected directly to this stove using an optional outside air kit The advantage of providing outside air directly to the stove is that the air used by the stove for combustion is taken from outside of the residence rather than from within the room where the stove is located With...

Страница 10: ...wall stove pipe with heat shield 15 7 9 12 29 4 0 11 21 24 5 63 5 Alcove Clearances inches Unprotected Surfaces Protected Surfaces NFPA 211 Minimum alcove width 61 49 Maximum alcove depth 48 48 Alcove ceiling above stove top 57 24 If you use a rear heat shield to obtain reduced clearances you must use the optional rear heat shield manufactured by Hearthstone available through your local dealer Clo...

Страница 11: ...Hearthstone Quality Home Heating Products Inc Heritage Model 8021 Page 11 of 30 Figure 9 Mantle Clearances Side View Figure 8 Mantle Clearances Front View ...

Страница 12: ...y necessary that you install all of these components within the clearances to combustibles discussed earlier to install your stove safely To protect against the possibility of a house fire you must properly install and constantly maintain the venting system Upon inspection immediately replace rusted cracked or broken components The chimney connector is the stovepipe from the woodstove to the chimn...

Страница 13: ...ze of the chimney s flue is appropriate for the Heritage The Heritage requires a 6 152 mm inside diameter flue for new installations A 6 diameter flue provides adequate draft and performance You can use an 8 203 mm diameter existing flue with a reducer An oversized flue contributes to creosote accumulation In this case bigger is NOT better When purchasing a prefabricated chimney to install with yo...

Страница 14: ...actory mortar At least 1 25 mm air space An equivalent flue liner must be a listed chimney liner system meeting type HT requirements or other approved material Interior chimney requirements At least 2 51 mm clearance to combustible structure Fire stops must be installed at the spaces where the chimney passes through floors and or ceiling Insulation must be 2 51 mm from the chimney Exterior chimney...

Страница 15: ...ted thimble minimum 24 gauge in thickness having two 1in air channels separated from combustibles by a minimum of 6in of glass fiber insulation Opening shall be covered and thimble supported with a sheet steel support minimum 24 gauge in thickness D Solid insulated listed factory built chimney length with an inside diameter 2in larger than the chimney connector and having 1in or more of insulation...

Страница 16: ...Hearthstone Quality Home Heating Products Inc Heritage Model 8021 Page 16 of 30 Figure 11 Typical Venting Configurations ...

Страница 17: ...e following Dura Vent Mobile Home Chimney Connector Kits 6DP MH 6 Diameter S N 9096N 7DP MH 7 Diameter S N 9196N 8DP MH 8 Diameter S N 9296N Each kit includes Stainless spark arrester cap storm collar Adjustable vented flashing 0 12 6 12 Two 24 Dura Plus chimney pipes 24 support box with built in starter section and trim UL or ULC approved equipment is acceptable EXTERIOR CHIMNEY SECTIONS MUST BE ...

Страница 18: ...ash lip The primary air control allows you to regulate the amount of air entering the firebox Generally the more air allowed into the firebox the faster and hotter the rate of burn conversely less air creates a slower burn To fully open the primary air intake move the handle as far as it will go to the left move the handle as far as it will go to the right to close the primary air control ASH PAN ...

Страница 19: ...ney 3 832 26 7 Apple 4 100 26 5 Mulberry 3 712 25 8 Oak White 4 012 25 7 Medium High Beech European 3 757 24 Maple Sugar 3 757 24 Oak Red 3 757 24 Ash White 3 689 23 6 Birch Yellow 3 689 23 6 Medium Juniper Rocky Mtn 3 150 21 8 Elm Red 3 112 21 6 Coffeetree Kentucky 3 112 21 6 Hackberry 3 247 20 8 Tamarack 3 247 20 8 Birch Gray 3 179 20 3 Birch White Paper 3 179 20 3 Walnut Black 3 192 20 2 Cherry...

Страница 20: ...pet and new textiles These odors will dissipate over time You can alleviate these odors by opening a few windows or otherwise creating additional ventilation around your stove If any odor persists contact your dealer or an authorized service technician If you adhere to the following break in procedure as well as all other operating procedures in this manual the cast iron and soapstone components o...

Страница 21: ... add logs small at first to build the fire up Make sure to keep the logs away from the glass in front in order for the air wash system to work properly Keep the front door and ash door closed while the stove is in use 6 Once the fire is burning well use the primary air control to regulate the desired rate of burn Pushing the handle to the left opens the PRIMARY AIR CONTROL for a high rate of burn ...

Страница 22: ...es when the stove is cold Use protective fireplace gloves if the ash pan is warm Exercise extreme caution when handling storing or disposing of ashes The ash pan and ash pan access door are located under the ash lip The ash pan collects ash from a firebox and allows you to conveniently remove the ash from your wood stove Clear the firebox of ashes often and do not allow them to build up more than ...

Страница 23: ...p Cooler surfaces tend to build creosote deposits quicker so it is important to check the chimney at the top where it is coolest as well as from the bottom near the stove Accumulated creosote should be removed with a cleaning brush specifically designed for the type of chimney in use A certified chimney sweep should be used to perform this service Contact your dealer for the name of a certified ch...

Страница 24: ...s in the clip 7 Screw the glass retainer clips 8 back on the door 8 Install the door Glass Cleaning When necessary clean the glass with low alkaline content commercial stove glass cleaners which are available from your local dealer Never attempt to clean the glass while the fire is burning or the glass is hot Most deposits can be cleaned by following the instructions provided with the cleaner To c...

Страница 25: ...n stone contact your dealer for service CAST IRON Exterior cast iron parts are either painted with black high temperature stove paint or porcelainized with an enamel finish in various colors Use black high temperature stove paint satin black by Stovebright to touch up and maintain the original appearance of painted cast iron Use a damp sponge to wipe clean Dry the cast iron thoroughly to prevent r...

Страница 26: ...ote a stronger draft Other draft guidelines are as follows AN AIRTIGHT HOUSE If your home is super insulated or especially well sealed the infiltration air supply to the interior of the house may be inadequate This phenomenon of air starvation within the building can be exacerbated if exhaust fans such as clothes dryers bathroom fans or cookstove exhaust fans are in operation within the home Outfi...

Страница 27: ...pty ash pan more frequently UNCONTROLLED OR SHORT BURN Unsealed or Open Door Open ash grate Close the door tightly or replace the gaskets Slide ash grate to closed position Excessive Draft Check the installation Operate at LOW BURN Install stovepipe damper Deteriorated Cement Seals Reseal the stove with furnace cement Extra Long Chimney Shorten the chimney Install stovepipe damper Oversized Chimne...

Страница 28: ... HER 5021 037 HANDLE ASH GRATE CONTROL 2010 910 FOOT HER HEP MISC 2010 245 PRIMARY MANIFOLD HER 6400 40444 OWNER S MANUAL 2010 242 SECONDARY MANIFOLD TOP HER 90 58210 COMPLETE GASKET KIT 2010 240 SECONDARY MANIFOLD BOTTOM HER 90 58215 FRONT DOOR GLASS KIT 2010 275 SIDE TRIM HER 90 71100 WOODEN HANDLE ASSEMBLY 2010 220 DOOR ASH PAN HER 90 73212 FRONT DOOR LATCH ASSEMBLY 2010 215 ASH PAN FRAME HER 1...

Страница 29: ...Hearthstone Quality Home Heating Products Inc Heritage Model 8021 Page 29 of 30 Safety Rating Label ...

Страница 30: ...r warranty registration on our website at www hearthstonestoves com customer resources warranty registration Hearthstone Quality Home Heating Products Inc Warranty Department 317 Stafford Avenue Morrisville VT 05661 NOTE COMPLETING THE WARRANTY REGISTRATION FORM IS NOT REQUIRED AS A CONDITION OF WARRANTY COVERAGE OR HEARTHSTONE S PERFORMANCE ...