background image

6

VENTILATION  AIR

Ventilation  Air  From  Outdoors

Provide    extra    fresh    air    by    using
ventilation    grills    or    ducts:  You    must
provide  two  permanent  openings: one
within  12

"

  of  the  ceiling  and  one  within

12

"

  of  the  floor.

Connect    these    items    directly    to    the
outdoors  or  spaces open to the  outdoors.
These  spaces  include  attics  and  crawl
spaces. Follow   the

   National  Fuel  Gas

Code  NFPA 54/ANS Z223.1, Section 5.3.
Air  for  Combustion  and  Ventilation  for
required  size of ventilation grills or ducts.

IMPORTANT:

  Do  not  provide  openings

for  inlet  or  outlet  air  into  attic  if  attic has
a    thermostat-controlled    power    vent.
Heated  air  entering  the  attic  will  activate
the  power  vent.

              NOTICE:

This  heater  is

intended   for  use  as  supplemental
heat. Use   this  heater  along  with
your  primary  heating  system. Do
not  install  this  heater  as your
primary  heat  source. If  you have
a    central    heating    system,  you
may    run    system’s    circulating
blower  while  using  heater. This
will      help    circulate  the    heat
throughout   the  house.  In  the
event  of  a  power outage,  you can
use  this  heater  as  your primary
heat  source.

                WARNING:     

A    qualified

service      person      must    install
heater.  Follow  all  local  codes.

CHECK  GAS TYPE

Use  only  Propane/LP gas. If  your
gas  supply is not  Propane/LP, do not
install heater. Call  dealer  where you
bought   heater  for  proper  type heater.

INSTALLATION  NEEDS

Before  installing  heater,  make  sure
you have  the  items  listed below.

piping (check  local  codes)

sealant (resistant  to  Propane/LP  gas)

equipment   shutoff   valve*

ground  joint  union

test  gauge   connection*

sediment   trap

tee   joint

pipe   wrench

*A   CSA/AGA  design-certified       equip-
ment   shutoff   valve  with  1/8

"

 NPT

tap   is   an   acceptable  alternative   to
test  gauge    connection.  Purchase
the   CSA/AGA    design    certified
equipment   shutoff   valve   from  your

dealer.

LOCATING  HEATER

This    heater    is    designed    to    be
mounted  on  a  wall.  You  can  locate
heater  on  floor,  away  from  a  wall.
An  optional  floor  mounting  stand is
needed.    Purchase      the      floor
mounting   stand   from   your   dealer.
See   Accessories,   page 17.
For    convenience    and    efficiency,
install  heater

where  there  is  easy  access for

            operation,  inspection,  and  service

 in coldest part of room

An  optional  fan  kit  is  available  from
your     dealer.      See     Accessories,
page 17.  If  planning  to  use  fan,
locate    heater    near    an    electrical
outlet.

INSTALLATION

CAUTION:

If    you    install    the

heater  in  a  home  garage

heater  pilot  and  burner  must

      be  at  least  18  inches  above
        floor.

locate   heater  where  moving

        vehicle  will  not  hit  it.

           CAUTION:  

 This  heater

creates    warm    air    currents.
These    currents    move    heat
t o   w a l l       s u r f a c e s     n e x t     t o
h e a t e r .   I n s t a l l i n g     h e a t e r
next    to    vinyl    or    cloth    wall
c o v e r i n g s     o r     o p e r a t i n g
heater   where  impurities  (such as
tobacco  smoke,  aromatic   candles,
cleaning    fluids,  oil  or  kerosene
lamps,  etc.)  in  the  air  exist  may
discolor   walls.

WARNING:

  Never  install

the  heater

 in a bedroom or bathroom.

 in a recreational vehicle.

where    curtains,    furniture,

      clothing,   or   other   flammable
      objects are less than  36 inches
      from  the  front,  top, or sides  of
      the  heater.

 as  a  fireplace  insert.

 in   high  traffic  areas.

 in   windy  or  drafty  areas.

Figure  3 -Ventilation  Air  from  Outdoors

Содержание HB20ML-1

Страница 1: ...ust be performed by a qualified installer service agency or gas supplier HB20TL 1 HB30TL 1 HB20ML 1 HB30ML 1 Table of Contents ImportantSafetyInformation 2 Product Features 3 ProperVentilation FreshAi...

Страница 2: ...e of heater becomes very hot when running heater Keep children and adults away from hot surface to avoid burns or clothing ignition Heater will remain hot for a time after shuting down Allow surface t...

Страница 3: ...tion Inc Batterymarch Park Quincy MA 02269 QUALIFIED INSTALLING AGENCY Installation and replacement of gas piping gas utiliza tion equipment or accessories and repair and servicing of equipment shall...

Страница 4: ...of the methods described in the National Fuel Gas Code ANS Z223 1 Section 5 3 or applicable local codes Unusually Tight Construction The air that leaks around doors and windows may provide enough fre...

Страница 5: ...uel burning appliances in the space Vent free heater Btu Hr Gas water heater Btu Hr Gas furnace Btu Hr Vented gas heater Btu Hr Gas Fireplace logs Btu Hr Other gas appliances Btu Hr Total Btu Hr Do no...

Страница 6: ...pment shutoff valve ground joint union test gauge connection sediment trap tee joint pipe wrench A CSA AGA design certified equip ment shutoff valve with 1 8 NPT tap is an acceptable alternative to te...

Страница 7: ...s near bottom corners of lower front panel 2 Pull bottom of lower front panel forward then down see Figure 7 Methods For Attaching Mounting Bracket To Wall Only use last hole on each end of mounting b...

Страница 8: ...mounting bracket onto wall Line up last hole on each end of bracket with wall anchors 6 Insert mounting screws through bracket and into wall anchors 7 Tighten screws until mounting bracket is firmly f...

Страница 9: ...re regulator with wrench when connecting it to gas piping and or fittings CAUTION Use pipe joint sealant that is resistant to liquid petroleum LP gas Figure 14 Gas Connection The installer must supply...

Страница 10: ...ve to control valve see Figure 16 Apply mixture of liquid soap and water to gas joints Bubbles forming show a leak 5 Correct all leaks at once 6 Light heater see Operating Heater pages 10 and 11 for t...

Страница 11: ...ounterclockwise to desired heating Level The main burner should light Set control knob to any heat level between HI and LO This increases or decreases the burner flame height At times the room may exc...

Страница 12: ...near the floor If you smell gas STOP Follow B in the safety information on the side of heater If you can t smell gas go to the next step 5 Push in and turn control knob counterclockwise to PILOT posit...

Страница 13: ...sembly see Figure 25 With the unit off lightly blow air through the air inlet hole You may blow through a drinking straw if compressed air is not available Figure 25 Pilot Inlet Air Hole CLEANING HEA...

Страница 14: ...ff valve is not fully open 4 Thermocouple connection loose at control valve 5 Pilot flame is not touching thermocouple This allows thermocouple to cool causing pilot flame to go out This problem could...

Страница 15: ...ile heating or contracting while cooling 1 When heated vapors from furniture polish wax carpet cleaners etc turn into white powder residue REMEDY 1 Clean burner orifice see Cleaning and Maintenance pa...

Страница 16: ...ctions Page 10 2 Replace control valve 1 Take apart gas tubing and remove foreign matter 2 Locate and correct all leaks see Checking Gas Connections Page 10 1 This is common with most heaters if noise...

Страница 17: ...optional fan kit part HAB01 fits all models noted in this manual The fan has 3 settings ON OFF Auto The thermostatically controlled HAB01mproves heater efficiency and includes installation and operat...

Страница 18: ...1 8 ILLUSTRATED PARTS BREAKDOWN THERMOSTAT MODELS HB20TL HB30TL...

Страница 19: ...ass Retainer Lower Glass Retainer Self Tapping Screw Thermostat Valve Assembly Screws Thermostat Valve Base Ignitor Assembly Ignitor Line Pressure Regulator Washer Self Locking Screw Main Inlet Tube A...

Страница 20: ...2 0 ILLUSTRATED PARTS BREAKDOWN NON THERMOSTAT MODELS HB20ML HB30ML...

Страница 21: ...g Screw Control Valve Ignitor Line Control Knob Assembly Control Valve Fixed Nut Pressure Regulator Washer Self Locking Screw Main Inlet Tube Assembly ODS Line Assembly Lower Gas Outline Tube Assembly...

Страница 22: ...2 2...

Страница 23: ......

Страница 24: ......

Отзывы: