background image

3

PRODUCT FEATURES

SAFETY  DEVICE

A  standard  requirement for all vent-free  room
heaters.  This  heater has a pilot  with  an  Oxygen
Depletion  Sensor(ODS)  safety  shutoff  system.
The ODS/pilot  shuts  off  the heater  if  there  is
not  enough  fresh  air.

PIEZO  IGNITION  SYSTEM

This  heater  is  equipped  with  a  piezo  ignitor.
This  system  requires  no  matches, batteries, or
other  sources  to  light  heater.

THERMOSTATIC  HEAT
CONTROL  ON  THERMOSTAT
MODELS

These    heaters    have    a    control    valve    with    a
thermostat    sensing    bulb.  This    results    in    the
greatest    heater    comfort    and    may    result    in
lower  gas  bills.

Figure1-Vent-Free  Propane/LP  Gas  Heater

WAT E R   VA P O R :   A  B Y- P R O D U C T   O F   U N V E N T E D   R O O M   H E AT E R S

Water vapor is a by-product of gas combustion. An
unvented room heater produces approximately one
(1) ounce (30ml) of water for every 1,000 BTU’s
(.3KW’s) of gas input per hour.
Unvented room heaters are recommended as supple-
mental heat (a room) rather than a primary heat
source (an entire house). In most supplemental heat
applications, the water vapor does not create a
problem. In most applications, the water vapor en-
hances the low humidity atmosphere experienced
during cold weather.

Lower

Front

Panel

Heater

Cabinet

Control

Knob

Grill

Burners

LOCAL  CODES

Install  and  use  heater  with  care. Follow  all  local
codes. In  the  absence  of  local  codes, use   the
latest  edition  of  

National  Fuel  Gas Code ANSZ223.1,

also  known  as  NFPA  54*.
*Available  from :
        American  National  Standards Institute, Inc.

1430  Broadway

New York, NY 10018

National  Fire  Protection  Association, Inc.

Batterymarch  Park

Quincy, MA  02269

QUALIFIED  INSTALLING   AGENCY

Installation and replacement of  gas piping,   gas utiliza-
tion    equipment    or    accessories    and    repair      and
servicing  of equipment  shall be  performed  only  by   a
qualified  agency.  The  term  “qualified  agency”   means
any  individual,  firm ,  corporation,  or  company   that
either   in   person   or   through  a   representative  is
engaged  in  and  is  responsible   for  (a)  the  installation,
testing,  or  replacement  of  gas  piping  or  (b)    the
connection,  installation,  testing,  repair,  or  servicing  of
equipment ; that  is  experienced  in  such  work;  that is
familiar  with  all  precautions  required, and  that  has
complied with all the requirements of the authority hav-
ing  jurisdiction.

State of Massachsetts

:  The  installation  must  be

made  by  a  licensed  plumber  or  gas  fitter in  the
Commonwealth  of  Massachusetts .
Sellers  of  unvented  propane  or  natural  gas-fired
supplemental  room  heaters  shall  provide  to  each

purchaser a copy  of  527 CMR 30 upon  sale  of  the unit.

I

n the state of Massachusetts, unvented  propane or

nature gas-fired space heaters shall be prohibited in

bedrooms and bathrooms.

UNPACKING

1.   Remove  heater  from  carton.
2.  Remove  all  protective   packaging  applied  to

      heater  for  shipment.
3.   Check  heater  for  any  shipping  damage.  If  heater
     is damaged, promptly  inform  dealer  where  you
      bought  heater.

Ignitor

Button

The following steps will help insure that water vapor
does not become a problem.
1. Be sure the heater is sized properly for the
application, including ample combustion air and
circulation air.
2. If  high humidity is experienced, a dehumidifier
may be used to help lower the water vapor content
of the air.
3. Do not use an unvented room heater as the
primary heat source.

Содержание HB20ML-1

Страница 1: ...ust be performed by a qualified installer service agency or gas supplier HB20TL 1 HB30TL 1 HB20ML 1 HB30ML 1 Table of Contents ImportantSafetyInformation 2 Product Features 3 ProperVentilation FreshAi...

Страница 2: ...e of heater becomes very hot when running heater Keep children and adults away from hot surface to avoid burns or clothing ignition Heater will remain hot for a time after shuting down Allow surface t...

Страница 3: ...tion Inc Batterymarch Park Quincy MA 02269 QUALIFIED INSTALLING AGENCY Installation and replacement of gas piping gas utiliza tion equipment or accessories and repair and servicing of equipment shall...

Страница 4: ...of the methods described in the National Fuel Gas Code ANS Z223 1 Section 5 3 or applicable local codes Unusually Tight Construction The air that leaks around doors and windows may provide enough fre...

Страница 5: ...uel burning appliances in the space Vent free heater Btu Hr Gas water heater Btu Hr Gas furnace Btu Hr Vented gas heater Btu Hr Gas Fireplace logs Btu Hr Other gas appliances Btu Hr Total Btu Hr Do no...

Страница 6: ...pment shutoff valve ground joint union test gauge connection sediment trap tee joint pipe wrench A CSA AGA design certified equip ment shutoff valve with 1 8 NPT tap is an acceptable alternative to te...

Страница 7: ...s near bottom corners of lower front panel 2 Pull bottom of lower front panel forward then down see Figure 7 Methods For Attaching Mounting Bracket To Wall Only use last hole on each end of mounting b...

Страница 8: ...mounting bracket onto wall Line up last hole on each end of bracket with wall anchors 6 Insert mounting screws through bracket and into wall anchors 7 Tighten screws until mounting bracket is firmly f...

Страница 9: ...re regulator with wrench when connecting it to gas piping and or fittings CAUTION Use pipe joint sealant that is resistant to liquid petroleum LP gas Figure 14 Gas Connection The installer must supply...

Страница 10: ...ve to control valve see Figure 16 Apply mixture of liquid soap and water to gas joints Bubbles forming show a leak 5 Correct all leaks at once 6 Light heater see Operating Heater pages 10 and 11 for t...

Страница 11: ...ounterclockwise to desired heating Level The main burner should light Set control knob to any heat level between HI and LO This increases or decreases the burner flame height At times the room may exc...

Страница 12: ...near the floor If you smell gas STOP Follow B in the safety information on the side of heater If you can t smell gas go to the next step 5 Push in and turn control knob counterclockwise to PILOT posit...

Страница 13: ...sembly see Figure 25 With the unit off lightly blow air through the air inlet hole You may blow through a drinking straw if compressed air is not available Figure 25 Pilot Inlet Air Hole CLEANING HEA...

Страница 14: ...ff valve is not fully open 4 Thermocouple connection loose at control valve 5 Pilot flame is not touching thermocouple This allows thermocouple to cool causing pilot flame to go out This problem could...

Страница 15: ...ile heating or contracting while cooling 1 When heated vapors from furniture polish wax carpet cleaners etc turn into white powder residue REMEDY 1 Clean burner orifice see Cleaning and Maintenance pa...

Страница 16: ...ctions Page 10 2 Replace control valve 1 Take apart gas tubing and remove foreign matter 2 Locate and correct all leaks see Checking Gas Connections Page 10 1 This is common with most heaters if noise...

Страница 17: ...optional fan kit part HAB01 fits all models noted in this manual The fan has 3 settings ON OFF Auto The thermostatically controlled HAB01mproves heater efficiency and includes installation and operat...

Страница 18: ...1 8 ILLUSTRATED PARTS BREAKDOWN THERMOSTAT MODELS HB20TL HB30TL...

Страница 19: ...ass Retainer Lower Glass Retainer Self Tapping Screw Thermostat Valve Assembly Screws Thermostat Valve Base Ignitor Assembly Ignitor Line Pressure Regulator Washer Self Locking Screw Main Inlet Tube A...

Страница 20: ...2 0 ILLUSTRATED PARTS BREAKDOWN NON THERMOSTAT MODELS HB20ML HB30ML...

Страница 21: ...g Screw Control Valve Ignitor Line Control Knob Assembly Control Valve Fixed Nut Pressure Regulator Washer Self Locking Screw Main Inlet Tube Assembly ODS Line Assembly Lower Gas Outline Tube Assembly...

Страница 22: ...2 2...