REMOTE RECEIVER

ELECTRONIC MODULE

TR

TH

NEUTRAL WIRE

110/24VAC

TRANSFORMER

24VAC

HOT WIRE

120VAC

ANTENNA

LEARNING

BUTTON

SLIDE

SWITCH

OFF
REMOTE
ON

Wiring Electronic Spark Ignitions

The remote control receiver can be wired, in series, to a
24VAC transformer, which controls an electronic igni-
tion module (see Figure 3).

1. Connect the neutral wire from the 24VAC transformer

to the TR (transformer) terminal on the Electronic
Module.

2. Connect the hot wire from the 24VAC transformer to

either of the wires from the remote receiver.

3. Connect the other wire from the receiver to the TH

(thermostat) terminal on the Electronic Module.

Figure 3.  Wiring Electronic Spark Ignitions

The remote receiver has a 3-position slide switch: OFF/
REMOTE/ON (see Figure 4).

Figure 4.  Remote Receiver

NOTE: The remote receiver will only respond to
the transmitter when the 3-position slide button on
the remote receiver is in the Remote position. If
the system does not respond to the transmitter on
initial use, see section Matching Security Codes.

1. With the slide switch in the ON position, the system

is on.

2. With the slide switch in the REMOTE position, the

system only operates if the remote receiver receives
commands from the transmitter.

3. With the slide switch in the OFF position, the system

is off.

NOTE:

 The slide switch should be placed in the OFF

position if you will be away from your home for an ex-
tended period of time. Placing the switch in the OFF
position also functions as a safety “lock out” by turning
the system off and rendering the remote receiver inop-
erative.

TRANSMITTER

Important: Before operating remote control, trans-
mitter and receiver must have matching security
codes. See section ‘Matching Security Codes’.

Important:

 Review ‘Communication-Safety Features’

under ‘Transmitter Safety Features’ section. The com-
munication safety features shut down the fireplace sys-
tem when a potentially unsafe condition exists.

Important: 

Review ‘Auto Shutdown’ section. This

safety feature shuts down the fireplace after 9 hours of
continuous operation, in ON mode only.

Important:

 New or fully charged batteries are essen-

tial for proper operation of the multi-function transmit-
ter. The transmitter operates on 2 AAA-size 1.5V bat-
teries. Use Alkaline batteries for longer battery life and
maximum operational performance.

Insert 2 AAA-size 1.5V batteries into the battery com-
partment on the back of the transmitter. When the bat-
teries are correctly inserted, the screen will display
numbers (see Figure 5 for LCD Display Screen).

NOTE:

 If the transmitter is activated from a very cold

condition it may be necessary to allow the transmitter
to stabilize to room temperature (could take up to 15
minutes) before accurate room temperatures are dis-
played on the screen.

NOTE: 

LCD screen is equipped with a “backlite” for

easier viewing of LCD screen. Backlite illuminates when
a function button is depressed. After 5 seconds elapses,
LCD screen will return to its normal state.

Содержание SMART-STAT-II

Страница 1: ...BY THE PARTYRESPONSIBLE FOR COMPLIANCE COULD VOID THE USER S AUTHORITY TO OPERATE THE EQUIPMENT NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pu...

Страница 2: ...3 Using the wire nuts provided connect the service wires to the junction box The black wires to the black service wire the white wires to the white ser vice wire and the service ground wire to the gro...

Страница 3: ...ome for an ex tended period of time Placing the switch in the OFF position also functions as a safety lock out by turning the system off and rendering the remote receiver inop erative TRANSMITTER Impo...

Страница 4: ...rent time in AM PM 7 ROOM Indicates CURRENT room temperature 8 O F Indicates degrees Fahrenheit 0 C indicates degrees Celsius Transmitter Settings Flip open the plastic cover on the front of the trans...

Страница 5: ...nt repeated thermo cycling of the gas appliance the sensing unit in the transmitter will only activate the remote receiver when the temperature change exceeds 20 F 10 C above or below the SET desired...

Страница 6: ...teries in the TRANSMITTER to make sure the voltage is no less than 2 7 volts Auto Shutdown This remote control has an Auto Shutdown feature in corporated into its system When the transmitter MODE is i...

Страница 7: ...ion error whether performed by a con tractor service company or owner is not covered by this warranty Seller will not be responsible for labor charges and or damage incurred in installa tion repair re...

Отзывы: