REMOTE RECEIVER

Important: The remote receiver should be posi-
tioned close to front in right or left corner where
ambient temperatures do not exceed 170

F.

The remote receiver is powered by 110-120VAC. It plugs
into a standard polarized duplex receptacle.

Locating Receiver and Operating Functions

This remote receiver can be positioned under the fire-
box in the control compartment of the fireplace if ambi-
ent temperatures do not exceed 170

F. This system is

designed to remotely operate the gas valve.

INSTALLATION INSTRUCTIONS

Installing Electrical Service to the Junction Box

WARNING: TURN ELECTRICAL POWER OFF
AT THE CIRCUIT BREAKER BEFORE BEGIN-
NING THIS INSTALLATION.

NOTE: 

Some appliances do not have a cover plate.

Instead, there is a hole through which the Romex clamp
is attached to the outer wrap.

1. Remove the electrical cover plate from the lower

side of the fireplace. Remove the knock-out from
the plate and attach the Romex clamp (screws to
the outside) (see Figure 1).

2. Feed the electrical service wires through the Romex

clamp and secure the wires to the clamp.

3. Using the wire nuts provided, connect the service

wires to the junction box. The black wires to the
black service wire, the white wires to the white ser-
vice wire, and the service ground wire to the ground
stud of the junction box.

4. Re-attach the cover plate to the outside of the fire-

place.

WARNING: LEAVE ELECTRICAL POWER OFF
AT THIS TIME.  DO NOT RESTORE POWER UN-
TIL THE REMOTE CONTROL SYSTEM IS COM-
PLETELY INSTALLED.

ACCESS HOLE

COVER

PLATE

110 VAC
SERVICE

RECEIVER WIRING INSTRUCTIONS

Incorrect wiring connections WILL cause damage to the
gas valve or electronic module operating the gas appli-
ance and may also damage the remote receiver.

Wiring Millivolt Valves

Connect the remote receiver by connecting each of the
two wires leading from the remote receiver to either of
the two wire TH terminals on the gas valve (see Fig-
ure 2). Normally it does not matter which wires go to
which terminal.

Figure 2.  Wiring Millivolt Valves

Alternative Wiring for units with a wall switch

Disconnect the wall switch wire from the TH terminal on
the valve and connect this wire to male connector sup-
plied on the receiver. Connect remaining female con-
nector from receiver to the TH terminal on the valve.

REMOTE RECEIVER

TERMINAL BLOCK ON

MILLIVOLT GAS VALVES

THERMOPILE/

PILOT LIGHT

WALL

SWITCH

Содержание SMART-STAT-II

Страница 1: ...BY THE PARTYRESPONSIBLE FOR COMPLIANCE COULD VOID THE USER S AUTHORITY TO OPERATE THE EQUIPMENT NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pu...

Страница 2: ...3 Using the wire nuts provided connect the service wires to the junction box The black wires to the black service wire the white wires to the white ser vice wire and the service ground wire to the gro...

Страница 3: ...ome for an ex tended period of time Placing the switch in the OFF position also functions as a safety lock out by turning the system off and rendering the remote receiver inop erative TRANSMITTER Impo...

Страница 4: ...rent time in AM PM 7 ROOM Indicates CURRENT room temperature 8 O F Indicates degrees Fahrenheit 0 C indicates degrees Celsius Transmitter Settings Flip open the plastic cover on the front of the trans...

Страница 5: ...nt repeated thermo cycling of the gas appliance the sensing unit in the transmitter will only activate the remote receiver when the temperature change exceeds 20 F 10 C above or below the SET desired...

Страница 6: ...teries in the TRANSMITTER to make sure the voltage is no less than 2 7 volts Auto Shutdown This remote control has an Auto Shutdown feature in corporated into its system When the transmitter MODE is i...

Страница 7: ...ion error whether performed by a con tractor service company or owner is not covered by this warranty Seller will not be responsible for labor charges and or damage incurred in installa tion repair re...

Отзывы: