B.  Installing Vent Components

1.  Attach the First Vent Component to the

     Starting Collars

To attach the first vent component to the starting collars

of the fireplace:

• Apply a 3/8 inch (9.5mm) bead of stove cement around

the 5 inch (127mm) fireplace starting collar.

• Make sure that the fireplace rope gasket supplied with

the fireplace seals between the first 8-5/8 inch (219mm)

vent component and the outer fireplace wrap.

• Lock the vent components into place by sliding the con-

centric pipe sections with four (4) equally spaced interior

beads into the fireplace collar or previously installed com-

ponent end with four (4) equally spaced indented sections.

• When the internal beads of each 8-5/8 inch (219mm)

outer pipe line up, rotate the pipe section clockwise about

one-quarter (1/4) turn. The vent pipe is now locked together.

!

!

WARNING:  ENSURE  THAT  THE  FIBER-

GLASS  ROPE  GASKET  SUPPLIED  WITH

THE FIREPLACE SEALS BETWEEN THE FIRST

VENT COMPONENT AND THE OUTER FIREPLACE

WRAP.

If the installation is for a termination cap attached directly

to the fireplace, skip to the sections, 

Install Firestops

 and

Vent Termination

.

Figure 10.  Attaching the First Vent Component

                  to the Starting Collars

WARNING: A  3/8  INCH  (9.5  MM)  BEAD  O F

STOVE CEMENT MUST BE PLACED AROUND

THE 5 INCH (127 MM) FIREPLACE STARTING COL-

LAR BEFORE ATTACHING THE FIRST VENT COM-

PONENT.  FAILURE  TO  SEAL  THIS  JOINT  MAY

CAUSE THE FIREPLACE TO OPERATE IMPROPER-

LY. SEE THE DIAGRAM .

STARTING

COLLAR

STOVE

SEALANT

BEAD

1 INCH

(25.4mm)

 FIRST VENT

COMPONENT

 3/8”

(9.5mm)

Содержание Royal Fireplaces R-5500RHT

Страница 1: ...PPLIANCE FOR FUTURE REFERENCE 1 This appliance may be installed in an af termarket permanentlylocated manufac tured mobile home wherenotprohibited by local codes 2 Thisapplianceisonlyforusewiththetype...

Страница 2: ...he installation FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty Prior to the first firing of the fireplace READ the Using Your Firepla...

Страница 3: ...t System 11 A Vent System Approvals 11 B Installing Vent Components 15 C Vent Termination 19 Step 4 Positioning Leveling and Securing the Fireplace 22 Step 5 The Gas Control System 22 Step 6 The Gas S...

Страница 4: ...ates or to the CSAC22 1 Canadian Electric Code in Canada This model may be installed in a bedroom or bed sitting room in the U S A and Canada 1Approvals and Codes High Altitude Installations U L Liste...

Страница 5: ...lure to follow these instructions will void the own er s warranty and may present a fire hazard The Hearth Technologies Warranty will be voided by and Hearth Technologies disclaims any responsibility...

Страница 6: ...of the R 5500RHT 41 1043mm 38 965mm 36 1 8 916mm 25 642mm 34 5 8 879mm ELECTRICAL ACCESS 10 259mm 3 90mm GAS LINE ACCESS 2 1 8 55mm 6 7 8 174mm 14 362mm 8 5 8 219mm VENT COLLARS 21 1 2 548mm 11 5 8 2...

Страница 7: ...rance diagrams on pages 20 and 21 in this manual The distance from the unit to combustible construction is to be measured from the unit outer wrap surface to the combustible construction NOT from the...

Страница 8: ...r pipe DV 36D 5 3 4 146mm 8 3 4 222mm 11 3 4 298mm DV 48D 7 3 8 187mm 6 5 32 156mm 11 5 8 295mm 8 5 8 220mm 8 1 2 216mm 6 7 16 164mm 11 1 16 281mm 6 1 2 165mm 8 1 2 216mm 5 1 16 129mm 8 5 8 220mm 35 3...

Страница 9: ...d should be used in conjunction with this Installers Guide The flame and ember appear ance may vary based on the type of fuel burned and the venting configuration used Terminations Kits HORIZONTAL TER...

Страница 10: ...bow NOTE IF A 90o ELBOW IS FIRST AT TACHED TO THE UNIT THE MAXIMUM HORIZONTAL RUN IS 3 FEET 914mm VENTING WITH ONE 1 90 ELBOW V FT H FT 1 MIN 305mm 5 MAX 1 52m 2 MIN 610mm 10 MAX 3 1m 3 MIN 914mm 15 M...

Страница 11: ...MIN 305mm 5 MAX 1 52m 2 MIN 610mm 10 MAX 3 1m 3 MIN 914mm 15 MAX 4 65m 4 MIN 1 22m 20 MAX 6 2m V H H1 40 MAX 12 4m 20 MAX 6 2m V V1 H 40 MAX 12 4m Figure 8 Venting with Two 90 Elbows NOTE There MUST b...

Страница 12: ...914mm 15 MAX 4 65m 4 MIN 1 22m 20 MAX 6 2m NOTE H H1 20 MAX 6 2m V V1 H H1 40 MAX 12 4m VENTING WITH THREE 3 90 ELBOWS V FT H H1 FT 1 MIN 305mm 5 MAX 1 52m 2 MIN 610mm 10 MAX 3 1m 3 MIN 914Amm 15 MAX...

Страница 13: ...s When the internal beads of each 8 5 8 inch 219mm outer pipe line up rotate the pipe section clockwise about one quarter 1 4 turn Theventpipeisnowlockedtogether WARNING ENSURE THAT THE FIBER GLASS RO...

Страница 14: ...ay be installed and rotated to any point around the preceding component s vertical axis If an el bow does not end up in a locked position with the pre ceding component attach with a minimum of two 2 s...

Страница 15: ...mbustible wall To install firestops for horizontal runs that pass through either interior or exterior walls Cut a 12 inch by 12 inch 305mm X 305mm hole through the wall NOTE The center of the hole is...

Страница 16: ...11 inch 280mm X 280mm hole through the ceiling using the centerpoint previously marked Frame the hole with framing lumber the same size as the ceiling joists Figure 18 Ceiling Firestop Ceiling Side If...

Страница 17: ...of the wall firestop to secure the vent pipe in place For trapezoidal cap termination kits Using screws secure the cap to the exterior wall through the flanges in the cap Figure 20 Round Trapezoid Te...

Страница 18: ...or that may be opened C 9 U S A 12 Canada clearance to permanently closed window D 18 vertical clearance to ventilated soffit located above the termi nal within a horizontal distance of 2 feet 60 cm f...

Страница 19: ...EE FIGURE 22 FOR MINIMUM HEIGHTS PROVIDED THE TERMINATION CAP IS AT LEAST TWO 2 FEET FROMA VERTICAL WALL AND 2 FEET BELOW A HORIZONTAL OVERHANG NOTE This also pertains to vertical vent systems in stal...

Страница 20: ...ition level and secure the fireplace Figure 23 Proper Positioning Leveling and Securing of a Fireplace Figure 24 Gas Control System STANDING PILOT Step 5 The Gas Control System WARNING THIS UNIT IS NO...

Страница 21: ...nnect it to the shut off valve When attaching the pipe support the control so that the lines are not bent or torn After the gas line installation is complete use a soap solution to carefully check all...

Страница 22: ...itch in the desired position on a wall Run a maximum of 25 feet 7 8 m or less length of 18 A W G minimum wire and connect it to the fireplace ON OFF switch pigtails WARNING DO NOT CONNECT 110 120 VAC...

Страница 23: ...ontal Dimensions of Combustibles above Fireplace CAUTION IF JOINTS BETWEEN THE FINISHED WALLS AND THE FIREPLACE SURROUND TOP AND SIDES ARE SEALED A 300 F MINIMUM SEALANT MATE RIAL MUST BE USED THESE J...

Страница 24: ...sooting occurs the logs might need to be repositioned slightly to avoid excessive flame impingement Step 10 Installing Trim Logs and Ember Material Placing the Ember Material Ember material is shipped...

Страница 25: ...ate normally Subsequent lightings of the fireplace will not require this purging of air from the gas supply lines unless the gas valve has been turned to the OFF position in which case the air would h...

Страница 26: ...s Frequency Once annually By Qualified service technician Task Brush or vacuum the control compartment fireplace logs and burner areas surrounding the logs Checking Flame Patterns Flame Height Frequen...

Отзывы: