14
35020 Rev G
06-03
BCBR36 B-VENT GAS APPLIANCE
G. FINISHING
1. Combustible Finishing Material
Material made of or surfaced with wood, compressed
paper, plant fibers, plastics, or any material capable
of igniting and burning, whether flame proofed or not,
plastered or unplastered (this includes drywall).
2. Noncombustible Finishing Material
Material which will not ignite and burn. Such materials
are those consisting entirely of steel, iron, brick, tile,
concrete, slate, glass or plasters, or any combination
thereof, or have a UL fire rating of zero (0).
3. High Temperature Sealant Material
Sealants that will withstand high temperatures: General
Electric RTV103 (Black) or equivalent. Rutland, Inc.
Appliance Mortar #63, or equivalent.
A high temperature sealant, 1/8 wide minimum bead,
must be used to close off gaps between the appliance
and facing to prevent cold air leaks. See Figure 14.
A combustible mantel may be installed. Please refer
to Figure 3, page 6.
WARNING!
Air slots on this appliance cannot, in any way, be
covered as it may create a fire hazard.
H. APPLIANCE PREPARATION
Figure 14
Figure 16 - Control Access Panel Installation/
Removal
1. Appliance Preparation
The log set should look similar to that in Figure 26, page 21. Remove the control access panel from its shipping location
(Figure 15) by removing the two screws holding it in place. Replace the two screws. Put the control access panel in place
by sliding one end on the appliance bottom by means of slots in the control access panel. Slide the other end onto the
appliance bottom. See Figure 16.
Figure 15 - Control Access Panel Shipping Location