BCBR36 B-VENT GAS APPLIANCE
Note:
This appliance must be electrically wired and grounded in accordance
with local codes or, in the absence of local codes, with
National Electric Code
ANSI/NFPA 70-latest edition
or the
Canadian Electric Code, CSA C22l.1
.
Figure 11 - Intermittent Pilot Ignition Wiring Diagram
CAUTION:
Battery polarity must be correct or control module
damage will occur.
5.
5. Ignition System
This appliance is equipped with an intermittent pilot control valve which operates on a 3 volt system. See wiring
diagram, Figure 11.
The appliance is supplied with a battery pack and a 3 volt AC transformer, which requires the installation of the
supplied JK9 Junction Box Kit. It is highly recommended that the JK9 be installed at this time to avoid reconstruction.
The battery pack requires two D cell batteries (not included). Batteries cannot be placed in the battery pack while
using the 3 volt AC transformer. Conversely, the transformer must be unplugged if the battery pack is used.