Hearth & Home Quadra-Fire OUTFITTER-II Скачать руководство пользователя страница 23

23

02/22

8105-804C

Following correction of any Alarm, turn the dial control to the OFF position, wait 10 seconds and turn back to 

desired setting OR unplug the appliance, wait 10 seconds then restore power.

Alarm

(LED Flashing RED)

Possible Cause

Corrective Action

1 Red Flash: Empty Hopper Alarm

Hopper empty

Fill the hopper

Auger jam

Inspect the feed tube for jams

Vacuum switch not closing

Make sure firebox door is shut, vacuum 

hose is connected to switch and drop 

tube, wire connectors are connected to 

vacuum switch, control board, hopper 

switch, and safety snap disc. 

Hopper lid open

Close the hopper lid

Exhaust probe does not sense 

temperature

Secure the exhaust probe keeping its 

wire away from hot surfaces and clean 

the exhaust plenum

Snap disc tripped (#3)

Reset snap disc

Exhaust probe not attached to outlet

Inspect  the  exhaust  probe  to  see  if  it 

is securely attached to the side of the 

exhaust outlet - keeping its wire away 

from hot surfaces

Exhaust path is dirty

Clean  appliance  including  the  fire  pot, 

exhaust path, and venting system

2 Red Flashes: Exhaust Probe Fail

Not connected to the control board

Connect terminal end to control board

Failed component

Replace exhaust probe – securing it to 

exhaust blower housing – keeping wire 

away from hot surfaces

4 Red Flashes: Missed Ignition

Hopper empty

Fill the hopper

Feed motor doesn’t turn

Inspect  feed  motor  circuit  (hopper  lid 

must be closed, vacuum switch must 

be closed, snap disc closed, and feed 

motor must be plugged in) Clear jam in 

feed tube

Dirty appliance

Clean  appliance  including  the  fire  pot, 

exhaust path, and venting system

Igniter has no power or is defective

Check igniter lead connections or 

replace igniter

Exhaust probe not properly installed

Secure exhaust probe to exhaust 

blower housing – keeping its wire away 

from hot surfaces

Igniter chamber plugged with debris

Clean igniter chamber

8 Red Flashes: Exhaust Over-Temp

Feed Motor Locked On

Repair wire(s) and replace control 

board 

Non-approved fuel used

Only  use  wood  pellet  fuel.    Do  not 

enhance its performance with any other 

combustible substance.

Convection blower dirty

Clean impellers

Table 23.1

Содержание Quadra-Fire OUTFITTER-II

Страница 1: ...ors and liquids in the vicinity of this or any other appliance Do not over fire If appliance or chimney connector glows you are over firing Over firing will void your warranty Comply with all minimum...

Страница 2: ...n 76 mm C Side Wall Mur De C t Muro Lateral 9 in 229 mm CORNER INSTALLATION INSTALLATION DU COIN RINC N DE LA INSTALACI N D Side Wall Mur De C t Muro Lateral 3 in 76 mm Made in Vietnam Fabriqu en Viet...

Страница 3: ...lass Specifications 8 E Electrical Rating on high 8 F Mobile Home Approved 8 G Sleeping Room 8 H California Prop65 8 2 General Information A Fire Safety 9 B Combustible Non Combustible Materials 9 C F...

Страница 4: ...ccupancy date The term Lifetime in the table below is defined as 20 years from the beginning date of warranty coverage for gas appliances 10 years from the beginning date of warranty coverage for wood...

Страница 5: ...r forced air furnaces or other such causes 6 use of fuels other than those specified in the operation instructions 7 installation or use of components not supplied with the applicable Product or any o...

Страница 6: ...ions will cause the fire pot to overfill Set Up 1 Empty fire box of component packet and any other debris Run 1 While thermostat is in RUN mode the set temperature can be temporarily changed by pressi...

Страница 7: ...iency 87 5 HHV Tested Efficiency 81 9 EPA BTU Output 9 605 to 40 667 per hr BTU Input 11 676 to 49 207 per hr Vent Size 3 or 4 Type L or PL Hopper Capacity 130 lbs Fuel Premium Wood Pellets Weighted a...

Страница 8: ...ot limited to Warped air tube Deteriorated refractory brick retainers Deteriorated baffle and other interior components NOTE Hearth Home Technologies manufacturer of this appliance reserves the right...

Страница 9: ...e a high or low ash content Higher Ash Content Material Hardwoods with a high mineral content Fuel that contains bark Standard grade pellets or high ash pellets Lower Ash Content Material Most softwoo...

Страница 10: ...eral Operating Information HOT SURFACES Glass and other surfaces are hot during operation AND cool down Hot glass will cause burns Do not touch glass until it is cooled NEVER allow children to touch g...

Страница 11: ...Cleaning Fire pot in the General Maintenance section of Owner s Manual under Maintaining and Servicing the Appliance Attempt relighting sequence see Lighting Instructions Guide C Firepot Burn Down A...

Страница 12: ...ached a sufficient temperature 3 This blower transfers heat from your appliance into the room and will continue to run even after the appliance has shutdown It will turn off after the exhaust temperat...

Страница 13: ...ed metal object before touching the thermostat CONNECT THERMOSTAT WIRES TO APPLIANCE There is a 4 screw terminal block located on the back lower left corner of the stove directly above the power cord...

Страница 14: ...om temperature Amber Blinks Continuously Appliance is in the in shutdown sequence During shut down the blowers will shut off when the exhaust temperature has cooled Red 1x Empty Hopper Alarm This alar...

Страница 15: ...Quick Reference Maintenance Chart Follow the detailed instructions found in this section for each step listed as referenced in the chart below NOTICE These are recommendations Clean more frequently i...

Страница 16: ...to break up deposits inside the firepot and dispose in an approved container Depending on the quality of fuel used the front of the firepot may need to be removed for better access for cleaning c Use...

Страница 17: ...aning glass b Vacuum fly ash from glass and door rope c Use a damp paper towel or any non abrasive glass cleaner Wipe off with dry towel 4 Disposal of Ashes Frequency As needed By Homeowner Ashes shou...

Страница 18: ...Handle Inspection Frequency Monthly or prior to heating season By Homeowner The gasket between the glass and firebox should be inspected periodically to make sure there is a good seal 7 Cleaning the E...

Страница 19: ...here is incomplete combustion or if there is a shutdown or incorrect operation of the appliance it will lead to some soot formation This will collect in the exhaust venting system The venting chimney...

Страница 20: ...ands immediately Is there a place to lubricate the blowers to quiet them down The most often cause of noisy blowers is from the impellers becoming dirty over time See General Maintenance Cleaning unde...

Страница 21: ...Exhaust probe is not attached to outlet Exhaust probe is not plugged in to the board Exhaust probe is defective error code may result Clean firepot Check flue vent for obstruction Inspect and clean e...

Страница 22: ...d component Igniter does not turn off Igniter short circuit The fuse will be blown and upon replacement of the fuse the igniter will remain on when appliance has power Inspect wires blowers and power...

Страница 23: ...is dirty Clean appliance including the fire pot exhaust path and venting system 2 Red Flashes Exhaust Probe Fail Not connected to the control board Connect terminal end to control board Failed compone...

Страница 24: ...24 02 22 8105 804C Date of Service Performed By Description of Service A Maintenance and Service Log 6 6 Reference Materials...

Страница 25: ...vice Parts List Service Parts R OUTFITTER II Beginning Manufacturing Date Jul 2022 Ending Manufacturing Date Active Pellet Cabinet Style Stove 1 2 10 11 3 4 5 6 9 8 7 12 13 14 15 16 Part number list o...

Страница 26: ...10 Y 4 Snap disc Manual Reset SRV230 0080 Y 5 Door Assembly SRV8105 021 Y 5 1 Glass Assembly SRV8105 173 5 2 Rope Door 3 4 x 84 832 1680 5 3 Hinge Pins Pkg of 2 433 1590 2 5 4 Threaded Handle Assembly...

Страница 27: ...manual must be ordered from a dealer Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 16 Feed Assembly Kit SRV7077 014 Y 16 1 Feed Motor SRV7000 670 Y 16 2 Feed Shaft Bushing Pkg of 2 7000 600...

Страница 28: ...tions included Read understand and follow these instructions for safe installation and operation Leave this manual with party responsible for use and operation of this appliance We recommend that you...

Отзывы: