Venting Systems
A. Direct Connect with Outside Air
B. Direct Connect without Outside Air
NOTE:
In Canada, where passage through a wall or
partition of combustible construction is desired,
the installation shall conform to
CAN/CSA-B365
.
NOTE:
•
Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY.
• Illustrations/diagrams are not drawn to scale.
• Actual installation may vary due to individual
design preference.
Figure 18.2
Figure 18.2
Fire Risk.
Inspection of Chimney:
• Masonry chimney must be in
good condition.
• Meets minimum standard of
NFPA 211
• Factory-built chimney must be a minimum
6 inch (152mm)
UL103 HT
.
WARNING
CAUTION
Never draw outside combustion air from:
•
Wall, floor or ceiling cavity
• Enclosed space such as an attic or garage
NOTE:
In Canada, only a full reline is allowed per
ULC
S628-93, ORD ULC C1482-M1990
.
Outside Air through Rear Wall
NOTE:
• Use non-combustible materials
around exhaust vent pipe and
seal all edges with non-flammable
insulation such as fiberglass,
mineral wool or ceramic material.
• DO NOT use high temperature
caulking materials to seal any edge
to prevent future serviceability.