Hearth & Home Heatilator Eco Choice PS50-C Скачать руководство пользователя страница 2

2

June 18, 2019

7059-800B

HEATILATOR ECO-CHOICE PS50

Important Safety Information .............3

A. Appliance Certification

. . . . . . . . . . . . . . . . . . . . . . . 3

B. BTU & Efficiency Specifications

  . . . . . . . . . . . . . . . 3

C. Glass Specifications

  . . . . . . . . . . . . . . . . . . . . . . . . 4

D. Electrical Rating (on high) . . . . . . . . . . . . . . . . . . . . 4

E. Mobile Home Approved . . . . . . . . . . . . . . . . . . . . . . 4

F. Non-Combustible Materials

  . . . . . . . . . . . . . . . . . . . 4

G. Combustible Materials  . . . . . . . . . . . . . . . . . . . . . . 4

H. Sleeping Room

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

I. Stove Composition

  . . . . . . . . . . . . . . . . . . . . . . . . . . 4

J. California - Prop65

. . . . . . . . . . . . . . . . . . . . . . . . . . 4

Getting Started ....................................5

A. 

Design, Installation & Location Considerations 

. . . . . . . . .

5

B. Thermostat Wall Control Location

. . . . . . . . . . . . . .

6

C. Tools And Supplies Needed

  . . . . . . . . . . . . . . . . . .

6

D. Inspect Appliance and Components . . . . . . . . . . . .

6

E. Install Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Dimensions and Clearances ..............8

A. Appliance Dimensions . . . . . . . . . . . . . . . . . . . . . . . 8

B. Clearances to Combustibles (UL and ULC)

  . . . . . . 9

C. Hearth Pad Requirements

. . . . . . . . . . . . . . . . . . . 10

D. Alcove  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Vent Information ................................12

A. Venting Termination Minimum Requirements

  . . . . 12

B. Avoiding Smoke and Odors

. . . . . . . . . . . . . . . . . . 13

C. Negative Pressure

. . . . . . . . . . . . . . . . . . . . . . . . . 14

D. Draft  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

E. Chimney and Exhaust Connection  . . . . . . . . . . . . 14

F. Equivalent Feet of Pipe 

. . . . . . . . . . . . . . . . . . . . .

15

G. Pipe Selection Chart

. . . . . . . . . . . . . . . . . . . . . . .

15

Venting Systems ...............................16

A. Through The Wall

  . . . . . . . . . . . . . . . . . . . . . . . . .

16

B. Vertical into Existing Class A Chimney

  . . . . . . . . . 17

C. Vertical - Interior - Typical Installation

 . . . . . . . . . .  17

D. Through The Wall & Vertical - External

. . . . . . . . . 17

E. Masonry. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

F. Alternate Masonry

  . . . . . . . . . . . . . . . . . . . . . . . . . 18

Appliance Set-Up ..............................19

A. Outside Air Kit 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

B. Top Vent Adapter Installation

. . . . . . . . . . . . . . . . . 20

C. Rear Vent Adapter Installations. . . . . . . . . . . . . . . 20

D. Thermostat Installation

  . . . . . . . . . . . . . . . . . . . . . 20

Mobile Home Installation ..................21

Reference Materials ..........................22

A. 

Service & Maintenance Log

  . . . . . . . . . . . . . . . . . 22

B. 

Accessory List . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

TABLE OF CONTENTS

Safety Alert Key:

•  DANGER!

 Indicates a hazardous situation which, if not avoided will result in death or serious injury.

•  WARNING!

 Indicates a hazardous situation which, if not avoided could result in death or serious injury.

•  CAUTION!

 Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

•  NOTICE:

 Indicates practices which may cause damage to the appliance or to property.

Heatilator Eco Choice is a registered trademark of Hearth & Home Technologies.

Содержание Heatilator Eco Choice PS50-C

Страница 1: ...ay cause house fire HOT SURFACES Glass and other surfaces are hot during operation AND cool down WARNING Hot glass will cause burns Do not touch glass until it is cooled NEVER allow children to touch...

Страница 2: ...haust Connection 14 F Equivalent Feet of Pipe 15 G Pipe Selection Chart 15 5 Venting Systems 16 A Through The Wall 16 B Vertical into Existing Class A Chimney 17 C Vertical Interior Typical Installati...

Страница 3: ...put 7 500 to 36 600 per hr BTU Input 13 100 to 49 900 per hr Vent Size 3 or 4 inches L or PL Hopper Capacity 83 lbs Fuel Premium Wood Pellets Weighted average LHV Low Heating Value efficiency using da...

Страница 4: ...gnite and burn composed of any combination of the following Steel Plaster Brick Iron Concrete Tile Glass Slate Materials reported as passing ASTM E 136 Standard Test Method for Behavior of Metals in a...

Страница 5: ...CAUTION If burning shelled field corn you must use approved venting specifically designed for corn to prevent corrosion or degradation Follow the instructions from the venting manufacturer NOTICE Chec...

Страница 6: ...carefully during the installation to ensure maximum safety and benefit Follow pipe manufacturer instructions for installation and air clearance requirements Reciprocating Saw Channel Locks Hammer Phi...

Страница 7: ...llation and copying this checklist for your file That this checklist remain visible at all times on the appliance until the installation is complete Electrical 120 VAC unswitched power provided to the...

Страница 8: ...Top View Figure 8 3 Side View Figure 8 4 Side View with Top Vent Adapter 24 1 4 616 24 1 4 616 26 7 16 672 28 5 16 719 9 3 4 248 2 3 8 60 20 1 4 514 32 813 35 3 4 908 10 11 16 272 23 1 4 591 3 1 8 79...

Страница 9: ...Installation Inches Millimeters D Back Wall to Adapter 1 25 E Side Wall to Appliance 14 356 F Back Wall to Appliance 6 1 4 159 Corner Installation Inches Millimeters G Walls to Appliance 2 51 Vertical...

Страница 10: ...end 51mm beyond each side of pipe shaded area to the wall thimble 152mm Front of glass 348mm USA INSTALLATIONS A non combustible floor protection is recommended extending beneath the flue pipe when in...

Страница 11: ...53 1346 n a n a C Depth n a n a 48 1219 D Side Wall 14 356 n a n a E Top 16 533 n a n a F Mantel Depth n a n a 36 914 Installations Into Alcove All minimums listed are to a combustible surface NOTE Il...

Страница 12: ...pi ces d passant de la structure P 305 mm 12 po D gagements au dessus du toit pour les abat vents verticaux Tous les d gagements minimum correspondent une installation avec un ensemble de prise d air...

Страница 13: ...emand House demand may consume the air needed for the appliance It may be necessary to add additional ventilation to the space in which the pellet appliance is located Consult with your local HVAC pro...

Страница 14: ...combustion byproducts are exiting the home through the chimney Install through the warm airspace enclosed by the building envelope This helps to produce more draft especially during lighting and die...

Страница 15: ...this installation Figure 15 2 1 Locate the calculated equivalent feet of pipe on the vertical left side of the chart 2 Move to the right horizontally on the chart until you reach your altitude above...

Страница 16: ...oose which one is best for your installation 2 in 51mm Minimum 2 in 51mm Minimum 6 in 152mm Minimum 6 in 152mm Minimum Figure 16 2 5 Venting Systems NOTE In Canada where passage through a wall or part...

Страница 17: ...installation instructions for all reduced air clearances installations B Vertical into Existing Class A Chimney Firestop Flashing Rain Cap 6 in 152mm Minimum Non combustible Hearth Pad 3 in 76mm Mini...

Страница 18: ...Minimum Fireclay Flue Liner with Airspace Concrete Cap Non combustible Hearth Pad Airtight Clean Out Door Clean Out cover Sheathing 3 in 76mm Minimum 1 in 25mm Clearance Flashing Fireclay flue Liner...

Страница 19: ...ters and hole saw or jig saw 1 Measure distance from floor to air vent opening in appliance and mark location on wall 2 Use a saw to cut opening in wall 2 inch kit Cut a 2 1 2 to 3 inch opening on ins...

Страница 20: ...iate position 3 Install the vent pipe into the adapter be sure to silicone all joints Clean Out Cover Clean Out Cover Figure 20 2 Rear Vent Adapter Figure 20 3 Rear to Top Vent Adapter 90 D Thermostat...

Страница 21: ...24 Spark Arestor Cap Roof Flashing Storm Collar Joist Shield Firestop Double Wall Connector Pipe Figure 21 1 CAUTION THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR WALL AND CEILING ROOF MUST BE MAI...

Страница 22: ...22 June 18 2019 7059 800B HEATILATOR ECO CHOICE PS50 A Service Maintenance Log 8 Reference Materials Date of Service Performed By Description of Service...

Страница 23: ...Wire 230 0810 Power Cord 812 1180 Y Thermostat Mechanical 812 3760 Y Paint Touch Up 3 42 19905 Hose Vacuum 5 32 Id 3 Ft SRV240 0450 Y Reset Button Assembly SRV7000 040 Baffle Center Back SRV7058 166...

Страница 24: ...ate purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ D...

Отзывы: