16
June 18, 2019
7059-800B
HEATILATOR ECO-CHOICE PS50
A. Through The Wall
Horizontal termination cap must be a minimum of 6
inches. (152mm) from the wall. Approved for mobile home
installations. Must use 3 or 4 inch (76-102mm) “L” or “PL”
listed pellet venting or Listed double wall pipe and an
authorized Outside Air Kit in mobile homes.
Figure 16.1
6 in.
(152mm)
Minimum
Non-combustible Hearth Pad
Wall
Thimble
Horizontal
Termination
Cap
2 in.
(51mm)
Minimum
6 in.
(152mm)
Minimum
From Glass
Wall
Thimble
Illustration shows venting going in both directions.
Choose which one is best for your installation.
2 in. (51mm)
Minimum
2 in.
(51mm)
Minimum
6 in (152mm) Minimum
6 in (152mm)
Minimum
Figure 16.2
5
Venting Systems
NOTE:
In Canada, where passage through a wall or
partition of combustible construction is desired,
the installation shall conform to CAN/CSA-B365
NOTICE:
Please note that while the minimum clearance for
the termination cap is 6 inches (152mm) there is the
possibility of soot build-up around the termination area.
If this occurs we suggest to move the termination further
away from the house to prevent it.
We strongly recommend that you DO NOT DOWNWARD
VENT.
The following may occur:
•
The appliance will not vent properly
•
Smoke spillage in the house
• Excessive sooting
CAUTION
Straight Out
45 Degree