June 17, 2019
7058-803B
5
ECO CHOICE PELLET
A . Plug in stove with no response
1. Check the power supply for 115 volts
2. Check the fuse in the junction box (7amps)
3.
Check snap disc #3 for power
4. Check control box
B. Call light on with no fire and no fuel in fire pot
1. Check hopper for bridging of pellets
2. Push reset button and adjust feed adjustment plate
3. Check thermocouple
4. Check venting system for obstructions
5. Check vacuum switch and vacuum hose
6. Check feed motor
7. Check exhaust blower
C. Call light on with no fire and partially burned fuel
in fire pot
1.
Check firepot and clean
2. Check thermocouple
-
Green light
- 2.7 mV (±.5mV)
-
Red light
- 12.1 mV (± 1mV)
3. Check initial feed time (54 - 60 seconds)
D. Call light is on with no fire and fuel in the fire pot
1.
Check firepot for “clinker” material
2.
Clean firepot
3. Check igniter
4. Check control box
E . Slow or smoky start-up
1.
Clean firepot
2. Feed adjustment plate may be set too high
3. Check exhaust blower and heat exchanger
G . Feed system fails to start
1. Check front door and make sure it is closed
2. Check to see if the call light is on
3.
Check the thermostat, #2 snap disc, and
hopper switch
4. Check feed motor and vacuum switch
5. Check exhaust system for obstructions
H . Thermostat will not start appliance
1. Check the power to the stove
2. Check the thermostat wires for continuity
3. Check the hopper switch
4. Check the reset button
5. Check the control box
F . Stove Runs for 18 minutes then stops feeding fuel
1. Check thermocouple
-
Green light
- 2.7 mVDC (±.5mV)
-
Red light
- 12.1 mVDC (± 1mV)
2.
Adjust feed adjustment plate for larger fire
3. Check thermocouple cover
- Cover needs to touch the end of the
thermocouple wire
-
Cover should extend 1 inch into the firepot
4. Check the control box
2
Basic Troubleshooting & Repair
I. Appliance fails to shut off
1. Check the thermostat and thermostat wire
2. Check the junction box and wire harness
3. Check the control box
J . Convection blower keep running or fails to start
1.
Check the #1 snap disc
2. Check convection blower
3.
Check for voltage to the #1 snap disc
K. Appliance cycles on and off with the thermostat is
always on
1. Check the control box
2. Check the vacuum switch or hopper switch
3. Check wiring for loose connections
L. Large fire, ash build up and dirty glass
1.
Check firepot, may need to be cleaned
2. Clean exhaust and heat exchanger system
3. Adjust feed adjustment plate in the hopper
4. Check control box feed times:
M . Appliance ignites then goes out but call light is
still on
“STOVE IS INCONSISTENT IN OPERATION“
1. Inspect thermocouple and its position over the pot
2. Check the feed motor
3.
Adjust feed adjustment plate for a larger fire
4. Check the exhaust and heat exchanger system
5. Check the vacuum switch
“ON” TIMES
PS35
PS50 & CAB50
SETTING
SECONDS
SECONDS
LOW
0.9
1.1
MEDIUM
1.6
1.9
HIGH
2.2
2.7