B. Good Faith Wall Surface
NOTICE:
Surface temperatures listed above are taken with
a temperature measuring probe as prescribed by the test
standard used for appliance certification. Temperatures
on walls or mantels taken with an infrared thermometer
may yield increased temperatures of up to 30
°
F (17
°
C) or
more depending on the thermometer settings and material
characteristics being measured. Use appropriate finishing
materials that are able to withstand these conditions. For
additional finishing guidelines, see Section 10.
If installing a television (TV) above the appliance, see
Section 3 of the appliance Owner’s Manual.
Figure 2.2 Good Faith Wall Surface Temperatures Above Appliance
(ECHEL60IN-C, ECHEL72IN-C)
MEASUREMENTS FROM
TOP EDGE OF THE OPENING
6 in.
18 in.
24 in.
30 in.
36 in.
48 in.
TO CEILING
42 in.
12 in.
245°F
APPLIANCE FRONT
190°F
155°F
140°F
135°F
125°F
125°F
FIREPLACE
OPENING
FACTORY-SUPPLIED NON-COMBUSTIBLE
BOARD SHOWN INSTALLED.
Figure 2.3 Good Faith Wall Surface Temperatures Above Appliance
with Passive Heat Kit Installed
Figure 2.1 Good Faith Wall Surface Temperatures Above Appliance
(ECHEL36IN-C/ECHEL36STIN-C, ECHEL48IN-C, ECHEL48STIN-C)
MEASUREMENTS FROM
TOP EDGE OF THE OPENING
6 in.
18 in.
24 in.
30 in.
36 in.
48 in.
42 in.
12 in.
144°F
APPLIANCE FRONT
120°F
115°F
105°F
95°F
95°F
95°F
95°F
FIREPLACE
OPENING
FACTORY-SUPPLIED NON-COMBUSTIBLE
BOARD SHOWN INSTALLED.
OPTIONAL PASSIVE HEAT KIT INSTALLED
APPLIANCE FRONT
MEASUREMENTS FROM
TOP EDGE OF THE FIREPLACE
OPENING
6 in.
18 in.
24 in.
30 in.
36 in.
48 in.
TO CEILING
42 in.
12 in.
170°F
155°F
145°F
140°F
130°F
125°F
125°F
FACTORY-SUPPLIED NON-COMBUSTIBLE
BOARD SHOWN INSTALLED.
FIREPLACE
OPENING
The ECHELON-C models may be installed with or without
optional heat management systems, including the Pas
-
sive Heat kit. The installation of a heat management sys
-
tem will affect certain aspects of the appliance installation
including framing dimensions and clearances to combus
-
tibles. Note that Figure 2.3 in this section refers to the
wall surface temperatures when the Passive Heat kit is
installed.