25
Step 4. Positioning, Leveling, and
Securing the Fireplace
• Place the fireplace into position.
• Level the fireplace from side to side and front to back.
• Shim the fireplace with non-combustible material, such
as sheet metal, as necessary.
• Secure the fireplace to the framing by nailing or screwing.
!
!
The diagram below shows how to properly position, level,
and secure the fireplace.
Figure 31. Proper Positioning,
Leveling and Securing of a Fireplace
Figure 32. Gas Controls Systems
Step 5. The Gas Control Systems
WARNING: THIS UNIT IS NOT FOR USE WITH
SOLID FUEL.
Two types of gas control systems are used with these models:
Standing Pilot Ignition
and
Intermittent Pilot Ignition (IPI).
Standing Pilot Ignition System
This system includes millivolt control valve, standing pilot,
thermopile/thermocouple flame sensor, and piezo ignitor.
WARNING: 110-120 VAC MUST NEVER BE
CONNECTED TO A CONTROL VALVE IN A
MILLIVOLT SYSTEM.
Intermittent Pilot Ignition (IPI) System
This system includes a 3V control valve, electronic module
and intermittent pilot.
INTERMITTENT PILOT IGNITION
NAILING TABS
(BOTH SIDES)