background image

1

- Do not store or  use gasoline or other flam-

mable vapors and liquids in the vicinity of this
or any other appliance.

-

What to do if you smell gas

• Do not try to light any appliance.

• Do not touch any electrical switch.

• Do not use any phone in your building.

• Immediately call your gas supplier from a

neighbor's phone. Follow the gas supplier's
instructions.

• If you cannot reach your gas supplier, call

the fire department.

- Installation and service must be performed by a

qualified installer, service agency, or the gas
supplier.

Installers Guide

WARNING: IMPROPER INSTALLA-
TION,  ADJUSTMENT,  ALTERATION,
SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAM-
AGE. REFER TO THIS MANUAL. FOR
ASSISTANCE OR ADDITIONAL INFOR-
MATION CONSULT  A QUALIFIED IN-
STALLER, SERVICE AGENCY, OR THE
GAS SUPPLIER.

Underwriters

Laboratories Listed

381-900I   1/03

READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS 

INSTALLERS

GUIDE 

MUST BE LEFT WITH APPLIANCE FOR

FUTURE REFERENCE.

1. This appliance may be installed in an af-

termarket, permanently located, manufac-
tured (mobile) home, where not prohibited
by local codes.

2. This appliance is only for use with the type

of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certified kit is used.

Please contact your Hearth & Home Technologies  dealer with
any questions or concerns. For the number of your nearest Hearth
& Home Technologies dealer, please call 1-888-427-3973.

Printed in U.S.A.   Copyright 2003

Hearth & Home Technologies Inc.
20802 Kensington Blvd., Lakeville, MN 55044

WARNING: IF THE INFORMATION
IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUS-
ING PROPERTY DAMAGE, PER-
SONAL INJURY, OR DEATH.

This product is covered by one or more of the following patents: (United States) 4,112,913; 4,408,594; 4,422,426; 4,424,792; 4,520,791; 4,793,322;
4,852,548; 4,875,464; 5,000,162; 5,016,609; 5,076,254 5,191,877; 5,218,953; 5,328,356; 5,429,495; 5,452,708; 5,542,407; 5,613,487; (Australia)
543790; 586383; (Canada) 1,123,296; 1,297,746; 2,195,264; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending.

Model:

BE-41B

Содержание BE-41B

Страница 1: ...REFERENCE 1 This appliance may be installed in an af termarket permanentlylocated manufac tured mobile home wherenotprohibited by local codes 2 This appliance is only for use with the type of gas ind...

Страница 2: ...DERSTAND all instructions carefully before starting the installation FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty Prior to the firs...

Страница 3: ...3 Installing the Vent System 12 A Vent System Approvals 12 B Installing Vent Components 19 C Vent Termination 22 Step 4 Positioning Leveling and Securing the Fireplace 25 Step 5 The Gas Control System...

Страница 4: ...e des num ros de pi ce se trouve la page suivante 2 3 1 8 9 10 5 7 6 Log Set Assembly 4 NG LP Exploded Parts Diagram GN PL Vue clat e des pi ces Service Parts BE 41B Beginning Manufacturing Date 5 02...

Страница 5: ...0 523 Pilot Assembly NG Module de veilleuse GN 485 510A Pilot Assembly LP Module de veilleuse PL 485 511A Thermocouple Thermocouple 446 511 Thermopile Thermopile 060 512 Intermittent Pilot Ignition Pa...

Страница 6: ...ce with local codes or in the absence of local codes with the National Electric Code ANSI NFPA No 70 in the United States or to the CSA C22 1 Canadian Electric Code in Canada These models may be insta...

Страница 7: ...to follow these instructions will void the owner s warranty and may present a fire hazard The Hearth Home Technologies Warranty will be voided by and Hearth Home Technologies disclaims any responsibil...

Страница 8: ...LS RATING PLATE AND LABELS LOWER LOUVER HOOD TOP STANDOFFS TOP LOUVER 41 1043mm 38 965mm 36 1 8 916mm 25 642mm 34 5 8 879mm 8 5 8 219mm VENT COLLARS ELECTRICAL ACCESS 26 7 8 683mm 10 259mm 3 90mm GAS...

Страница 9: ...THESE INSTRUCTIONS ARE NOT SUBSTITUTES FOR THE REQUIREMENTS OF LOCAL BUILDING CODES THEREFORE YOUR LOCAL BUILD ING CODES MUST BE CHECKED TO DETERMINE THE REQUIREMENTS FOR THESE STEPS Factory built fir...

Страница 10: ...ng material The dia gram below shows framing reference dimensions CAUTION MEASURE FIREPLACE DIMENSIONS AND VERIFY FRAMING METHODS AND WALL COVERING DETAILS BEFORE FRAMING 1 2 CLEARANCE FROM BACK OF FI...

Страница 11: ...36D 5 3 4 146mm 8 3 4 222mm 11 3 4 298mm DV 48D 7 3 8 187mm 6 5 32 156mm 11 5 8 295mm 8 5 8 220mm 8 1 2 216mm 6 7 16 164mm 11 1 16 281mm 6 1 2 165mm 8 1 2 216mm 5 1 16 129mm 8 5 8 220mm 35 3 4 908mm...

Страница 12: ...dentifying Vent Components The vent systems installed on this gas fireplace may in clude one two or three 90 elbow assemblies The rela tionships of vertical rise to horizontal run in vent configura ti...

Страница 13: ...want to install the vertical baffle 385 128 See flue restrictor installation in structions Figure 6 Flex Vent The flex vent must be supported with the spacing between support intervals not exceeding...

Страница 14: ...tem with the chart to find the appropriate position to set the Flue Restrictor 1 2 3 4 5 SETTINGS 1 2 3 4 5 Figure 10 CHART Vertical Top Vent NG Top Vent LP Rear Vent NG Rear Vent LP 4 1 1 No Restrict...

Страница 15: ...914mm 15 MAX 4 65m 4 MIN 1 22m 20 MAX 6 2m V H 40 MAX 12 4MM H 20 MAX 6 2m Figure 13 Venting with One 90 Elbow NOTE If a 90o elbow is first attached to the unit the maximum horizontal run is 3 feet 91...

Страница 16: ...Venting with Two 90 Elbows VENTING WITH TWO 2 90o ELBOWS V FT H H1 FT 1 MIN 305mm 5 MAX 1 52m 2 MIN 610mm 10 MAX 3 1m 3 MIN 914mm 15 MAX 4 65m 4 MIN 1 22m 20 MAX 6 2m V H H1 40 MAX 12 4m H H1 20 MAX 6...

Страница 17: ...V H H1 H2 40 MAX 12 4 m H 8 MAX 2 48 m H H 1 H2 20 MAX 6 2 m V H H H1 H2 1 MIN 305mm 2 MAX 610mm 5 MAX 1 52m 2 MIN 610mm 4 MAX 1 22m 10 MAX 3 1m 3 MIN 914mm 6 MAX 1 86m 15 MAX 4 65m 4 MIN 1 22m 8 MAX...

Страница 18: ...1 H H1 40 MAX 12 4m V FT H H1 FT 1 MIN 305mm 5 MAX 1 52m 2 MIN 610mm 10 MAX 3 1m 3 MIN 914mm 15 MAX 4 65m 4 MIN 1 22m 20 MAX 6 2m H H1 20 MAX 6 2m NOTE V V1 H H1 40 MAX 12 4m Figure 17 Venting with th...

Страница 19: ...erglass gasket supplied in the man ual bag seals between the first 8 5 8 inch 219mm vent component and the outer fireplace wrap Using 2 self tapping screws from the manual bag secure that gasket to th...

Страница 20: ...l brackets to the vent pipe and secure the wall bracket to the framing members with nails or screws Figure 22 Installing Support Brackets 4 Install Firestops For Horizontal Runs Firestops are REQUIRED...

Страница 21: ...ical runs that pass through ceilings Position a plumb bob directly over the center of the verti cal vent component Mark the ceiling to establish the centerpoint of the vent Drill a hole or drive a nai...

Страница 22: ...E WALL VENTING TERMINALS SHALL NOT BE RE CESSED INTO AWALL OR SIDING SEE THE FOL LOWING DIAGRAM FOR VENT TERMINATION CLEARANCES TRAPEZOID CAP TERMINATION 7 1 4 184mm WARNING THETERMINATIONCAPMUSTBEPO...

Страница 23: ...RONGLY RECOMMENDED WHENEVER POSSIBLE TO USE THE VINYL PROTECTOR KIT 30 minimum for vinyl clad soffits a vent shall not terminate directly above a sidewalk or paved driveway which is located between tw...

Страница 24: ...FOLLOWING DIAGRAM FOR MINIMUM HEIGHTS PROVIDED THE TERMI NATION CAP IS AT LEAST TWO 2 FEET FROM A VERTICAL WALLAND 2 FEET BELOW AHORIZON TAL OVERHANG NOTE This also pertains to vertical vent systems...

Страница 25: ...Figure 32 Gas Controls Systems Step 5 The Gas Control Systems WARNING THIS UNIT IS NOT FOR USE WITH SOLID FUEL Two types of gas control systems are used with these models Standing Pilot Ignition and...

Страница 26: ...h non combustible insulation to pre vent cold air infiltration Open the fireplace lower grille insert the gas supply line throughthegaslinehole andconnectittotheshut offvalve When attaching the pipe s...

Страница 27: ...witch Position the wall switch in the desired position on a wall Run a maximum of 25 feet 7 8 m or less length of 18 A W G minimum wire and connect it to the fireplace ON OFF switch pigtails WARNING D...

Страница 28: ...nstalled junction box before the fire place is permanently installed Wall Switch Position the wall switch in the desired position on a wall Run a maximum of 25 feet 7 8 m or less length of 18 A W G mi...

Страница 29: ...GAtesting standards donot require hearth extensions for gas fireplace appliances Figure 38 Sealant Material 2 4 5 6 7 8 9 2 3 4 5 12 11 10 9 8 7 6 TOP FRONT EDGE OF FIREPLACE 3 11 12 10 31 CEILING 1 1...

Страница 30: ...of the tie in the fireplace see Figure 40 WARNING USE WIRE CUT TERS DO NOT ATTEMPT TO CUT THE TIE WITH A KNIFE 3 Grasp the log assembly by the ends Do NOT grasp the log as sembly by the center Remove...

Страница 31: ...ut shrink wrap and remove from around the log assembly WARNING REMOVE ALL PACKAGING FROM LOGS 8 Install embers See ember placement instructions for details WARNING USE DIME SIZE PIECES ONLY DO NOT COV...

Страница 32: ...er material is shipped with this gas fireplace To place the ember material Pull the four glass latches out of the groove on the glass frame Remove glass door from the unit see Figure 44 Place dime siz...

Страница 33: ...e thermopile thermocouple tips should be covered with flame See Figure 32 Figure 46 Burner Flame Patterns MAKE SURE THE FLAMES ARE STEADY NOT LIFTING OR FLOATING Checking Vent System Frequency Before...