7
Hearth & Home Technologies •
PHFR-MCE-36, PHFR-MCE-48, PHFR-MCE-60, PHFR-MCE-72
Instructions • 2560-972 • 6/20
9. Install collars over the openings using hurricane
screws provided in the kit. PHFR-MCE-36 and PHFR-
MCE-48 kits must be installed on the two inside pas-
sive heat knockouts. Outer knockouts may be used
for alternate heat management systems. See Figure
5.10 and 5.11.
PHFR-MCE-60 and PHFR-MCE-72 kits must be in-
stalled on all four passive heat knockouts. One ad-
ditional heat management system may be used in
conjunction with the Ducted Passive Heat kit. If an
additional heat management system (HEAT-OUT-
GAS, HEAT-ZONE-GAS) is installed, that system
must use one of the outer (left or right) knockouts
while the other three must be maintained for connec-
tion to the Ducted Passive Heat kit.
Only one passive heat option may be installed on
a single appliance. Passive Heat kits without ducts
may not be used in conjunction with the Ducted Pas-
sive Heat kit.
Install Plenums and Flexible Duct
Figure 5.10 Ducted Passive Heat Front Discharge Configuration
COLLAR LOCATIONS
FOR 36 AND 48 INCH MODELS
Figure 5.11 Remove Passive Heat Knockouts
WARNING! Risk of Fire!
DO NOT remove appliance
heat management knock-outs unless an approved
heat management system is installed. Appliance and
combustible materials will overheat.
PHFR-MCE-36
PHFR-MCE-48
PHFR-MCE-60
PHFR-MCE-72
DUCTED PASSIVE HEAT
(Front Discharge*)
*Only one passive heat option may be installed on a single appliance.
Ductless passive heat kits may not be used in conjuction with the ducted passive heat kits.
One outside heat management knockout may be used for alternate heat management
(HEAT-ZONE-GAS, HEAT-OUT-GAS)
On 60 & 72 one outside (far left or far right) heat management knockout
may be used for an alternate heat management system
(HEAT-OUT-GAS, HEAT-ZONE-GAS)
On 36 & 48 the outside heat management knockouts
may be used for an alternate heat management systems
(HEAT-OUT-GAS, HEAT-ZONE-GAS)