![Hearth and Home Technologies Outdoor Lifestyles ODLANAIGST-48 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/hearth-and-home-technologies/outdoor-lifestyles-odlanaigst-48/outdoor-lifestyles-odlanaigst-48_installation-manual_2114499009.webp)
9
Outdoor Lifestyles by Hearth & Home Technologies Inc. • Lanai 48 See Thru Installation Manual • 4113-901 Rev. D • 8/21
Combustible materials
allowed in shaded areas
*39 in. min.
(990 mm)
to ceiling
Combustible Object
36 in.
(914 mm)
*Measured from top
of firebox opening
25 in.
(635 mm)
39-3/4 in.
(1009)
33-1/4 in.
(844mm)
8” Cement Board (supplied for
minimum height installations)
Extends above minimum
framing dimensions.
36 in. minimum
(914 mm)
to combustible
object
Notice: Flash the perimeter of the appliance, corners
and the appliance face in a manner consistent with
regional practices as required to prevent water
penetration around the appliance. See Section 3.F.
for more information regarding wall and enclosure
construction.
Notice: Vinyl siding must
not be placed between the
appliance opening and the
ceiling/overhang.
1/2 in
(13 mm)
52-1/8 in
(1324 mm)
11-5/8 in
(295 mm)
Note: For actual appliance dimensions refer to
Section 3.A.
Figure 3.2.
Appliance Locations and Framing Dimensions - ODLANAIGST-48
ODLANAIGST-48
NOTICE: Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY. Illustrations/