background image

Hearth & Home Technologies • Fireside Burner/Hearth Kits • 4004-304 Rev C • 08/2010

10

E. Install the Logs

F. Adjust the Burner Flame

•  The burner flame can be adjusted at the manual shutoff 

valve  beside  the  fireplace  to  obtain  the  desired  flame 

appearance. 

•  The  flame  color  will  stabilize  after  ten  minutes  of 

operation.

G. Inspect the Venting System

The fireplace venting system is designed and constructed to 

develop a positive flow adequate to remove flue gases to the 

outside atmosphere. See fireplace installation instructions.

A  spillage test must be made before the installed 

appliance is left with the consumer

  Close all doors and windows in the home.

  Light the log set.

  After  three  minutes,  test  with  a  smoke  match,  smoke 

candle, stick incense or cigarette one inch below the top of 

the opening (lintel) moving across the full width. If spillage 

(smoke drawn into the room) occurs, it will most likely be 

near the top, outside corners.

Possible Cures if Spilling Occurs

  The damper should be fully open.

• 

The fireplace opening needs to be reduced by adding a 

drop panel across the top under the lintel.

• 

The air supply from outdoors needs to be increased. Open 

the outside air kit if the appliance is so equipped, or crack 

open a door or window.

  If  necessary,  seek  expert  advice.  Do  not  operate  this 

appliance.

Cleaning

•  Periodic examination and cleaning of the venting system 

of the fireplace should be done before initial use and at 

least annually by a qualified agency.

Fire Risk

Explosion Risk

Inspect external vent cap regularly.

•  Ensure no debris blocks cap.

•  Combustible materials blocking cap may 

ignite.

•  Restricted  air  flow  affects  burner 

operation.

WARNING

Fire Risk

Explosion Risk

Personal Injury Risk

Failure to position the parts in accordance 

with  the  diagrams  provided  with  the  log 

packages  or  failure  to  use  only  parts 

approved with this appliance may result in 

property damage or personal injury.

WARNING

Note: 

If your log set is the burnt-out type, place the rock 

wool  in  the  center  of  the  logs  to  give  a  glowing  ember 

effect.

•  Install the logs using the installation instructions included 

with them.

•  Light the burner as outlined in the operating section. Allow 

the flame pattern to stabilize. If you are satisfied with the 

flame pattern go to the next step. If you want more or less 

flame around the front log, turn off the gas and move the 

grate backward or forward. 

•  Once you are satisfied, turn on the gas and go on to the 

next step.

•  Arrange  the  top  logs  as  shown  in  your  log  set  up 

instructions. Light the burner as outlined in the operating 

instructions and allow the flame to stabilize.

•  Spread the lava rock around the outside of the burner 

pan on the floor of the fireplace. If possible, cover the gas 

connector with the cinders.

Содержание MHK18NG

Страница 1: ...ors and liquids in the vicinity of this or any other appliance What to do if you smell gas Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performe...

Страница 2: ... noted otherwise applies to all models and gas control sys tems Your new gas log set will give you years of durable use and trouble free enjoyment Welcome to the Hearth Home Technologies family of appliance products Listing Label Information Location The model information regarding your specific gas log set can be found on the rating plate Congratulations Homeowner Reference Information Model Name...

Страница 3: ... Left Side Gas Piping 7 C Gas Pressure 8 4 Installation Instructions A Install the Damper Stop 9 B Install the Burner Pan Assembly 9 C Install the Grate 9 D Place Sand and Rockwool 9 E Install the Logs 10 F Adjust the Burner Flame 10 G Inspect the Venting System 10 5 Operating Instructions A Lighting Instructions 11 B Glass Doors 12 C Important Safeguards 12 6 Maintaining and Servicing the Applian...

Страница 4: ...e Technical Services Department at 1 888 427 3973 or 1 800 927 6841 B Table 1 Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or the gas supplier WARNING Fire Risk Exhaust Fumes Risk Do NOT ...

Страница 5: ...equired for installation Pliers Phillips screwdriver Tape measure Crescent wrenches Gas shutoff valve Non corrosive leak check solution 3 4 in wrench 7 16 in wrench Sharp Edges Wear protective gloves and safety glasses during installation CAUTION D Inspect the Appliance and Components Remove the contents from the carton Attached to the burner are tags identifying the manufacturer name serial numbe...

Страница 6: ...r Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water WARNING Inspect appliance and components for damage Damaged parts may impair safe operation Do NOT install damaged components Do NOT install incomplete components Do NOT install substitute components Report damaged parts to dealer W...

Страница 7: ... the gas supply line installed in accordance with local building codes if any If not follow ANSI 223 1 Installation should be done by a qualified installer approved and or licensed as required by the locality In the Common wealth of Massachusetts installation must be performed by a licensed plumber or gas fitter Note A listed and Commonwealth of Massachusetts approved 1 2 in 13 mm T handle manual ...

Страница 8: ...ak Test Make sure the gas connections are tight Turn on the gas and coat each joint with a non corrosive gas leak check solution Air bubbles will form indicating any leaks DO NOT USE A FLAME OR ANY TYPE OF IGNITION SOURCE TO CHECK FOR LEAKS All leaks must be corrected before proceeding with installation The appliance must only be installed in a solid fuel burning fireplace with the flue damper cla...

Страница 9: ...connector to the brass elbow or safety pilot fitting Attach the other end to the brass adapter at the gas tube C Install the Grate The grate should be centered over the burner pan side to side If the grate sits toward the front of the burner pan the flames will be larger coming through the logs If the grate sits toward the back of the burner pan the ember bed will be more prominent Refer to Figure...

Страница 10: ...e Do not operate this appliance Cleaning Periodic examination and cleaning of the venting system of the fireplace should be done before initial use and at least annually by a qualified agency Fire Risk Explosion Risk Inspect external vent cap regularly Ensure no debris blocks cap Combustible materials blocking cap may ignite Restricted air flow affects burner operation WARNING Fire Risk Explosion ...

Страница 11: ...ome gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Do not use this appliance if any part has bee...

Страница 12: ...nd ventilation air is not obstructed front grilles and vent caps Before installing into a solid fuel burning fireplace the chimney and firebox should be inspected and cleaned to remove soot creosote ashes paint bird nests etc Annual examination of the chimney must be performed by a qualified agency to ensure proper ventilation of flue gases created by this appliance Have the chimney and adjacent s...

Страница 13: ...technician recommended Check Condition of doors surrounds and fronts Obstructions of combustion and ventilation air Condition of logs Condition of firebox Gas connections and fittings Obstructions of termination cap Clean Glass Logs Burner burner ports Risk of Fire Delayed ignition or explosion Exposure to combustion fumes Odors WARNING Repair and replacement work should be done by a qualified ser...

Страница 14: ... 2010 14 7 Reference Materials A Replacement Parts Exploded Parts Diagram MHK NG Service Parts Fireside Hearth Kits Beginning Manufacturing Date 8 1 2010 Ending Manufacturing Date Active TM MHK Hearth Kit Assembly 1 MHK Burner Pan Assembly 2 MHK Grate Assembly 3 7 6 5 4 8 ...

Страница 15: ... Burner Pan Assy SRVAGLBP14 SRVAGLBP18 1 2 Grate Assy SRVAG16 SRVAG18 1 3 Orifice BPO 2 26 BPO 2 20 1 4 Connector Tube SRV3814NXN SRV3814NXN 1 5 Damper Stop Assy SRV500 SC SRV500 SC 1 6 Elbow 3 8 MFL x 3 8 FPT Brass 01 1050 01 1050 1 7 Elbow 3 8 Flare x 1 2 FIP Brass 10 1037 10 1037 1 8 Cap 1 2 Malleable Pipe 10 1053 10 1053 1 Sand SRVACC15 SRVACC15 1 Lava Rock SRVACC10 SRVACC10 1 Glowing Embers S...

Страница 16: ...urner Hearth Kits 4004 304 Rev C 08 2010 16 Exploded Parts Diagram STMHK NG Service Parts Fireside Hearth Kits Beginning Manufacturing Date 8 1 2010 Ending Manufacturing Date Active TM 1 STMHK Burner Pan Assembly 2 STMHK Grate 3 4 5 6 7 ...

Страница 17: ...TMHK18NG STMHK24NG Qty 1 Burner Pan Assy SRVOBP18ST SRVOPB20ST 1 2 Grate Assy SRVAG16 SRVAG18 1 3 Orifice BPO 2 26 BPO 2 20 1 4 Connector Tube SRV3814NXN SRV3814NXN 1 5 Damper Stop Assy SRV500 SC SRV500 SC 1 6 Elbow 3 8 MFL x 3 8 FPT Brass 01 1050 01 1050 1 7 Elbow 3 8 Flare x 1 2 FIP Brass 10 1037 10 1037 1 Sand SRVACC15 SRVACC15 1 Lava Rock SRVACC10 SRVACC10 1 Glowing Embers SRVACC12 SRVACC12 1 ...

Страница 18: ...Hearth Home Technologies Fireside Burner Hearth Kits 4004 304 Rev C 08 2010 18 ...

Страница 19: ...Hearth Home Technologies Fireside Burner Hearth Kits 4004 304 Rev C 08 2010 19 ...

Страница 20: ...rns For the number of your nearest Hearth Home Technologies dealer please call 1 800 927 6841 or 1 888 427 3973 NOTES DO NOT DISCARD THIS MANUAL CAUTION Important operating and maintenance instructions included Leave this manual with party responsible for use and operation Read understand and follow these instructions for safe installation and operation D O N O T D I S C A R D TM ...