Hearth & Home Technologies Inc. • Cinch Pipe & Term Caps • 4033-900 Rev K • 05/05
4
Vent depth is measured from the back of the appliance to the outer edge of the exterior wall. See Table 1 and Figure 1.
Figure 1 - Measuring Required Vent Depth
Table 1
TRAP CAP SPECIFICATION CHART
Appliance
DVP-TRAPK1
Top Vent
Depth
DVP-TRAP1
Rear Vent
Depth
DVP-TRAPK2
Top Vent
Depth
DVP-TRAP2
Rear Vent
Depth
Novus
4-1/2 in. to 6-1/4 in.
3-1/2 in. to 4-3/4 in.
7 in. to 11 in.
5-1/2 in. to 9-1/2 in.
NXT
4-1/8 in. to 5-7/8 in.
4-5/8 in. to 6-3/8 in.
6-1/2 in. to 10-1/2 in.
7-1/4 in. to 11-1/4 in.
Caliber
4-1/8 in. to 5-7/8 in.
3-5/8 in. to 5-3/8 in.
6-1/2 in. to 10-1/2 in.
6-1/4 in. to 10-1/4 in.
Maxus
4-1/2 in. to 6-1/4 in.
4-1/8 in. to 5-7/8 in.
6-7/8 in. to 10-7/8 in.
6-3/4 in. to 10-3/4 in.
GNTC50
5 in. to 6-3/4 in.
4-7/8 in. to 6-5/8 in.
7-3/8 in. to 11-3/8 in.
7-3/8 in. to 11-3/8 in.
Designer*
4 in. to 5-3/4 in.
5-3/4 in. to 7-1/2 in.
6-3/8 in. to 10-3/8 in.
8-1/8 in. to 12-1/8 in.
Titan
3-1/2 in. to 5-1/4 in.
N/A
6 in. to 10 in.
N/A
6000
2-3/4 in. to 4-1/2 in.
3-1/8 in. to 4-7/8 in.
5-1/4 in. to 9-1/4 in.
5-5/8 in. to 9-5/8 in.
8000
2-3/4 in. to 4-1/2 in.
3-1/8 in. to 4-7/8 in.
5-1/4 in. to 9-1/4 in.
5-5/8 in. to 9-5/8 in.
Olympian
3-1/2 in. to 5-1/4 in.
N/A
6 in. to 10 in.
N/A
Multisided
7-1/2 in. to 9-1/4 in.
3-1/8 in. to 4-7/8 in.
10 in. to 14 in.
5-5/8 in. to 9-5/8 in.
Gem
4-1/2 in. to 6-1/4 in.
N/A
7 in. to 11 in.
N/A
SL units
N/A
3-1/8 in. to 4-7/8 in.
N/A
5-5/8 in. to 9-5/8 in.
ICON
3-1/2 in. to 5-1/4 in.
N/A
6-1/2 in. to 10-1/2 in.
N/A
GDST5244I**
4 in. to 5-3/4 in.
N/A
6-3/4 in. to 7-3/4 in.
N/A
* Top vented appliance - Designer needs a DVP12 after the elbow.
** GDST5244I requires a DVP12 and DVP6 after the elbow.