Hearth & Home Technologies • B36S-AU Installation Manual • 2563-980 • 10/19
V
1
Figure 4.14
Figure 4.13
V
1
= 60 ft. Max. (18.3 m)
Top Vent - Vertical Termination
No Elbows
EXHAUST BAFFLE
Top Vent Application
Rear Vent Application
Exhaust restrictors are recommended for these verti-
cally terminated products which have excessive draft.
Exhaust restrictors will compensate for high draft, and
restore visual flame height. If the vent configuration has
a total vertical of 15-60 ft. (4.6-18.3 m), an exhaust re-
strictor may be needed. The exhaust restrictor can be
located in the appliance manual bag.
Note
: Be sure to rein-
stall the exhaust baffle
after exhaust restrictor
installation.
Exhaust restrictor
Exhaust restrictor
Exhaust restrictor Instructions
1. Install the exhaust restrictor over the center of the ex-
haust outlet in the firebox. See Figure 4.14.
2. Center the exhaust restrictor in the open end of the
exhaust outlet and secure through the slots on the ex-
haust restrictor with the two (2) 1/4 in. (12 mm) self-
tapping screws provided in the appliance manual bag.
To access the exhaust
openings, remove the
exhaust baffle. To re
-
move exhaust baffle, re
-
move the two wing nuts.
Note:
If installing a vertical vent/termination off the top of
the appliance, the optional vertical termination baffle may
be needed.
Note: Use SLP Series
components only.