Healthy Climate Solutions HEPA-20 Скачать руководство пользователя страница 6

6

 Operation

 Maintenance

1.

  Make sure that the unit is plugged into a grounded outlet (120 Volt, 60 Hz).

2.

  For optimum performance, the HEPA system should operate when the indoor air handler/furnace blower is  

 

on.  An optional air handler/furnace blower interlock kit can be ordered for ‘cycled’ operation.  (see  

 

Replacement Parts)

3.

  Turn the unit on by pressing the on/off switch to the ‘1’ position.  The switch should light up when the unit is  

 

on.

4.

  To turn the unit off, press the on/off switch to the ‘0’ position.  The switch light should turn off when the unit  

 

is off.

Proper care and maintenance of your HEPA system 

will ensure years of service.  The unit must be turned 

off during service/maintenance or when filters are 

being changed.

It is recommended that gloves and a filtered 

breathing mask be worn during filter replacement.

Filter Change Schedule

Note:

  Failure to properly maintain your HEPA system 

will decrease the efficiency and air flow.

For enhanced odor control, the Coconut Shell Carbon 

Canister provides up to one year of odor capture.

Carbon Pre-Filter:

 12 months

HEPA Filter:

 2 to 5 years

Inner Charcoal Filter:

 3 months

Optional Coconut Shell Carbon Canister:

 1 year

NOTE: Filter life is based on average air content.  Some 

filters may need to be changed more often due to higher 

amounts of dust, humidity, or chemicals found in your 

ambient air.  Additionally, people who are more sensitive 

to these air borne contaminates may desire more fre-

quent filter changes.

Filter Changing Guidelines

Carbon Pre-Filter:

Dust and other large particles will collect on the car-

bon pre-filter over time.  The color of the filter will 

change as particulates build up on the carbon pre-filter.  

Change the carbon pre-filter when you can see the par-

ticulate build up start to clog up the carbon pre-filter.

HEPA Filter:

As the HEPA filter captures particulates, it will darken 

over time.  Replace the HEPA filter when it darkens to 

the level seen in example D.

Inner Charcoal Filter:

The inner charcoal filter will rarely look used.  This fil-

ter captures odors and gasses, yet the filter’s appear-

ance will not change.  When this filter has reached 

it’s maximum adsorbancy of odors and gasses, it will 

no longer work.  Replace this filter when it no longer 

seems to capture odors, at least every 3 months, 

whichever occurs first.

A. New

B. Used

C. Used

D. Replace

Risk of Sharp Edges Hazard.

Equipment sharp edges can cause injuries.
Avoid grasping equipment edges without protective 

gloves.

!

CAUTION

Electrical Shock Hazard.

Can cause injury or death.
Disconnect all electrical power supplies 

before servicing.
Do not operate equipment without 

access panels in place

!

WARNING

Carbon Pre-Filter

HEPA Filter

Inner Charcoal Filter

Figure 12.

Optional Coconut Shell 

Carbon Canister

replaces Inner Charcoal Filter

Содержание HEPA-20

Страница 1: ...aware of your indoor air quality situation and be familiar with your heating ventilation and air conditioning equipment 4 Remove HEPA cartridge packing materials before initial start up of this produc...

Страница 2: ...ay shorten the life of the carbon canister Under normal conditions the carbon canister will last up to 6 months Initially the HEPA filter s particulate removal efficiency improves with use However the...

Страница 3: ...and odors from the air OPTIONAL UPGRADE The stage 3 Inner Carbon Filter may be replaced by an optional heavy duty granulated coconut shell carbon canister The VOC Canister offers increased capacity r...

Страница 4: ...abinet Filter Section Optional Coconut Shell Carbon Canister HEPA Cartridge Parts figure 1 figure 3 figure 4 figure 2 Motor Impeller Filter Adapter threaded O Ring Specifications HEPA 20 HEPA 40 HEPA...

Страница 5: ...1 75 410 718 254 203 44 HEPA 60 16 13 28 25 10 0 8 0 1 75 410 718 254 203 44 F G H I J HEPA 20 2 0 1 0 9 0 15 25 1 4 51 25 229 387 36 HEPA 40 6 5 1 0 11 0 17 875 1 875 165 25 279 454 48 HEPA 60 6 5 1...

Страница 6: ...s of dust humidity or chemicals found in your ambient air Additionally people who are more sensitive to these air borne contaminates may desire more fre quent filter changes Filter Changing Guidelines...

Страница 7: ...other end of the clip once the carbon pre filter is stretched tight to lock the clip into place as shown in figure 15 Release clip it should hold tight on both ends of the carbon pre filter keeping it...

Страница 8: ...an cause injury or death Disconnect all electrical power supplies before servicing Do no operate equipment without access panels in place Do not use this fan with any solid state speed control device...

Страница 9: ...irectly into the return air elbow of the main return To reduce static pressure install outlet with a 45 degree takeoff directly up line from the return air elbow If the unit is being installed indepen...

Страница 10: ...s should be as straight as possible if the duct runs are too long reduced CFM may result If duct is exposed to unconditioned air externally insulated flex duct is highly recommended Externally insulat...

Страница 11: ...ers are recommended to help distribute airflow evenly in the occupied space Ducting If HEPA system is installed where inlet and outlet collars face down metal elbows must be connected to both inlet an...

Страница 12: ...8 15 for optimal VOC Aldehyde removal Other Recommeded HEALTHY CLIMATE Products Ventilation Control System LVCS X4141 Humiditrol Whole Home Dehumidification Systems EDA 024B 94M41 EDA 036C 94M42 EDA 0...