13
DEH W/AC
90-1854
To allow dehumidification
during active air
conditioning, select
ENABLED and press
MODE.
90-1854
To disable dehumidification
when the air conditioning is
on, select DISABLED and
Press MODE.
RH OFFSET
90-1854
An offset can be
applied to the on-board
humidity reading to avoid
discrepancies with other
humidity measuring devices
in the home. Use the UP/
DOWN arrows to select
an offset from -5% to 5%.
Press MODE to exit the
installer set-up screens.
ZONE
90-1854
If installing the dehumidifier
in a single zone application,
select DISABLED and
press MODE to go to the
EXTERNAL control screen
selections.
90-1854
If installing the dehumidifier
in a two-zone application,
use the UP or DOWN
arrows to select ENABLED
and press MODE to go to
the EXTERNAL control
screen selections.
EXTERNAL CONTROL
90-1854
If using the dehumidifier
on-board control select
DISABLED and press
MODE to go to the
dehumidification with air
conditioning (DEH W/AC)
screen selections.
90-1854
If using an iComfort
®
Thermostat or a Y6456 as
an external control or other
third-party external control,
such as a thermostat with
dehumidifier outputs, use
the UP or DOWN arrows
to select ENABLED and
press MODE to go to the
dehumidification with air
conditioning (DEH W/AC)
screen selections.